Nissan Almera Tino V10. Manual — part 345
EC-206
[QG (WITH EURO-OBD)]
DTC P0132, P0152 HO2S1 (A/T MODELS)
5.
Touch “RECORD” on CONSULT-II screen.
6.
Check the following.
●
“HO2S1 MNTR (B1)/(B2)” in “DATA MONITOR” mode
changes from “RICH” to “LEAN” to “RICH” more than 5 times
in 10 seconds.
5 times (cycles) are counted as shown at right.
●
“HO2S1 (B1)/(B2)” voltage goes above 0.6V at least once.
●
“HO2S1 (B1)/(B2)” voltage goes below 0.3V at least once.
●
“HO2S1 (B1)/(B2)” voltage never exceeds 1.0V.
CAUTION:
●
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
●
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Without CONSULT-II
1.
Start engine and warm it up to normal operating temperature.
2.
Set voltmeter probes between ECM terminal 35 [HO2S1 (B1) signal] or 36 [HO2S1 (B2) signal] and
engine ground.
3.
Check the following with engine speed held at 2,000 rpm con-
stant under no load.
●
The voltage fluctuates between 0 to 0.3V and 0.6 to 1.0V
more than 5 times within 10 seconds.
●
The maximum voltage is over 0.6V at least one time.
●
The minimum voltage is below 0.3V at least one time.
●
The voltage never exceeds 1.0V.
1 time: 0 - 0.3V
→
0.6 - 1.0V
→
0 - 0.3V
2 times: 0 - 0.3V
→
0.6 - 1.0V
→
0 - 0.3V
→
0.6 - 1.0V
CAUTION:
●
Discard any heated oxygen sensor which has been dropped
from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new
one.
SEF646Y
SEF647Y
SEF648Y
MBIB0019E
DTC P0132, P0152 HO2S1 (A/T MODELS)
EC-207
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
M
A
EC
●
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Removal and Installation
EBS00QJO
HEATED OXYGEN SENSOR 1
Refer to
EM-21, "EXHAUST MANIFOLD AND CATALYTIC CONVERTER"
.
EC-208
[QG (WITH EURO-OBD)]
DTC P0133 HO2S1 (M/T MODELS)
DTC P0133 HO2S1 (M/T MODELS)
PFP:22690
Component Description
EBS00QJP
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 has a closed-end tube
made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions. The
heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts
the injection pulse duration to achieve the ideal air-fuel ratio. The
ideal air-fuel ratio occurs near the radical change from 1V to 0V.
CONSULT-II Reference Value in Data Monitor Mode
EBS00QJQ
Specification data are reference values.
On Board Diagnosis Logic
EBS00QJR
To judge the malfunction of heated oxygen sensor 1, this diagnosis
measures response time of heated oxygen sensor 1 signal. The time
is compensated by engine operating (speed and load), fuel feedback
control constant, and heated oxygen sensor 1 temperature index.
Judgment is based on whether the compensated time (heated oxy-
gen sensor 1 cycling time index) is inordinately long or not.
SEF463R
SEF288D
MONITOR ITEM
CONDITION
SPECIFICATION
HO2S1 (B1)
●
Engine: After warming up
Maintaining engine speed at 2,000
rpm
0 - 0.3V
←→
Approx. 0.6 - 1.0V
HO2S1 MNTR (B1)
LEAN
←→
RICH
Changes more than 5 times dur-
ing 10 seconds.
SEF010V
DTC P0133 HO2S1 (M/T MODELS)
EC-209
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
M
A
EC
DTC Confirmation Procedure
EBS00QJS
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If “DTC Confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
●
Always perform at a temperature above
−
10
°
C (14
°
F).
●
Before performing the following procedure, confirm that battery voltage is more than 11V at idle.
WITH CONSULT-II
1.
Start engine and warm it up to normal operating temperature.
2.
Stop engine and wait at least 10 seconds.
3.
Turn ignition switch “ON” and select “HO2S1 (B1) P0133” of “HO2S1” in “DTC WORK SUPPORT” mode
with CONSULT-II.
4.
Touch “START”.
5.
Start engine and let it idle for at least 3 minutes.
NOTE:
Never raise engine speed above 3,600 rpm after this step. If
the engine speed limit is exceeded, return to step 5.
6.
When the following conditions are met, “TESTING” will be dis-
played on the CONSULT-II screen. Maintain the conditions con-
tinuously until “TESTING” changes to “COMPLETED”. (It will
take approximately 20 to 50 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from
step 2.
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0133
0133
Heated oxygen sensor 1
circuit slow response
The response of the voltage signal from the
sensor takes more than the specified time.
●
Harness or connectors
(The sensor circuit is open or shorted.)
●
Heated oxygen sensor 1
●
Fuel pressure
●
Injectors
●
Intake air leaks
●
Exhaust gas leaks
●
PCV valve
●
Mass air flow sensor
SEF338Z
ENG SPEED
2,100 - 3,100 rpm
Vehicle speed
More than 80 km/h (50 MPH)
B/FUEL SCHDL
3.8 - 7.6 msec
Selector lever
Suitable position
SEF339Z