Nissan Titan A60. Manual — part 602
INSUFFICIENT HEATING
HAC-91
< SYMPTOM DIAGNOSIS >
[AUTOMATIC AIR CONDITIONER]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
INSUFFICIENT HEATING
Component Function Check
INFOID:0000000006164729
SYMPTOM: Insufficient heating
INSPECTION FLOW
1.
CONFIRM SYMPTOM BY PERFORMING OPERATIONAL CHECK - TEMPERATURE INCREASE
1. Press the AUTO switch.
2. Turn the temperature control dial (driver) clockwise until 32
°C (90°F) is displayed.
3. Check for hot air at discharge air outlets.
Can this symptom be duplicated?
YES
>> GO TO 2.
NO
>> Perform complete system operational check. Refer to
2.
CHECK FOR SERVICE BULLETINS
Check for any service bulletins.
>> GO TO 3.
3.
PERFORM SELF-DIAGNOSIS
Perform self-diagnosis. Refer to
HAC-21, "Front Air Control Self-Diagnosis"
Is the inspection results normal?
YES
>> GO TO 4.
NO
>> Refer to
HAC-21, "Front Air Control Self-Diagnosis Code Chart"
4.
CHECK ENGINE COOLING SYSTEM
1. Check for proper engine coolant level. Refer to
2. Check hoses for leaks or kinks.
3. Check radiator cap. Refer to
.
4. Check for air in cooling system.
>> GO TO 5.
5.
CHECK AIR MIX DOOR OPERATION
Check the operation of the air mix door.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Check the air mix door motor circuit. Refer to
HAC-28, "Air Mix Door Motor (Driver) Component
6.
CHECK AIR DUCTS
Check for disconnected or leaking air ducts.
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> Repair all disconnected or leaking air ducts.
7.
CHECK HEATER HOSE TEMPERATURES
1. Start engine and warm it up to normal operating temperature.
2. Touch both the inlet and outlet heater hoses. The inlet hose should be hot and the outlet hose should be
warm.
Is the inspection result normal?
YES
>> Hot inlet hose and a warm outlet hose: GO TO 8.
NO
>> • Inlet hose cold: GO TO 11.
• Both hoses warm: GO TO 9.
8.
CHECK ENGINE COOLANT SYSTEM
HAC-92
< SYMPTOM DIAGNOSIS >
[AUTOMATIC AIR CONDITIONER]
INSUFFICIENT HEATING
Check engine coolant temperature sensor. Refer to
EC-177, "Component Inspection"
Is the inspection result normal?
YES
>> System OK.
NO
>> Repair or replace as necessary. Retest.
9.
CHECK HEATER HOSES
Check heater hoses for proper installation.
Is the inspection result normal?
YES
>> System OK.
NO
>> 1. Back flush heater core.
2. Drain the water from the system.
3. Refill system with new engine coolant. Refer to
CO-11, "Changing Engine Coolant"
4. GO TO 10 to retest.
10.
CHECK HEATER HOSE TEMPERATURES
1. Start engine and warm it up to normal operating temperature.
2. Touch both the inlet and outlet heater hoses. The inlet hose should be hot and the outlet hose should be
warm.
Is the inspection result normal?
YES
>> System OK.
NO
>> Replace heater core. Refer to
VTL-15, "Removal and Installation"
11.
CHECK WATER VALVE
Check the operation of the water valve. Refer to
HAC-54, "Water Valve Diagnosis Procedure"
Is the inspection result normal?
YES
>> System OK.
NO
>> Replace water valve.
NOISE
HAC-93
< SYMPTOM DIAGNOSIS >
[AUTOMATIC AIR CONDITIONER]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
NOISE
Component Function Check
INFOID:0000000006164730
SYMPTOM: Noise
INSPECTION FLOW
*1
*2
*3
*4
HA-43, "Removal and Installation for
Expansion Valve"
*5
HA-33, "Removal and Installation for
Compressor Clutch"
*6
HA-33, "Removal and Installation for
Compressor Clutch"
*7
HA-32, "Removal and Installation for
Compressor"
*8
HA-32, "Removal and Installation for
Compressor"
*9
HA-41, "Removal and Installation for
Condenser"
AWIIA1001GB
HAC-94
< SYMPTOM DIAGNOSIS >
[AUTOMATIC AIR CONDITIONER]
MEMORY FUNCTION DOES NOT OPERATE
MEMORY FUNCTION DOES NOT OPERATE
Memory Function Check
INFOID:0000000006164731
SYMPTOM: Memory function does not operate.
INSPECTION FLOW
1.
CONFIRM SYMPTOM BY PERFORMING OPERATIONAL CHECK - MEMORY FUNCTION
1. Set the temperature to 32
°C (90°F).
2. Rotate the front blower control dial (driver) to turn system OFF.
3. Turn ignition switch OFF.
4. Turn ignition switch ON.
5. Press the AUTO switch.
6. Confirm that the set temperature remains at previous temperature.
7. Press the OFF switch.
Can the symptom be duplicated?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
PERFORM COMPLETE OPERATIONAL CHECK
Perform a complete operational check and check for any symptoms. Refer to
Can a symptom be duplicated?
YES
>> Refer to
HAC-5, "How to Perform Trouble Diagnosis For Quick And Accurate Repair"
.
NO
>> System OK.
3.
CHECK FOR SERVICE BULLETINS
Check for any service bulletins.
>> GO TO 4.
4.
PERFORM SELF-DIAGNOSIS
Perform self-diagnosis to check for any codes. Refer to
HAC-21, "Front Air Control Self-Diagnosis"
.
Are any self-diagnosis codes present?
YES
>> Refer to
HAC-21, "Front Air Control Self-Diagnosis Code Chart"
NO
>> GO TO 5.
5.
CHECK POWER AND GROUND CIRCUIT
Check main power supply and ground circuit. Refer to
HAC-67, "Front Air Control Component Function
.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Repair or replace as necessary.
6.
RECHECK FOR SYMPTOMS
Perform a complete operational check for any symptoms. Refer to
Does another symptom exist?
YES
>> Refer to
HAC-5, "How to Perform Trouble Diagnosis For Quick And Accurate Repair"
.
NO
>> Replace front air control. Refer to
VTL-8, "Removal and Installation"
.