Nissan Murano Z51. Manual — part 1127
PWC-3
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
AUTO OPERATION DOES NOT OPERATE
BUT MANUAL OPERATES NORMALLY . .
DRIVER SIDE . . . . . . . . . . . . . . ..
DRIVER SIDE : Diagnosis Procedure . . . . ...
PASSENGER SIDE . . . . . . . . . . . . .
PASSENGER SIDE : Diagnosis Procedure . . ..
ANTI-PINCH FUNCTION DOES NOT OPER-
ATE NORMALLY . . . . . . . . . . . .
DRIVER SIDE . . . . . . . . . . . . . . ..
DRIVER SIDE : Diagnosis Procedure . . . . ...
PASSENGER SIDE . . . . . . . . . . . . .
PASSENGER SIDE : Diagnosis Procedure . . ..
POWER WINDOW RETAINED POWER OP-
ERATION DOES NOT OPERATE PROPERLY
..
Diagnosis Procedure . . . . . . . . . . . .
DOOR KEY CYLINDER SWITCH DOES NOT
OPERATE POWER WINDOWS . . . . . ...
Diagnosis Procedure . . . . . . . . . . . .
KEYLESS POWER WINDOW DOWN DOES
NOT OPERATE . . . . . . . . . . . .
Diagnosis Procedure . . . . . . . . . . . .
POWER WINDOW LOCK SWITCH DOES
NOT FUNCTION . . . . . . . . . . . ..
Diagnosis Procedure . . . . . . . . . . . .
POWER WINDOW SWITCH ILLUMINATION
DOES NOT ILLUMINATE . . . . . . . ...
Diagnosis Procedure . . . . . . . . . . . .
PRECAUTION . . . . . . . . . . .
PRECAUTIONS . . . . . . . . . . . ...
FOR USA AND CANADA . . . . . . . . . .
FOR USA AND CANADA : Precaution for Proce-
dure without Cowl Top Cover . . . . . . . .
FOR MEXICO . . . . . . . . . . . . . . ...
FOR MEXICO : Precaution for Procedure without
Cowl Top Cover . . . . . . . . . . . . . .
FOR MEXICO : Precaution Necessary for Steer-
ing Wheel Rotation after Battery Disconnect . . .
REMOVAL AND INSTALLATION . . . .
POWER WINDOW MAIN SWITCH . . . . .
Exploded View . . . . . . . . . . . . . ...
PWC-4
< BASIC INSPECTION >
DIAGNOSIS AND REPAIR WORK FLOW
BASIC INSPECTION
DIAGNOSIS AND REPAIR WORK FLOW
Work Flow
INFOID:0000000005513308
DETAILED FLOW
1.
OBTAIN INFORMATION ABOUT SYMPTOM
Interview the customer to obtain the malfunction information (conditions and environment when the malfunc-
tion occurred) as much as possible when the customer brings the vehicle in.
>> GO TO 2.
2.
REPRODUCE THE MALFUNCTION INFORMATION
Check the malfunction on the vehicle that the customer describes.
Inspect the relation of the symptoms and the condition when the symptoms occur.
>> GO TO 3.
3.
IDENTIFY THE MALFUNCTIONING SYSTEM WITH “SYMPTOM DIAGNOSIS”
Use “Symptom diagnosis” from the symptom inspection result in step 2 and then identify where to start per-
forming the diagnosis based on possible causes and symptoms.
>> GO TO 4.
4.
IDENTIFY THE MALFUNCTIONING PARTS WITH “COMPONENT DIAGNOSIS”
Perform the diagnosis with “Component diagnosis” of the applicable system.
>> GO TO 5.
5.
REPAIR OR REPLACE THE MALFUNCTIONING PARTS
Repair or replace the specified malfunctioning parts.
>> GO TO 6.
6.
FINAL CHECK
Check that malfunctions are not reproduced when obtaining the malfunction information from the customer,
referring to the symptom inspection result in step 2.
Are the malfunctions corrected?
YES
>> INSPECTION END
NO
>> GO TO 3.
INSPECTION AND ADJUSTMENT
PWC-5
< BASIC INSPECTION >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
INSPECTION AND ADJUSTMENT
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : De-
scription
INFOID:0000000005513309
When battery negative terminal is disconnected, initialization is necessary.
