Isuzu D-Max / Isuzu Rodeo (TFR/TFS). Manual — part 1747
DIAGNOSIS 7A2-39
•
Sensor wire open circuit or short circuit to ground between turbine speed sensor terminal 2 and power supply
circuit.
•
Sensor wire open circuit or short circuit to battery between turbine speed sensor terminal 3 and ground circuit.
•
Poor connection of each connector.
Reference:
When the vehicle speed 20km/h at L range in 1st gear, following signal is outputted.
Measurement terminal: B3 (C95) and B5 (C95)
-AC range by circuit tester: Approximately 6.2 V
Turbine Sensor Reference Wave Form
Measurement Terminal: B3 (+)
B5 (-)
Measurement Scale: 5V/div
500ms/div
Measurement Condition: Vehicle speed 20km/h at L range in 1st gear
7A2-40 DIAGNOSIS
DTC P0710 (Flash Code 15) ATF Temperature Sensor Failure
ATF
Temp.
Sensor
TCM
B4 (+)
B14 (-)
H23
(8)
(3)
C95
(4)
(14)
BLU
Terminal
Assembly
BLU/BLK
E54
(2)
(8)
BLU
BLU/BLK
Setting Condition:
•
The condition in which the voltage of oil temperature sensor is below 0.1V (146
°
C) and ATF temperature
warning lamp ON in the P or N range lasts for more than 5 minutes.
Or
•
The vehicle speed exceeds 20 km/h and the voltage of oil temperature sensor exceeds 2.43V (-40
°
C) for more
than 10 seconds.
Fail Safe:
•
The lock-up is inhibited, and TCM is controlled ATF temperature 80
°
C condition as substitute.
•
When the engine speed is more than 470 rpm for 10 minuets, the lock-up and gear shift to 4th (over-drive) are
allowed.
Possible Cause:
•
Oil temperature sensor wire open circuit or short circuit.
•
Oil temperature sensor malfunction.
•
Power supply wire open circuit, short circuit to battery or short circuit to ground between oil temperature sensor
and TCM terminal B4 (C95).
•
Ground wire open circuit or short circuit to battery between oil temperature sensor terminal and TCM terminal
B14 (C95).
DIAGNOSIS 7A2-41
•
Poor connection of each connector.
Reference:
Following output voltage and resistance can be measured by circuit tester.
Measurement terminal: B4 (C95) and B14 (C95)
Temperature
Output Voltage (V)
Resistance
20
°
C
1.55
2,500
Ω
°
C
1.08
1,160
Ω
60
°
C
0.7
590
Ω
7A2-42 DIAGNOSIS
DTC P0560 (Flash Code 16) System Voltage Failure
TCM
A1 (+B)
B5
B15
H23
(15)
C95
(5)
(15)
BLK/YEL
BLK
BLK
Battery
C94
(1)
BLK
Setting Condition:
•
The supply voltage is below 10V and the engine speed exceeds 1000 rpm for more than 1 second.
Fail Safe:
•
When the vehicle is running, the gear position selected at the trouble detection is held and the lock-up is
inhibited.
•
After the vehicle stopped, all solenoid operations stop (OFF) and the gear is fixed to the 3rd. (In case of fail-safe
valve failure, gear shift to 4th (over-drive) is inhibited.)
Possible Cause:
•
Alternator or battery malfunction.
•
Power supply wire open circuit or short circuit to ground between power supply and TCM terminal A1 (C94).
•
Ground wire open circuit or short circuit to battery between ground location and TCM terminal B5 (C95) or B15
(C95).
•
Poor connection of each connector.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.