Nissan Rogue. Manual — part 336
DLK-186
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
HAZARD FUNCTION
HAZARD FUNCTION
Component Function Check
INFOID:0000000011278912
1.
CHECK FUNCTION
1. Select “INTELLIGENT KEY” of “BCM” using CONSULT.
2. Select “FLASHER” in “Active Test”.
3. Touch “LH” or “RH” to check that it works normally.
Is the inspection result normal?
YES
>> Hazard warning lamp circuit is OK.
NO
>> Refer to
DLK-186, "Diagnosis Procedure"
.
Diagnosis Procedure
INFOID:0000000011278913
1.
CHECK HAZARD SWITCH CIRCUIT
DLK-186, "Component Function Check"
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace the malfunctioning parts.
2.
CHECK INTERMITTENT INCIDENT
GI-44, "Intermittent Incident"
>> Inspection End.
2015 Rogue NAM
AUTOMATIC BACK DOOR CLOSE SWITCH
DLK-187
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
AUTOMATIC BACK DOOR CLOSE SWITCH
Component Function Check
INFOID:0000000011278914
1.
CHECK FUNCTION
1. Select “AUTO BACK DOOR” using CONSULT.
2. Select “BK DOOR CL SW” in “Data Monitor”.
3. Check that the function operates normally according to the following conditions:
Is the inspection result normal?
YES
>> Automatic back door close switch is OK.
NO
>> Refer to
DLK-187, "Diagnosis Procedure"
Diagnosis Procedure
INFOID:0000000011278915
Regarding Wiring Diagram information, refer to
.
1.
CHECK AUTOMATIC BACK DOOR CLOSE SWITCH INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect automatic back door close switch connector.
3. Check voltage between automatic back door close switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK AUTOMATIC BACK DOOR CLOSE SWITCH CIRCUIT
1. Disconnect automatic back door control module connector.
2. Check continuity between automatic back door control module harness connector and automatic back
door close switch harness connector.
3. Check continuity between automatic back door control module harness connector and ground.
Is the inspection result normal?
YES
>> Replace automatic back door control module. Refer to
DLK-283, "Removal and Installation"
.
NO
>> Repair or replace harness.
3.
CHECK AUTOMATIC BACK DOOR CLOSE SWITCH GROUND CIRCUIT
Monitor item
Condition
Status
BK DOOR CL SW
Automatic back door close switch
Pressed
ON
Released
OFF
(+)
(–)
Voltage
(Approx.)
Automatic back door close switch
Connector
Terminal
D513
1
Ground
Battery voltage
Automatic back door control module
Automatic back door close switch
Continuity
Connector
Terminal
Connector
Terminal
B55
23
D513
1
Yes
Automatic back door control module
Ground
Continuity
Connector
Terminal
B55
23
No
2015 Rogue NAM
DLK-188
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
AUTOMATIC BACK DOOR CLOSE SWITCH
Check continuity between automatic back door close switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK AUTOMATIC BACK DOOR CLOSE SWITCH
DLK-188, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace automatic back door close switch. Refer to
DLK-286, "Removal and Installation"
.
5.
CHECK INTERMITTENT INCIDENT
GI-44, "Intermittent Incident"
>> Inspection End.
Component Inspection
INFOID:0000000011278916
1.
CHECK AUTOMATIC BACK DOOR CLOSE SWITCH
1. Turn ignition switch OFF.
2. Disconnect automatic back door close switch connector.
3. Check continuity between automatic back door close switch terminals.
Is the inspection result normal?
YES
>> Inspection End.
NO
>> Replace automatic back door close switch. Refer to
DLK-286, "Removal and Installation"
.
Automatic back door close switch
Ground
Continuity
Connector
Terminal
D513
2
Yes
Automatic back door close switch
Condition
Continuity
Terminal
1
2
Automatic back door
close switch
Pressed
Yes
Released
No
2015 Rogue NAM
AUTOMATIC BACK DOOR MAIN SWITCH
DLK-189
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
AUTOMATIC BACK DOOR MAIN SWITCH
Component Function Check
INFOID:0000000011278917
1.
CHECK FUNCTION
1. Select “AUTO BACK DOOR” using CONSULT.
2. Select “MAIN SW” in “Data Monitor”.
3. Check that the function operates normally according to the following conditions:
Is the inspection result normal?
YES
>> Automatic back door main switch is OK.
NO
>> Refer to
DLK-189, "Diagnosis Procedure"
Diagnosis Procedure
INFOID:0000000011278918
Regarding Wiring Diagram information, refer to
.
1.
CHECK AUTOMATIC BACK DOOR MAIN SWITCH INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect automatic back door main switch connector.
3. Check voltage between automatic back door main switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK AUTOMATIC BACK DOOR MAIN SWITCH CIRCUIT
1. Disconnect automatic back door control module connector.
2. Check continuity between automatic back door control module harness connector and automatic back
door main switch harness connector.
3. Check continuity between automatic back door control module connector and ground.
Is the inspection result normal?
YES
>> Replace automatic back door control module. Refer to
DLK-283, "Removal and Installation"
.
NO
>> Repair or replace harness.
3.
CHECK AUTOMATIC BACK DOOR MAIN SWITCH GROUND CIRCUIT
Monitor item
Condition
Status
MAIN SW
Automatic back door main switch
ON
ON
OFF
OFF
(+)
(–)
Voltage
(Approx.)
Automatic back door main switch
Connector
Terminal
M178
1
Ground
Battery voltage
Automatic back door control module
Automatic back door main switch
Continuity
Connector
Terminal
Connector
Terminal
B55
10
M178
1
Yes
Automatic back door control module
Ground
Continuity
Connector
Terminal
B55
10
No
2015 Rogue NAM