Nissan Titan A60. Manual — part 779
PWC-20
< DTC/CIRCUIT DIAGNOSIS >
POWER SUPPLY AND GROUND CIRCUIT CHECK (CREW CAB)
2. Disconnect BCM and rear power window switch.
3. Check continuity between BCM connector (A) and rear power
window switch connector (B).
4. Check continuity between BCM connector (A) and ground.
Is the inspection result normal?
YES
>> GO TO 5
NO
>> Repair or replace harness.
5.
CHECK REAR POWER WINDOW SWITCH
Check rear power window switch.
PWC-20, "REAR POWER WINDOW SWITCH : Component Inspection"
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-39, "Intermittent Incident"
.
NO
>> Replace rear power window switch. Refer to
PWC-117, "Removal and Installation - Rear Door
.
REAR POWER WINDOW SWITCH : Component Inspection
INFOID:0000000006161040
COMPONENT INSPECTION
1.
CHECK REAR POWER WINDOW SWITCH
Check rear power window switch.
Is the inspection result normal?
YES
>> Rear power window switch is OK.
NO
>> Replace rear power window switch. Refer to
PWC-117, "Removal and Installation - Rear Door
.
BCM connector
Terminal
Rear power window
switch connector
Terminal
Continuity
M20 (A)
68
LH
D203 (B)
1
Yes
RH
D303 (B)
BCM connector
Terminal
Ground
Continuity
M20 (A)
68
No
ALKIA1017ZZ
Terminal
Power window switch condition
Continuity
1
5
DOWN
Yes
3
4
3
4
NEUTRAL
5
2
1
4
UP
5
2
ALKIA0289ZZ
POWER SUPPLY AND GROUND CIRCUIT CHECK (KING CAB)
PWC-21
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
POWER SUPPLY AND GROUND CIRCUIT CHECK (KING CAB)
POWER WINDOW MAIN SWITCH
POWER WINDOW MAIN SWITCH : Description
INFOID:0000000006161041
• BCM supplies power.
• It operates each power window motor via corresponding power window switch and makes window move up/
down when main power window and door lock/unlock switch is operated.
POWER WINDOW MAIN SWITCH : Component Function Check
INFOID:0000000006161042
Main Power Window And Door Lock/Unlock Switch
1.
CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH FUNCTION
Does power window motor operate with main power window and door lock/unlock switch operation?
Is the inspection result normal?
YES
>> Main power window and door lock/unlock switch power supply and ground circuit are OK.
NO
>> Refer to
PWC-21, "POWER WINDOW MAIN SWITCH : Diagnosis Procedure"
POWER WINDOW MAIN SWITCH : Diagnosis Procedure
INFOID:0000000006161043
Regarding Wiring Diagram information, refer to
PWC-81, "Wiring Diagram - King Cab"
1.
CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch ON.
2. Check voltage between main power window and door lock/
unlock switch connector and ground.
Is the measurement value within the specification?
YES
>> GO TO 3
NO
>> GO TO 2
2.
CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect BCM and main power window and door lock/unlock
switch.
3. Check continuity between BCM connector (A) and main power
window and door lock/unlock switch connector (B).
4. Check continuity between BCM connector (A) and ground.
Terminal
Voltage (V)
(Approx.)
(+)
(–)
Main power window and
door lock/unlock switch
connector
Terminal
D15
1
Ground
Battery voltage
10
LIIA2312E
BCM connector
Terminal
Main power window and
door lock/unlock switch
connector
Terminal
Continuity
M20 (A)
68
D15 (B)
10
Yes
69
1
LIIA2363E
PWC-22
< DTC/CIRCUIT DIAGNOSIS >
POWER SUPPLY AND GROUND CIRCUIT CHECK (KING CAB)
Is the inspection result normal?
YES
>> GO TO 4
NO
>> Repair or replace harness.
3.
CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch.
3. Check continuity between main power window and door lock/
unlock switch connector and ground.
Is the inspection result normal?
YES
>> Replace main power window and door lock/unlock
switch. Refer to
PWC-115, "Removal and Installation"
.
NO
>> Repair or replace harness.
4.
CHECK BCM OUTPUT SIGNAL
1. Connect BCM.
2. Turn ignition switch ON.
3. Check voltage between BCM connector and ground.
Is the measurement value within the specification?
YES
>> GO TO 5
NO
>> Replace BCM. Refer to
BCS-53, "Removal and Installation"
5.
CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH
Check main power window and door lock/unlock switch.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-39, "Intermittent Incident"
.
NO
>> Replace main power window and door lock/unlock switch. Refer to
FRONT POWER WINDOW SWITCH
FRONT POWER WINDOW SWITCH : Description
INFOID:0000000006161044
• BCM supplies power.
• Front power window motor RH will be operated if power window and door lock/unlock switch RH is operated.
FRONT POWER WINDOW SWITCH : Component Function Check
INFOID:0000000006161045
Power Window And Door Lock/Unlock Switch RH
1.
CHECK FRONT POWER WINDOW MOTOR RH FUNCTION
Does front power window motor RH operate with power window and door lock/unlock switch RH operation?
BCM connector
Terminal
Ground
Continuity
M20 (A)
68
No
69
Main power window and door lock/
unlock switch connector
Terminal
Ground
Continuity
D15
15
Yes
LIIA0604E
Terminals
Voltage (V)
(Approx.)
(+)
(–)
BCM connector
Terminal
M20
68
Ground
Battery voltage
69
LIIA0917E
POWER SUPPLY AND GROUND CIRCUIT CHECK (KING CAB)
PWC-23
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
Is the inspection result normal?
YES
>> Power window and door lock/unlock switch RH power supply and ground circuit are OK.
NO
>> Refer to
PWC-23, "FRONT POWER WINDOW SWITCH : Diagnosis Procedure"
FRONT POWER WINDOW SWITCH : Diagnosis Procedure
INFOID:0000000006161046
Regarding Wiring Diagram information, refer to
PWC-81, "Wiring Diagram - King Cab"
1.
CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch ON.
2. Check voltage between power window and door lock/unlock
switch RH connector and ground.
Is the measurement value within the specification?
YES
>> GO TO 3
NO
>> GO TO 2
2.
CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect BCM and power window and door lock/unlock switch
RH.
3. Check continuity between BCM connector (A) and power win-
dow and door lock/unlock switch RH connector (B).
4. Check continuity between BCM connector (A) and ground.
Is the inspection result normal?
YES
>> GO TO 4
NO
>> Repair or replace harness.
3.
CHECK GROUND CIRCUIT
Terminal
Voltage (V)
(Approx.)
(+)
(–)
Power window and door lock/
unlock
switch RH connector
Terminal
D105
10
Ground
Battery voltage
ALKIA0301ZZ
BCM connector
Terminal
Power window and
door lock/unlock
switch RH connector
Terminal
Continuity
M20 (A)
69
D105 (B)
10
Yes
BCM connector
Terminal
Ground
Continuity
M20 (A)
69
No
LIIA2364E
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст