Isuzu Amigo / Axiom / Trooper / Rodeo / VehiCross. Manual — part 1399
6E2–47
RODEO 6VD1 3.2L ENGINE DRIVEABILITY AND EMISSIONS
11. Turn on Air Conditioning.
060RY00094
12. Turn “On” and “Off” A/C Switch.
13. Contol A/C Clutch Relay and check data list.
14. If the data list changes, the Fuel Pump Relay is
normal.
EVAP Test
This test is conducted to check EVAP system for its power
operation.
Tech 2 must be used for this test.
Test Procedure:
1. Connect Tech 2 to the vehicle DLC.
2. Run the Engine at idle.
3. Select F3: Miscellaneous Test in the Application
Menu.
060R100078
4. Select F2: EVAP Test in the Miscellaneous Test.
060RY00082
5. Select F0: Purge Solenoid.
060RX025
6E2–48
RODEO 6VD1 3.2L ENGINE DRIVEABILITY AND EMISSIONS
6. Push “Decrease” or “Increase” soft key.
060RY00095
7. Control EVAP Purge Solenoid and check a data list.
8. If the data list changes, the Purge Solenoid is normal.
9. Turn engine off, turn ignition SW “On”.
10. Select F1:EVAP Vent Solenoid.
060RX025
11. Push “On” or “Off” soft key.
060RY00096
12. Control EVAP Vent Solenoid and check data list.
13. If the data list changes, the EVAP Vent Solenoid is
normal.
Fuel System Test
This test is conducted check Fuel system for proper
operation.
Tech 2 must be used for this test.
Test Procedure:
1. Connect Tech 2 to the vehicle DLC.
2. Ignition SW is “On”.
3. Select F3: Miscellaneous Test in the Application
Menu.
060R100078
6E2–49
RODEO 6VD1 3.2L ENGINE DRIVEABILITY AND EMISSIONS
4. Select F3: Fuel System in the Miscellaneous Menu.
060RY00083
5. Select F0: Fuel Trim Enable.
060R200071
6. Push “Disable” or “Enable” soft key.
060RY00097
7. Control Fuel Trim and check data list.
8. If data list changes, the Fuel Trim is normal.
9. Select F1: Fuel Trim Reset.
060R200071
6E2–50
RODEO 6VD1 3.2L ENGINE DRIVEABILITY AND EMISSIONS
10. Push “Reset” soft key.
060RY00098
11. Select F2: O2-Loop status.
060R200071
12. This test is check the “Closed Loop Status”
performance.
13. Push “Open Loop” or “Closed Loop” soft key.
060RY00099
14. Control O2-Loop and check data list.
15. If data list changes, the O2-Loop is normal.
Instruments Test
This test is conducted check Instruments for proper
operation.
Tech 2 must be used for this test.
Test Procedure:
1. Connect Tech 2 to the vehicle DLC.
2. Ignition SW is “On”.
3. Select F3: Miscellaneous Test in the Application
Menu.
060R100078