Nissan Frontier D22. Manual — part 603
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-1515
[VG33ER]
C
D
E
F
G
H
I
J
K
L
M
A
EC
Diagnostic Procedure
UBS00DXS
1.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIR-
CUIT
1.
Turn ignition switch OFF.
2.
Disconnect EVAP canister purge volume control solenoid valve
harness connector.
3.
Turn ignition switch ON.
4.
Check voltage between EVAP canister purge volume control
solenoid valve terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK
>> GO TO 3.
NG
>> GO TO 2.
2.
DETECT MALFUNCTIONING PART
Check the following.
●
Harness connectors F36, M81
●
Harness connectors M65, E43
●
Harness for open or short between EVAP canister purge volume control solenoid valve and ECM relay
>> Repair harness or connectors.
3.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT
1.
Turn ignition switch OFF.
2.
Disconnect ECM harness connector.
3.
Check harness continuity between ECM terminal 5 and solenoid terminal 2.
Refer to Wiring Diagram.
4.
Also check harness for short to ground and short to power.
OK or NG
OK (With CONSULT-II)>>GO TO 5.
OK (Without CONSULT-II)>>GO TO 6.
NG
>> GO TO 4.
AEC652A
Voltage: Battery voltage
SEF646W
Continuity should exist.
EC-1516
[VG33ER]
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
4.
DETECT MALFUNCTIONING PART
Check the following.
●
Harness connectors E43, M65
●
Harness connectors M81, F36
●
Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
5.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-II
1.
Start engine.
2.
Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with
CONSULT-II. Check that engine speed varies according to the
valve opening.
OK or NG
OK
>> GO TO 7.
NG
>> GO TO 6.
6.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
1.
Check air passage continuity under the following conditions.
Without CONSULT-II
1.
Check air passage continuity under the following conditions.
OK or NG
OK
>> GO TO 7.
NG
>> Replace EVAP canister purge volume control solenoid
valve.
SEF677Y
Condition
PURG VOL CONT/V value
Air passage continuity
between A and B
100%
Yes
0%
No
SEF660U
Condition
Air passage continuity
between A and B
12V direct current supply between
terminals 1 and 2
Yes
No supply
No
SEF661U
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-1517
[VG33ER]
C
D
E
F
G
H
I
J
K
L
M
A
EC
7.
CHECK INTERMITTENT INCIDENT
Refer to
EC-1297, "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT"
>> INSPECTION END.
EC-1518
[VG33ER]
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
DTC P0447 EVAP CANISTER VENT CONTROL VALVE
PFP:14935
Component Description
UBS00DXT
The EVAP canister vent control valve is located on the EVAP canis-
ter and is used to seal the canister vent.
This solenoid valve responds to signals from the ECM. When the
ECM sends an ON signal, the coil in the solenoid valve is energized.
A plunger will then move to seal the canister vent. The ability to seal
the vent is necessary for the on board diagnosis of other evaporative
emission control system components.
This solenoid valve is used only for diagnosis, and usually remains
opened.
When the vent is closed, under normal purge conditions, the evapo-
rative emission control system is depressurized and allows “EVAP
Control System (Small Leak)” diagnosis.
CONSULT-II Reference Value in Data Monitor Mode
UBS00DXU
Specification data are reference values.
On Board Diagnosis Logic
UBS00DXV
DTC Confirmation Procedure
UBS00DXW
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 5 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11V at idle.
WITH CONSULT-II
1.
Turn ignition switch ON.
SEF032W
SEF143S
MONITOR ITEM
CONDITION
SPECIFICATION
VENT CONT/V
●
Ignition switch: ON
OFF
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0447
EVAP canister vent con-
trol valve circuit open
An improper voltage signal is sent to ECM
through EVAP canister vent control valve.
●
Harness or connectors
(The valve circuit is open or shorted.)
●
EVAP canister vent control valve