Isuzu D-Max / Isuzu Rodeo (TFR/TFS). Manual — part 1655
1-6 HEATING AND AIR CONDITIONING
WIRING HARNESS TERMINAL POSITIONS
HEATING AND AIR CONDITIONING 1-7
VENTILATION
VENT MODE
BI
⋅
LEVEL MODE
FOOT MODE
DEF/FOOT MODE
DEF MODE
1-8 HEATING AND AIR CONDITIONING
MAIN DATA AND SPECIFICATIONS
AIR COMPRESSOR
Type
6 cylinder swash plate type
Displacement
cc (lmp fl oz)
147 (4.2)
Oil type
ZXL-100PG
(ISUZU PART NO. 8-97101-338-0)
Oil capacity
cc (lmp fl oz)
150 (4.2)
Magnetic clutch
Type: Dry double disc dia. 135 mm (5.3 in.) (Gasoline)
125 mm (4.9 in.) (4J engine)
HEATING UNIT
Type
Air mix type
Core dimension
mm (in.)
(L
×
H
×
W) 161 (6.34)
×
163 (6.42)
×
45 (1.77)
Capacity
(kcal./hr.)
3700 kcal./hr. (280 m
3
/hr.)
BLOWER UNIT
Type
Sirocco fan type
COOLING UNIT
Type
Fin and tube evaporator
Evaporator element dimensions
mm (in.)
(L
×
H
×
W) 235 (9.25)
×
224 (8.82)
×
74 (2.91)
Evaporator capacity
(kcal./hr.)
4200 kcal./hr. (470 m
3
/hr.)
CONDENSER
Type
Aluminium louvered fins
Capacity
(kcal./hr.)
9400 kcal./hr.
RECEIVER-DEHYDRATOR
Assembly includes sight glass
and temperature sensitive device
REFRIGERANT
Type: R-133a Capacity: 0.65 kg (1.43 lbs.)
IDLE SPEED-UP CONTROL
Idle speed controlled by solenoid switch
HEATING AND AIR CONDITIONING 1-9
SPECIAL PARTS FIXING NUTS AND BOLTS
COMPRESSOR ASSEMBLY
N
⋅
m (kgf
⋅
m/lb
⋅
ft)