Nissan Rogue. Manual — part 650
HAZARD SWITCH
EXL-229
< DTC/CIRCUIT DIAGNOSIS >
[LED HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
HAZARD SWITCH
Component Function Check
INFOID:0000000011421504
1.
CHECK HAZARD SWITCH SIGNAL BY CONSULT
CONSULT DATA MONITOR
1. Turn ignition switch ON.
2. Select “HAZARD SW” in “Data Monitor” of “BCM (FLASHER)”.
3. With operating the hazard switch, check the monitor status.
Is the inspection result normal?
YES
>> Hazard switch circuit is normal.
NO
>> Refer to
EXL-229, "Diagnosis Procedure"
.
Diagnosis Procedure
INFOID:0000000011421505
1.
CHECK HAZARD SWITCH SIGNAL INPUT
1. Turn ignition switch OFF.
2. Disconnect hazard switch connector.
3. Check voltage between hazard switch connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> GO TO 2.
2.
CHECK HAZARD SWITCH SIGNAL OPEN CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between hazard switch harness connector and BCM harness connector.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace harness.
3.
CHECK HAZARD SWITCH SIGNAL SHORT CIRCUIT
Check continuity between hazard switch harness connector and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-75, "Removal and Installation"
(with Intelligent Key system) or
135, "Removal and Installation"
(without Intelligent Key system).
NO
>> Repair or replace harness.
Monitor item
Condition
Monitor status
HAZARD SW
Hazard switch
ON
On
OFF
Off
(+)
(
−)
Voltage (Approx.)
Hazard switch
Connector
Terminal
M26
2
Ground
Battery voltage
Hazard switch
BCM
Continuity
Connector
Terminal
Connector
Terminal
M26
2
M18
11
Yes
Hazard switch
Ground
Continuity
Connector
Terminal
M26
2
No
EXL-230
< DTC/CIRCUIT DIAGNOSIS >
[LED HEADLAMP]
HAZARD SWITCH
4.
CHECK HAZARD SWITCH GROUND OPEN CIRCUIT
Check continuity between hazard switch harness connector and ground.
Is the inspection result normal?
YES
>> Replace hazard switch. Refer to
EXL-125, "Removal and Installation"
NO
>> Repair or replace harness.
Hazard switch
Ground
Continuity
Connector
Terminal
M26
3
Yes
TURN SIGNAL LAMP CIRCUIT
EXL-231
< DTC/CIRCUIT DIAGNOSIS >
[LED HEADLAMP]
C
D
E
F
G
H
I
J
K
M
A
B
EXL
N
O
P
TURN SIGNAL LAMP CIRCUIT
Description
INFOID:0000000011421523
The BCM monitors inputs from the combination switch (lighting and turn signal switch) to determine when to
activate the turn signals. The BCM outputs voltage direction to the left and right turn signals during turn signal
operation or both during hazard warning operation. The BCM sends a turn signal indicator request to the com-
bination meter via the CAN communication lines.
The BCM performs the fast flasher operation (fail-safe) if any bulb or harness of the turn signal lamp circuit is
open.
NOTE:
Turn signal lamp blinks at normal speed when using the hazard warning lamp.
Component Function Check
INFOID:0000000011421524
1.
CHECK TURN SIGNAL LAMP
CONSULT
1. Select “FLASHER” in “Active Test” of “BCM (FLASHER)”.
2. While operating the test items, check that the turn signal lamp blinks.
Is the inspection result normal?
YES
>> Turn signal lamp circuit is normal.
NO
>> Refer to
EXL-231, "Diagnosis Procedure"
.
Diagnosis Procedure
INFOID:0000000011421525
Regarding Wiring Diagram information, refer to
.
1.
CHECK TURN SIGNAL LAMP BULB
Check the applicable lamp bulb to be sure the proper bulb standard is in use and the bulb is not open.
Is the bulb OK?
YES
>> GO TO 2.
NO
>> Replace the bulb.
2.
CHECK TURN SIGNAL LAMP OUTPUT VOLTAGE
1. Turn the ignition switch OFF.
2. Disconnect the front combination lamp harness connector, door mirror harness connector or the side turn
signal harness connector or the rear combination lamp harness connector in question.
3. Turn the ignition switch ON.
4. Operate the turn signal switch.
5. While the turn signal is operating, check the voltage between the front combination lamp harness connec-
tor and ground.
LH
: Turn signal lamps (LH) ON
RH
: Turn signal lamps (RH) ON
Off
: Turn signal lamps OFF
(+)
(
−)
Voltage
(Approx.)
Connector
Terminal
EXL-232
< DTC/CIRCUIT DIAGNOSIS >
[LED HEADLAMP]
TURN SIGNAL LAMP CIRCUIT
6. While the turn signal is operating, check the voltage between the door mirror harness connector and
ground.
7. While the turn signal is operating, check the voltage between the rear combination lamp harness connec-
tor and ground.
Are the inspection results normal?
YES
>> GO TO 5.
NO
>> GO TO 3.
3.
CHECK TURN SIGNAL LAMP CIRCUIT FOR OPEN
1. Turn the ignition switch OFF.
2. Disconnect BCM harness connector E29, M18 or B23.
3. Check continuity between the BCM harness connector E29 and the front combination lamp harness con-
nector.
4. Check continuity between the BCM harness connector B23 and the door mirror harness connector.
LH
E105
1
Ground
RH
E103
(+)
(
−)
Voltage
(Approx.)
Connector
Terminal
LH
D14
13
Ground
RH
D107
(+)
(
−)
Voltage
(Approx.)
Connector
Terminal
LH
B90
3
Ground
RH
B102
PKID0926E
PKID0926E
PKID0926E
BCM
Front combination lamp
Continuity
Connector
Terminal
Connector
Terminal
LH
E29
135
E105
1
Yes
RH
136
E103
BCM
Door mirror
Continuity
Connector
Terminal
Connector
Terminal
LH
M18
2
D14
13
Yes
RH
3
D107
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.