Nissan Murano Z51. Manual — part 1058
MWI-90
< ECU DIAGNOSIS INFORMATION >
IPDM E/R (INTELLIGENT POWER DISTRIBUTION MODULE ENGINE ROOM)
NOTE:
This operation status can be confirmed on the IPDM E/R “Data Monitor” that displays “BLOCK” for the item
“WIP PROT” while the wiper is stopped.
STARTER MOTOR PROTECTION FUNCTION
IPDM E/R turns OFF the starter control relay to protect the starter motor when the starter control relay remains
active for 90 seconds.
DTC Index
INFOID:0000000005688791
NOTE:
• The details of time display are as follows.
- CRNT: A malfunction is detected now.
- PAST: A malfunction was detected in the past.
• IGN counter is displayed on FFD (Freeze Frame data).
- The number is 0 when is detected now.
- The number increases like 1
→
2 ··· 38
→
39 after returning to the normal condition whenever IGN OFF
→
ON.
- The number is fixed to 39 until the self-diagnosis results are erased if it is over 39.
×
: Applicable
*
: For models without steering lock unit this DTC is not applied.
Ignition switch
Front wiper switch
Front wiper stop position signal
ON
OFF
The front wiper stop position signal (stop
position) cannot be input for 10 seconds.
ON
The front wiper auto stop signal does not
change for 10 seconds.
CONSULT display
Fail-safe
Refer to
No DTC is detected.
further testing
may be required.
—
—
U1000: CAN COMM CIRCUIT
×
B2098: IGN RELAY ON
×
B2099: IGN RELAY OFF
—
B2108: STRG LCK RELAY ON
*
—
B2109: STRG LCK RELAY OFF
*
—
B210A: STRG LCK STATE SW
*
—
B210B: START CONT RLY ON
—
B210C: START CONT RLY OFF
—
B210D: STARTER RELAY ON
—
B210E: STARTER RELAY OFF
—
B210F: INTRLCK/PNP SW ON
—
B2110: INTRLCK/PNP SW OFF
—
MWI
THE FUEL GAUGE POINTER DOES NOT MOVE
MWI-91
< SYMPTOM DIAGNOSIS >
C
D
E
F
G
H
I
J
K
L
M
B
A
O
P
SYMPTOM DIAGNOSIS
THE FUEL GAUGE POINTER DOES NOT MOVE
Description
INFOID:0000000005524908
Fuel gauge needle will not move from a certain position.
Diagnosis Procedure
INFOID:0000000005524909
1.
CHECK FOR THE COMBINATION METER IN SELF-DIAGNOSIS MODE
Check that the fuel gauge needle moves normally by using self-diagnosis function of the combination meter.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Replace combination meter. Refer to
MWI-103, "Removal and Installation"
2.
CHECK COMBINATION METER OUTPUT SIGNAL
1.
Connect CONSULT-III.
2.
Select the “Data Monitor” for the “METER/M&A” and compare the “FUEL METER” monitor value with the
fuel gauge reading on the combination meter. Refer to
MWI-45, "Component Function Check"
.
Does monitor value match fuel gauge reading?
YES
>> GO TO 3.
NO
>> Replace combination meter.
3.
CHECK FUEL LEVEL SENSOR SIGNAL CIRCUIT
Check the fuel level sensor signal circuit. Refer to
.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair harness or connector.
4.
CHECK FUEL LEVEL SENSOR UNIT
Perform a unit check for the fuel level sensor unit. Refer to
MWI-46, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace fuel level sensor unit. Refer to
FL-6, "Removal and Installation"
.
5.
CHECK FLOAT INTERFERENCE
Check that the float arm interferes with or binds to other components in the fuel tank.
Is the inspection result normal?
YES
>> Replace combination meter.
NO
>> Repair or replace malfunctioning parts.
MWI-92
< SYMPTOM DIAGNOSIS >
THE METER CONTROL SWITCH IS INOPERATIVE
THE METER CONTROL SWITCH IS INOPERATIVE
Description
INFOID:0000000005524910
If any of the following malfunctions is found for the meter control switch operation.
• All switches are inoperative.
• The specified switch cannot be operated.
Diagnosis Procedure
INFOID:0000000005524911
1.
CHECK METER CONTROL SWITCH SIGNAL CIRCUIT
Check the meter control switch signal circuit. Refer to
.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair harness or connector.
2.
CHECK METER CONTROL SWITCH
Perform a unit check for the meter control switch. Refer to
MWI-49, "Component Inspection"
Is the inspection result normal?
YES
>> Replace combination meter.
NG
>> Replace meter control switch.
MWI
THE OIL PRESSURE WARNING LAMP DOES NOT TURN ON
MWI-93
< SYMPTOM DIAGNOSIS >
C
D
E
F
G
H
I
J
K
L
M
B
A
O
P
THE OIL PRESSURE WARNING LAMP DOES NOT TURN ON
Description
INFOID:0000000005525074
The oil pressure warning lamp stays off when the ignition switch is turned ON.
Diagnosis Procedure
INFOID:0000000005525075
1.
CHECK OIL PRESSURE WARNING LAMP
Perform auto active test. Refer to
PCS-10, "Diagnosis Description"
Is oil pressure warning lamp blinking?
YES
>> GO TO 2.
NO
>> GO TO 4.
2.
CHECK OIL PRESSURE SWITCH SIGNAL CIRCUIT
Check the oil pressure switch signal circuit. Refer to
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair harness or connector.
3.
CHECK OIL PRESSURE SWITCH
Perform a unit check for the oil pressure switch. Refer to
MWI-51, "Component Inspection"
.
Is the inspection result normal?
YES
>> Replace IPDM E/R.
NO
>> Replace oil pressure switch.
4.
CHECK COMBINATION METER INPUT SIGNAL
Connect CONSULT-III and perform an input signal check for the combination meter. Refer to
.
Is the inspection result normal?
YES
>> Replace combination meter.
NO
>> Replace IPDM E/R. Refer to
PCS-35, "Removal and Installation"
.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст