Nissan Qashqai J11. Manual — part 1084
HA-162
< BASIC INSPECTION >
[TYPE 4]
REFRIGERANT
2.
Operate recovery/recycling/recharging equipment, and evacuate air from A/C system for 25 minutes or
more.
CAUTION:
Evacuate air for 15 minutes or more if the parts are replaced.
3.
Check the airtightness of A/C system for 25 minutes or more. If pressure raises more than the specified
level, charge A/C system with approximately 200 g refrigerant and check that there is no refrigerant leak-
age. Refer to
.
CAUTION:
Check the airtightness for 15 minutes or more if the parts are replaced.
4.
If parts other than compressor are replaced, fill compressor lubricant according to parts that are replaced.
5.
Charge the specified amount of refrigerant to A/C system.
6.
Check that A/C system operates normally.
7.
Disconnect recovery/recycling/recharging equipment. (Collect the refrigerant from the high-pressure hose
and low-pressure hose of recovery/recycling/recharging equipment.)
8.
Install A/C service valve cap.
9.
Refrigerant charge is complete.
LUBRICANT
HA-163
< BASIC INSPECTION >
[TYPE 4]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
LUBRICANT
Description
INFOID:0000000010704914
MAINTENANCE OF LUBRICANT LEVEL
The compressor lubricant is circulating in the system together with the refrigerant. It is necessary to fill com-
pressor with lubricant when replacing A/C system parts or when a large amount of refrigerant leakage is
detected. It is important to always maintain lubricant level within the specified level. Or otherwise, the following
conditions may occur.
• Insufficient lubricant amount: Stuck compressor
• Excessive lubricant amount: Insufficient cooling (caused by insufficient heat exchange)
Inspection
INFOID:0000000010704915
If a compressor is malfunctioning (internal noise, insufficient cooling), check the compressor oil.
1.
COMPRESSOR OIL JUDGMENT
1.
Remove the compressor. Refer to
HA-171, "Removal and Installation"
2.
Sample a compressor oil and judge on the figure.
Judgement result 1>>Replace compressor only.
Judgement result 2>>Replace compressor and condenser & liquid tank assembly.
Perform Lubricant Return Operation
INFOID:0000000010704916
CAUTION:
If a large amount of refrigerant or lubricant leakage is detected, never perform lubricant return opera-
tion.
1.
Start the engine and set to the following conditions.
• Engine speed: Idling to 1,200 rpm
• A/C switch: ON
• Fan (blower) speed: Maximum speed set
• Intake door position: Recirculation
• Temperature setting: Full cold
2.
Perform lubricant return operation for approximately 10 minutes.
3.
Stop the engine.
4.
Lubricant return operation is complete.
Lubricant Adjusting Procedure for Components Replacement Except Compressor
INFOID:0000000010704917
Fill with lubricant for the amount that is calculated according to the following conditions.
Example: Lubricant amount to be added when replacing evaporator and condenser & liquid tank assembly
[m (Imp fl oz)] = 45 (1.6) + 15 (0.5) +
α
Name
: ND-OIL8
JSIIA0927GB
HA-164
< BASIC INSPECTION >
[TYPE 4]
LUBRICANT
Lubricant Adjusting Procedure for Compressor Replacement
INFOID:0000000010704918
1.
Drain lubricant from removed compressor and measure lubricant amount.
• Remove drain bolt (A), and then drain lubricant from drain
port.
• Measure total amount of lubricant that is drained from
removed compressor.
2.
Drain lubricant from a new compressor that is calculated accord-
ing to the following conditions.
CAUTION:
If lubricant amount that is drained from removed compressor is less than 60 m (2.1 Imp fl oz),
perform calculation by setting “D” as 40 m (1.4 Imp fl oz).
Example: Lubricant amount to be drained from a new compressor when replacing compressor and con-
denser & liquid tank assembly [m (Imp fl oz)] [D = 60 (2.1),
α
= 5 (0.2)]
90 (3.2)
−
[60 (2.1) + 20 (0.7) + 30 (1.1) + 5 (0.2)] =
−
25 (
−
0.9)
3.
Tighten drain bolt to the specified torque
Conditions
Lubricant amount to be added to A/C system
m
(Imp fl oz)
Replace evaporator
35 (1.2)
Replace condenser & liquid tank assembly
20 (0.7)
Refrigerant leakage is detected
Large amount leakage
30 (1.1)
Small amount leakage
—
Lubricant amount that is recycled together with refrigerant during recycle operation
α
JMIIA3527ZZ
Amount to be drained (A) [m (Imp fl oz)] = F
−
(D +
S + R +
α
)
F
: Lubricant amount that a new compressor con-
tains [90 (3.2)]
D
: Lubricant amount that is drained from re-
moved compressor
S
: Lubricant amount that remains inside of re-
moved compressor [20 (0.7)]
R
: Lubricant amount to be added according to
components that are removed except compres-
sor
α
: Lubricant amount that is recycled together
with refrigerant during recycle operation
Conditions
Lubricant amount to be added to A/C system
m
(Imp fl oz)
Replace evaporator
45 (1.6)
Replace condenser & liquid tank
30 (1.1)
JPIIA1455GB
LUBRICANT
HA-165
< BASIC INSPECTION >
[TYPE 4]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
4.
Install compressor and check the operation.
Specified torque
: 30 N·m (3.1 kg-m, 22 ft-lb)