Nissan Murano Z51. Manual — part 550
EC-208
< DTC/CIRCUIT DIAGNOSIS >
[VQ35DE]
P0138, P0158 HO2S2
2.
Perform DTC confirmation procedure again.
>> GO TO 3.
5.
PERFORM COMPONENT FUNCTION CHECK FOR MALFUNCTION B
Perform component function check. Refer to
EC-208, "Component Function Check"
NOTE:
Use component function check to check the overall function of the heated oxygen sensor 2 circuit. During this
check, a 1st trip DTC might not be confirmed.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Go to
Component Function Check
INFOID:0000000005536614
1.
PERFORM COMPONENT FUNCTION CHECK-I
Without CONSULT-III
1.
Start engine and warm it up to the normal operating temperature.
2.
Turn ignition switch OFF and wait at least 10 seconds.
3.
Turn ignition switch ON.
4.
Turn ignition switch OFF and wait at least 10 seconds.
5.
Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
6.
Let engine idle for 1 minute.
7.
Check the voltage between ECM harness connector terminals under the following conditions.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 2.
2.
PERFORM COMPONENT FUNCTION CHECK-II
Check the voltage between ECM harness connector terminals under the following conditions.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 3.
3.
PERFORM COMPONENT FUNCTION CHECK-III
DTC
ECM
Condition
Voltage
Connec-
tor
+
–
Terminal
Terminal
P0138
F8
33
[HO2S2 (bank 1)
signal]
35
(Sensor
ground)
Revving up to 4,000 rpm under no
load at least 10 times
The voltage should be below 0.18 V
at least once during this procedure.
P0158
34
[HO2S2 (bank 2)
signal]
DTC
ECM
Condition
Voltage
Connec-
tor
+
–
Terminal
Terminal
P0138
F8
33
[HO2S2 (bank 1)
signal]
35
(Sensor
ground)
Keeping engine speed at idle for 10
minutes
The voltage should be below 0.18 V
at least once during this procedure.
P0158
34
[HO2S2 (bank 2)
signal]
P0138, P0158 HO2S2
EC-209
< DTC/CIRCUIT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
Check the voltage between ECM harness connector terminals under the following conditions.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Go to
Diagnosis Procedure
INFOID:0000000005536615
1.
INSPECTION START
Confirm the detected malfunction (A or B). Refer to
.
Which malfunction is detected?
A
>> GO TO 2.
B
>> GO TO 9.
2.
CHECK GROUND CONNECTION
1.
Turn ignition switch OFF.
2.
Check ground connection E38. Refer to Ground Inspection in
.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace ground connection.
3.
CHECK HO2S2 CONNECTOR FOR WATER
1.
Disconnect heated oxygen sensor 2 harness connector.
2.
Check that water is not inside connectors.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness or connectors.
4.
CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
1.
Disconnect heated oxygen sensor 2 harness connector.
2.
Disconnect ECM harness connector.
3.
Check the continuity between heated oxygen sensor 2 (HO2S2) harness connector and ECM harness
connector.
4.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair open circuit, short to ground or short to power in harness or connectors.
5.
CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Check the continuity between HO2S2 harness connector and ECM harness connector.
DTC
ECM
Condition
Voltage
Connec-
tor
+
–
Terminal
Terminal
P0138
F8
33
[HO2S2 (bank 1)
signal]
35
(Sensor
ground)
Coasting from 80 km/h (50 MPH)
with selector lever in the D position
The voltage should be below 0.18 V
at least once during this procedure.
P0158
34
[HO2S2 (bank 2)
signal]
DTC
HO2S2
ECM
Continuity
Bank
Connector
Terminal
Connector
Terminal
P0138
1
F70
1
F8
35
Existed
P0158
2
F71
1
EC-210
< DTC/CIRCUIT DIAGNOSIS >
[VQ35DE]
P0138, P0158 HO2S2
2.
Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and
ground.
3.
Also check harness for short to power.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Repair open circuit, short to ground or short to power in harness or connectors.
6.
CHECK HEATED OXYGEN SENSOR 2
EC-212, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 8.
NO
>> GO TO 7.
7.
REPLACE HEATED OXYGEN SENSOR 2
Replace malfunctioning heated oxygen sensor 2.
CAUTION:
• Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
• Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner [commercial service tool (J-43897-18 or J-43897-12)] and approved anti-seize lubricant
(commercial service tool).
>> INSPECTION END
8.
CHECK INTERMITTENT INCIDENT
GI-39, "Intermittent Incident"
>> INSPECTION END
9.
CHECK GROUND CONNECTION
1.
Turn ignition switch OFF.
2.
Check ground connection E38. Refer to Ground Inspection in
.
Is the inspection result normal?
YES
>> GO TO 10.
NO
>> Repair or replace ground connection.
10.
CLEAR MIXTURE RATIO SELF-LEARNING VALUE
DTC
HO2S2
ECM
Continuity
Bank
Connector
Terminal
Connector
Terminal
P0138
1
F70
4
F8
33
Existed
P0158
2
F71
4
34
DTC
HO2S2
Ground
Continuity
Bank
Connector
Terminal
P0138
1
F70
4
Ground
Not existed
P0158
2
F71
4
DTC
ECM
Ground
Continuity
Connector
Terminal
P0138
F8
33
Ground
Not existed
P0158
34
P0138, P0158 HO2S2
EC-211
< DTC/CIRCUIT DIAGNOSIS >
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
1.
Clear the mixture ratio self-learning value. Refer to
EC-20, "MIXTURE RATIO SELF-LEARNING VALUE
CLEAR : Special Repair Requirement"
.
2.
Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0172 or P0175 detected? Is it difficult to start engine?
YES
>> Perform trouble diagnosis for DTC P0172, P0175. Refer to
NO
>> GO TO 11.
11.
CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect heated oxygen sensor 2 harness connector.
3.
Disconnect ECM harness connector.
4.
Check the continuity between HO2S2 harness connector and ECM harness connector.
5.
Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
>> GO TO 12.
NO
>> Repair open circuit, short to ground or short to power in harness or connectors.
12.
CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1.
Check the continuity between HO2S2 harness connector and ECM harness connector.
2.
Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and
ground.
3.
Also check harness for short to power.
Is the inspection result normal?
YES
>> GO TO 13.
NO
>> Repair open circuit, short to ground or short to power in harness or connectors.
13.
CHECK HEATED OXYGEN SENSOR 2
EC-212, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 15.
NO
>> GO TO 14.
DTC
HO2S2
ECM
Continuity
Bank
Connector
Terminal
Connector
Terminal
P0138
1
F70
1
F8
35
Existed
P0158
2
F71
1
DTC
HO2S2
ECM
Continuity
Bank
Connector
Terminal
Connector
Terminal
P0138
1
F70
4
F8
33
Existed
P0158
2
F71
4
34
DTC
HO2S2
Ground
Continuity
Bank
Connector
Terminal
P0138
1
F70
4
Ground
Not existed
P0158
2
F71
4
DTC
ECM
Ground
Continuity
Connector
Terminal
P0138
F8
33
Ground
Not existed
P0158
34
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.