Nissan Almera Tino V10. Manual — part 823
COMBINATION METER CIRCUIT CHECK
=NLEL0676S09
1
CHECK CONNECTOR
1. Turn ignition switch OFF.
2. Disconnect the negative battery cable.
3. Check following terminals and connector of combination meter for damage, bend and loose connection (meter side and
harness side).
OK or NG
OK
©
GO TO 2.
NG
©
Repair terminal or connector.
2
CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect combination meter connector.
2. Check resistance between combination meter harness connector M84 terminals 39 (L) and 40 (R).
YEL425E
OK or NG
OK
©
Replace combination meter.
NG
©
Repair harness between combination meter and data link connector.
CAN SYSTEM (TYPE 6)
Trouble Diagnoses (Cont’d)
EL-588
CAN COMMUNICATION CIRCUIT CHECK
=NLEL0676S10
1
CHECK CONNECTOR
1. Turn ignition switch OFF.
2. Disconnect the negative battery cable.
3. Check following terminals and connector of combination meter for damage, bend and loose connection (meter side,
control unit side, control module side and harness side).
I
Combination meter
I
Smart entrance control unit
I
ECM
I
ABS actuator and electric unit (control unit)
I
Between ECM and data link connector
OK or NG
OK
©
GO TO 2.
NG
©
Repair terminal or connector.
2
CHECK HARNESS FOR SHORT CIRCUIT
1. Disconnect combination meter connector, smart entrance control unit connector and harness connector M82 (LHD mod-
els) or harness connector M80 (RHD models).
2. Check continuity between data link connector M6 terminals 6 (L) and 3 (R).
SEL816Y
OK or NG
OK
©
GO TO 3.
NG
©
I
Repair harness between data link connector and harness connector M82 (LHD mod-
els).
I
Repair harness between data link connector and harness connector M80 (RHD mod-
els).
I
Repair harness between data link connector and smart entrance control unit.
I
Repair harness between data link connector and combination meter.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
CAN SYSTEM (TYPE 6)
Trouble Diagnoses (Cont’d)
EL-589
3
CHECK HARNESS FOR SHORT CIRCUIT
Check continuity between data link connector M6 terminals 6 (L), 3 (R) and ground.
SEL817Y
OK or NG
OK
©
GO TO 4.
NG
©
I
Repair harness between data link connector and harness connector M82 (LHD mod-
els).
I
Repair harness between data link connector and harness connector M80 (RHD mod-
els).
I
Repair harness between data link connector and smart entrance control unit.
I
Repair harness between data link connector and combination meter.
4
CHECK HARNESS FOR SHORT CIRCUIT
1. Disconnect ECM connector and harness connector M11 (LHD models) or harness connector M80 (RHD models).
2. Check continuity between ECM harness connector M107 terminals 95 (L) and 87 (R).
YEL439E
OK or NG
OK
©
GO TO 5.
NG
©
I
Repair harness between ECM and harness connector M11 (LHD models).
I
Repair harness between ECM and harness connector M80 (RHD models).
CAN SYSTEM (TYPE 6)
Trouble Diagnoses (Cont’d)
EL-590
5
CHECK HARNESS FOR SHORT CIRCUIT
Check continuity between ECM harness connector M112 terminals 95 (L), 87 (R) and ground.
YEL440E
OK or NG
OK
©
GO TO 6.
NG
©
I
Repair harness between ECM and harness connector M11 (LHD models).
I
Repair harness between ECM and harness connector M80 (RHD models).
6
CHECK HARNESS FOR SHORT CIRCUIT
1. Disconnect harness connector ABS actuator and electric unit (control unit).
2. Check continuity between ABS actuator and electric unit (control unit) harness connector E142 terminals 26 (L) and 15
(R).
YEL455E
OK or NG
OK
©
GO TO 7.
NG
©
I
Repair harness between ABS actuator and electric unit (control unit) and harness con-
nector E125. (LHD models)
I
Repair harness between ABS actuator and electric unit (control unit) and harness con-
nector E106. (LHD models)
I
Repair harness between ABS actuator and electric unit (control unit) and harness con-
nector E145. (RHD models)
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
CAN SYSTEM (TYPE 6)
Trouble Diagnoses (Cont’d)
EL-591
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст