SsangYong Rexton. Manual — part 95
DI09-6
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
ELECTRIC DEVICES AND SENSORS
DI ENG SM - 2004.4
CIRCUIT DIAGRAM OF PREHEATING SYSTEM
Y220_09003
DI09-7
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
ELECTRIC DEVICES AND SENSORS
DI ENG SM - 2004.4
CIRCUIT DIAGRAM OF STARTING AND ALTERNATOR
Y220_09004
DI09-8
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
ELECTRIC DEVICES AND SENSORS
DI ENG SM - 2004.4
TROUBLE DIAGNOSIS
GENERAL
Correction
• Charging the battery or replace
the battery.
• Repair or replace the battery
cable.
• Repair or replace the starter
motor/starter motor circuit.
• Replace the ignition switch.
• Repair the ground short.
• Charging the battery or replace
the battery.
• Repair or replace the battery
cable.
• Repair or replace the starter
motor.
• Repair or replace the starter
motor.
• Replace the ignition switch.
• Replace the starter motor.
• Replace the flywheel.
• Repair the open circuit.
• Adjust the belt tension or replace
the belt.
• Repair the open or a short circuit.
• Replace the battery.
• Repair the open ground circuit.
• Repair or replace the charging
indicator lamp/fuse.
• Replace the ignition switch.
• Repair the circuit.
• Repair or replace the battery
cable.
• Adjust the belt tension or replace
the belt.
• Repair the wiring harness.
• Replace generator
• Repair wiring
Condition
No crank
Probable Cause
• Low battery voltage.
• Battery cable is loose,
corroded, or damaged.
• Faulty starter motor or starter
motor circuit is open.
• Faulty ignition switch.
• Ground short.
• Low battery voltage.
• Battery.
• Battery cables are loose,
corroded, or damaged.
• Faulty starter motor.
• Faulty starter motor.
• Faulty ignition switch.
• Broken the clutch pinion gear or
faulty starter motor.
• Broken the flywheel ring gear.
• Connected circuit is open.
• Loosen the generator drive belt.
• The circuit is open or a short.
• Battery run down.
• Open ground circuit.
• Charging indicator lamp is blown
or fuse is blown.
• Faulty ignition switch.
• Generator ground circuit is open
or a short.
• Battery cable is corroded or
damaged.
• Loosen the generator drive belt.
• Faulty wiring harness.
• Generator voltage regulator faulty
• Voltage detecfing wiring faulty
Charging indicator lamp does not
put out lights after starting the
engine
Crank ok, but too slow
Starter motor does not stop
Starter motor running, but not
cranking
Battery discharge
Charging indicator lamp does not
work when the ignition switch on
(engine does not work)
Battery over charging
DI09-9
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
ELECTRIC DEVICES AND SENSORS
DI ENG SM - 2004.4
Action
• Replace ignition coil
• Replace distribator (or sensor)
• Replace spark plug or adjust
clearance
• Resetting valve timing
• Replace spark plug or adjust
clearance
• Replace ignition coil
• Resetting valve timing
• Resetting valve timing
Symptom
Hard engine starting
Cause
• Ignition coil faulty
• Distributor (including optical
sensor) faulty
• Spark plug malfuntion
• Ignition timing faulty (spark plug
light is normal)
• Spark plug malfunction
• Ignition coil faulty
• Ignition timing faulty
• Ignition timing faulty
Unstable engine idling
Enging acceralation malfunction