Nissan Qashqai J11. Manual — part 582
EX-8
< PRECAUTION >
[MR20DD]
PRECAUTIONS
PRECAUTION
PRECAUTIONS
Removal and Installation
INFOID:0000000010665049
CAUTION:
• Be sure to use genuine exhaust system parts or equivalents which are specially designed for heat
resistance, corrosion resistance, and shape.
• Perform the operation with the exhaust system fully cooled down because the system will be hot
just after engine stops.
• Be careful not to cut your hand on the heat insulator edge.
• Never use silicon-containing products (e.g. oil) to prevent malfunctions such as the interference with
the conduction of electricity and the occurrence of noise in the radio.
• Prevent rust preventives from adhering to the sensor body.
Precautions for Removing Battery Terminal
INFOID:0000000010665050
• When removing the 12V battery terminal, turn OFF the ignition
switch and wait at least 30 seconds.
NOTE:
ECU may be active for several tens of seconds after the ignition
switch is turned OFF. If the battery terminal is removed before ECU
stops, then a DTC detection error or ECU data corruption may
occur.
• For vehicles with the 2-batteries, be sure to connect the main bat-
tery and the sub battery before turning ON the ignition switch.
NOTE:
If the ignition switch is turned ON with any one of the terminals of
main battery and sub battery disconnected, then DTC may be
detected.
• After installing the 12V battery, always check "Self Diagnosis Result" of all ECUs and erase DTC.
NOTE:
The removal of 12V battery may cause a DTC detection error.
SEF289H
PREPARATION
EX-9
< PREPARATION >
[MR20DD]
C
D
E
F
G
H
I
J
K
L
M
A
EX
N
P
O
PREPARATION
PREPARATION
Special Service Tools
INFOID:0000000010665051
Commercial Service Tools
INFOID:0000000010665052
Tool number
Tool name
Description
KV10114400
Heated oxygen sensor wrench
Loosening or tightening heated oxygen sen-
sor 2
a: For 22 mm (0.87 in) width hexagon nut
S-NT636
Tool name
Description
Power tool
Loosening nuts and bolts
Heated oxygen sensor thread cleaner
Reconditioning the exhaust system threads
before installing a new heated oxygen sensor
(Use with anti-seize lubricant shown below.)
A: J-43897-18 [18 mm (0.71 in) dia.] for zir-
conia heated oxygen sensor
B: J-43897-12 [12 mm (0.47 in) dia.] for tita-
nia heated oxygen sensor
C: Mating surface shave cylinder
D: Flutes
Anti-seize lubricant (Permatex 133AR
or equivalent meeting MIL specifica-
tion MIL-A-907)
Lubricating heated oxygen sensor thread
cleaner when reconditioning exhaust system
threads
PBIC0190E
JPBIA0238ZZ
AEM489
EX-10
< PERIODIC MAINTENANCE >
[MR20DD]
EXHAUST SYSTEM
PERIODIC MAINTENANCE
EXHAUST SYSTEM
Inspection
INFOID:0000000010665053
Check exhaust pipes, muffler, and mounting for improper attach-
ment, leakage, cracks, damage or deterioration.
• If anything is found, repair or replace damaged parts.
SMA211A
EXHAUST SYSTEM
EX-11
< REMOVAL AND INSTALLATION >
[MR20DD]
C
D
E
F
G
H
I
J
K
L
M
A
EX
N
P
O
REMOVAL AND INSTALLATION
EXHAUST SYSTEM
Exploded View
INFOID:0000000010665054
Removal and Installation
INFOID:0000000010665055
REMOVAL
• Disconnect each joint and mounting.
• Remove heated oxygen sensor 2 with following procedure.
Gasket
Exhaust front tube
Heat insulator
Heat insulator (If equipped)
Heated oxygen sensor 2
Mounting rubber
Gasket
Mounting rubber
Main muffler
Mounting rubber
Mounting rubber
To exhaust manifold
: Always replace after every disassembly.
: N·m (kg-m, in-lb)
: N·m (kg-m, ft-lb)
E1BIA1179GB