SsangYong Korando III (2010 year). Manual — part 130
14-12
Specified value
below 0.05A
Setting up the tester
▶
Preparation
▶
Disconnect the negative cable from the
battery.
Set up the ammeter and MSM as shown in
the figure above.
1.
2.
2) When Using MSM
Connect the negative cable to the
battery.
3.
Make sure to set up the tester while keeping
its polarity.
Measure the current while removing the fuses
one by one. If the current drops sharply when
a certain fuse is removed, inspect the affected
circuit.
14-13
0000-00
Specified
value
over 11V: Normal
9 ~ 11V: Charging required
below: 9V: Over discharged,
battery replacement required
7. INSPECTION - BATTERY
Perform the basic inspection (all electric devices OFF).
-
Battery tester
1) Voltage Check (without load)
Connect one measuring clamp to “+”
terminal of battery first, then connect the
other one to “-“terminal. (Disconnect the
clamps in the reverse order).
1.
Read the measurement.
2.
14-14
2) Voltage Check (with load)
1
Push the load switch to ON (to arrow
direction) direction for less than 5 seconds.
1.
Read the measurement.
2.
Specified
value
7 ~ 9V (Red): Over discharged
or faulty
9 ~ 11V (Yellow): Charging
required
11 ~ 13V: Normal
To identify the battery capacity with the
voltage drop (V) value, discharge the fixed
load capacity (120A) for a certain period (5
seconds).
14-15
0000-00
8. DTC SETTING CONDITIONS
Charge warning lamp ON condition
▶
Turn the ignition ON (Engine stopped)
Open or short circuit of L terminal wiring, open or short internal circuit of alternator (fixed control of
13.8V)
Open or short circuit of F terminal wiring, no feedback output signal
1.
2.
3.