Nissan Qashqai J11. Manual — part 1250
BACK DOOR OPENER SWITCH
DLK-269
< DTC/CIRCUIT DIAGNOSIS >
[TYPE 2]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK BACK DOOR OPENER SWITCH
DLK-269, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace back door opener switch assembly.
5.
CHECK INTERMITTENT INCIDENT
GI-44, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000010487286
1.
CHECK BACK DOOR OPENER SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect back door opener switch assembly connector.
3.
Check continuity between back door opener switch assembly terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace back door opener switch assembly.
Back door opener switch assembly
Ground
Continuity
Connector
Terminal
D94
4
Existed
Back door opener switch assembly
Condition
Continuity
Terminal
1
4
Back door opener
switch
Pressed
Existed
Released
Not existed
DLK-270
< DTC/CIRCUIT DIAGNOSIS >
[TYPE 2]
BACK DOOR REQUEST SWITCH
BACK DOOR REQUEST SWITCH
Component Function Check
INFOID:0000000010487287
1.
CHECK FUNCTION
1.
Select “INTELLIGENT KEY” of “BCM” using CONSULT.
2.
Select “REQ SW-BD/TR” in “DATA MONITOR” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Back door request switch is OK.
NO
>> Refer to
DLK-270, "Diagnosis Procedure"
.
Diagnosis Procedure
INFOID:0000000010487288
1.
CHECK BACK DOOR REQUEST SWITCH INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect back door opener switch assembly connector.
3.
Check voltage between back door opener switch assembly harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK BACK DOOR REQUEST SWITCH CIRCUIT
1.
Disconnect BCM connector.
2.
Check continuity between BCM harness connector and back door opener switch assembly harness con-
nector.
3.
Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-135, "Removal and Installation"
.
NO
>> Repair harness or connector.
3.
CHECK BACK DOOR REQUEST SWITCH GROUND CIRCUIT
Check continuity between back door opener switch assembly harness connector and ground.
Monitor item
Condition
Status
REQ SW-BD/TR
Back door request switch
Pressed
On
Released
Off
(+)
(–)
Voltage
Back door opener switch assembly
Connector
Terminal
D94
2
Ground
9 - 16 V
BCM
Back door opener switch assembly
Continuity
Connector
Terminal
Connector
Terminal
B4
6
D94
2
Existed
BCM
Ground
Continuity
Connector
Terminal
B4
6
Not existed
BACK DOOR REQUEST SWITCH
DLK-271
< DTC/CIRCUIT DIAGNOSIS >
[TYPE 2]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK BACK DOOR REQUEST SWITCH
DLK-271, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace back door opener switch assembly.
5.
CHECK INTERMITTENT INCIDENT
GI-44, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000010487289
1.
CHECK BACK DOOR REQUEST SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect back door opener switch assembly connector.
3.
Check continuity between back door opener switch assembly terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace back door opener switch assembly.
Back door opener switch assembly
Ground
Continuity
Connector
Terminal
D94
3
Existed
Back door opener switch assembly
Condition
Continuity
Terminal
2
3
Back door request switch
Pressed
Existed
Released
Not existed
DLK-272
< DTC/CIRCUIT DIAGNOSIS >
[TYPE 2]
COMBINATION METER BUZZER
COMBINATION METER BUZZER
Component Function Check
INFOID:0000000010487290
1.
CHECK FUNCTION
1.
Select “INTELLIGENT KEY” of “BCM” using CONSULT.
2.
Select “INSIDE BUZZER” in “ACTIVE TEST” mode.
3.
Touch “Buzzer 1”, “Buzzer 2” or “Buzzer 3” to check that it works normally.
Is the inspection result normal?
Yes
>> Buzzer (combination meter) is OK.
No
>> Refer to
DLK-272, "Diagnosis Procedure"
.
Diagnosis Procedure
INFOID:0000000010487291
1.
CHECK METER BUZZER CIRCUIT
WCS-44, "Component Function Check"
.
Is the inspection result normal?
Yes
>> GO TO 2.
No
>> Repair or replace the malfunctioning parts.
2.
CHECK INTERMITTENT INCIDENT
GI-44, "Intermittent Incident"
>> INSPECTION END
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.