If any of the following operations are performed, initialization is necessary as well as when battery negative
terminal is disconnected.
• Power supply to the power window control unit is cut off by the removal f battery terminal or the battery fuse
is blown.
• Disconnection and connection of power window control unit harness connector.
• Removal and installation of motor from regulator assembly.
• Operation of regulator assembly as an independent unit.
• Removal and installation of rear power window control unit.
• Removal and installation of door glass.
• Removal and installation of door glass run.
The operations as per the following cannot be performed while initialization is not complete.
• AUTO-UP operation
• Anti-pinch function
• Door key cylinder switch power window function
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Spe-
cial Repair Requirement
INFOID:0000000005513310
INITIALIZATION PROCEDURE
1.
Disconnect battery negative terminal or power window control unit connector. Reconnect it after a minute
or more.
2.
Turn ignition switch ON.
3.
Operate power window switch to fully open door glass. (This operation is unnecessary if door glass is
already fully open.)
4.
Pull and hold power window switch UP (AUTO-UP operation). Even after door glass stops at the fully
closed position, pull the switch for 2 seconds or more.
5.
Initialization procedure is complete.
6.
Inspect anti-pinch function.
CHECK ANTI-PINCH FUNCTION
1.
Fully open door glass.
2.
Place a piece of wood near the fully closed position.
3.
Close door glass completely using AUTO-UP.
• Check that door glass lowers approximately 150 mm (5.9 in) without pinching piece of wood and stops.
• Check that door glass does not rise when operating power window main switch while lowering.
CAUTION:
• Perform initialization when AUTO-UP operation or anti-pinch function does not operate normally.
• Check that AUTO-UP operates before inspection when initialization is performed.
• Never check with hands or other body parts because they may be pinched. Never get pinched.
• It may switch to the fail-safe mode if open/close operation is performed continuously without fully
closing door glass. Perform initialization in the above situation. Refer to
• Finish initialization. Otherwise, the next operation cannot be done.
1.
AUTO-UP operation
2.
Anti-pinch function
3.
Door key cylinder switch power window function
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Description
INFOID:0000000005513311
When the control unit is replaced, initialization is necessary.
If any of the following operations are performed, initialization is necessary as well as when the control unit is
disconnected.
PWC-6
< BASIC INSPECTION >
INSPECTION AND ADJUSTMENT
• Power supply to the power window control unit is cut off by the removal of battery terminal or the battery fuse
is blown.
• Disconnection and connection of power window control unit harness connector.
• Removal and installation of motor from regulator assembly.
• Disconnection and connection of battery negative terminal.
• Removal and installation of rear power window control unit.
• Removal and installation of door glass.
• Removal and installation of door glass run.
The following specified operations cannot be performed while initialization is not complete.
• AUTO-UP operation
• Anti-pinch function
• Door key cylinder switch power window function
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Re-
quirement
INFOID:0000000005513312
INITIALIZATION PROCEDURE
1.
Disconnect battery negative terminal or power window control unit connector. Reconnect it after a minute
or more.
2.
Turn ignition switch ON.
3.
Operate power window switch to fully open door glass. (This operation is unnecessary if door glass is
already fully open.)
4.
Pull and hold power window switch UP (AUTO-UP operation). Even after door glass stops at the fully
closed position, pull the switch for 2 seconds or more.
5.
Initialization procedure is complete.
6.
Inspect anti-pinch function.
CHECK ANTI-PINCH FUNCTION
1.
Fully open door glass.
2.
Place a piece of wood near the fully closed position.
3.
Close door glass completely using AUTO-UP.
• Check that door glass lowers approximately 150 mm (5.9 in) without pinching piece of wood and stops.
• Check that door glass does not rise when operating power window main switch while lowering.
CAUTION:
• Perform initialization when AUTO-UP operation or anti-pinch function does not operate normally.
• Check that AUTO-UP operates before inspection when initialization is performed.
• Never check with hands or other body parts because they may be pinched. Never get pinched.
• It may switch to the fail-safe mode if open/close operation is performed continuously without fully
closing. Perform initialization in the above situation. Refer to
.
• Finish initialization. Otherwise, the next operation cannot be done.
1.
AUTO-UP operation
2.
Anti-pinch function
3.
Door key cylinder switch power window function