Nissan Titan A60. Manual — part 404
EC-282
< DTC/CIRCUIT DIAGNOSIS >
[VK56DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
DTC Confirmation Procedure
INFOID:0000000006158709
NOTE:
If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-
ing the next step.
1. Turn ignition swich OFF and wait at least 10 seconds.
2. Turn ignition swich ON.
3. Turn ignition swich OFF and wait at least 10 seconds.
TESTING CONDITION:
Always perform test at a temperature of 5
°C (41°F) or more.
WITH CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “PURG VOL CN/V P1444” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with
CONSULT-III.
5. Touch “START”.
6. Start engine and let it idle until “TESTING” on CONSULT-III changes to “COMPLETED”. (It will take
approximately 10 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from step 2.
7. Make sure that “OK” is displayed after touching “SELF-DIAG RESULTS”. If “NG” is displayed, refer to
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and let it idle for at least 20 seconds.
4. Select Service $07 with GST.
5. If 1st trip DTC is detected, go to
Diagnosis Procedure
INFOID:0000000006158710
1.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve
harness connector.
3. Turn ignition switch ON.
BBIA0366E
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-283
< DTC/CIRCUIT DIAGNOSIS >
[VK56DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
4. Check voltage between EVAP canister purge volume control
solenoid valve terminal 1 and ground with CONSULT-III or
tester.
OK or NG
OK
>> GO TO 3.
NG
>> GO TO 2.
2.
DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors E2, F32
• Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
• Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair harness or connectors.
3.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT
FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 45 and EVAP canister purge volume control solenoid
valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK
>> GO TO 4.
NG
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.
2. Check connectors for water.
OK or NG
OK
>> GO TO 5.
NG
>> Replace EVAP control system pressure sensor.
5.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
EC-299, "Component Inspection"
OK or NG
OK (With CONSULT-III)>>GO TO 6.
OK (Without CONSULT-III)>>GO TO 7.
NG
>> Replace EVAP control system pressure sensor.
6.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-III
1. Turn ignition switch OFF.
2. Reconnect all harness connectors disconnected.
3. Start engine.
4. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-III. Check that engine speed var-
ies according to the valve opening.
OK or NG
Voltage: Battery voltage
PBIB2245E
Continuity should exist.
Water should not exist.
EC-284
< DTC/CIRCUIT DIAGNOSIS >
[VK56DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
OK
>> GO TO 8.
NG
>> GO TO 7.
7.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-285, "Component Inspection"
OK or NG
OK
>> GO TO 8.
NG
>> Replace EVAP canister purge volume control solenoid valve.
8.
CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EVAP canister vent control valve.
2. Check the rubber tube for clogging.
OK or NG
OK
>> GO TO 9.
NG
>> Clean the rubber tube using an air blower.
9.
CHECK DRAIN FILTER
EC-285, "Component Inspection"
OK or NG
OK
>> GO TO 10.
NG
>> Replace drain filter.
10.
CHECK EVAP CANISTER VENT CONTROL VALVE
EC-291, "Component Inspection"
OK or NG
OK
>> GO TO 11.
NG
>> Replace EVAP canister vent control valve.
11.
CHECK IF EVAP CANISTER SATURATED WITH WATER
1. Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor
attached.
2. Check if water will drain from the EVAP canister.
Yes or No
Yes
>> GO TO 12.
No
>> GO TO 14.
12.
CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
OK or NG
OK
>> GO TO 14.
NG
>> GO TO 13.
13.
DETECT MALFUNCTIONING PART
Check the following.
• EVAP canister for damage
• EVAP hose between EVAP canister and drain filter for clogging or poor connection
BBIA0351E
Short wheel base:
The weight should be less than 2.5 kg (5.5 lb).
Long wheel base:
The weight should be less than 3.2 kg (7.1 lb).
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-285
< DTC/CIRCUIT DIAGNOSIS >
[VK56DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
>> Repair hose or replace EVAP canister.
14.
CHECK INTERMITTENT INCIDENT
GI-36, "How to Check Terminal"
GI-39, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000006158711
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-III
Check air passage continuity of EVAP canister purge volume control
solenoid valve under the following conditions.
Without CONSULT-III
Check air passage continuity of EVAP canister purge volume control
solenoid valve under the following conditions.
DRAIN FILTER
1. Check visually for insect nests in the drain filter air inlet.
2. Check visually for cracks or flaws in the appearance.
3. Check visually for cracks or flaws in the hose.
4. Blow air into port A and check that it flows freely out of port B.
5. Block port B.
6. Blow air into port A and check that there is no leakage.
7. If NG, replace drain filter.
Condition
(PURG VOL CONT/V value)
Air passage continuity
between A and B
100%
Yes
0%
No
PBIB2058E
Condition
Air passage continuity
between A and B
12V direct current supply between
terminals 1 and 2
Yes
No supply
No
PBIB2059E
PBIB3641E