Nissan Qashqai J11. Manual — part 1071
HA-110
< BASIC INSPECTION >
[TYPE 3]
REFRIGERANT
REFRIGERANT
Description
INFOID:0000000010704938
CONNECTION OF SERVICE TOOLS AND EQUIPMENT
Leak Test
INFOID:0000000010704939
CHECK REFRIGERANT LEAKAGE USING FLUORESCENT LEAK DETECTION DYE
1.
Install a fender cover (1).
2.
Wear UV safety goggles (2) provided with refrigerant dye leak detection kit.
3.
Connect power cable (4) of UV lamp (6) to positive and negative terminals of the battery (3).
4.
Press UV lamp switch (5) and check A/C system for refrigerant leakage. (Where refrigerant leakage
occurs, fluorescent leak detection dye appears in green color.)
WARNING:
1.
Shut-off valve
2.
A/C service valve
3.
Recovery/recycling/recharging
equipment
4.
Vacuum pump
5.
Manifold gauge set
6.
Refrigerant container (HFC-134a)
7.
Weight scale
A.
Preferred (best) method
B.
Alternative method
C.
For charging
JSIIA0258ZZ
RJIA3815J
REFRIGERANT
HA-111
< BASIC INSPECTION >
[TYPE 3]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
Never look directly into UV lamp light source.
NOTE:
• For continuous operating time of UV lamp, follow the manufacturer operating instructions.
• Illuminate piping joints from different angles using UV lamp and check that there is no leakage.
• Use a mirror in area that is difficult to see to check refrigerant leakage.
• Refrigerant leakage from evaporator can be detected by soaking cotton swab or a similar material with
drain hose water and illuminating it using UV lamp.
• Dust, dirt, and packing materials adhesive used for condenser, evaporator, and other locations may flu-
oresce. Be careful not to misidentify leakage.
5.
Repair or replace parts where refrigerant leakage occurs and wipe off fluorescent leak detection dye.
NOTE:
Completely wipe off fluorescent leak detection dye from gaps between parts, screw threads, and others
using a cotton swab or similar materials.
6.
Use a UV lamp to check that no fluorescent leak detection dye remains after finishing work.
WARNING:
Never look directly into UV lamp light source.
NOTE:
• For continuous operating time of UV lamp, follow the manufacturer operating instructions.
• Dust, dirt, and packing materials adhesive used for condenser, evaporator, and other locations may flu-
oresce. Be careful not to misidentify leakage.
CHECK REFRIGERANT LEAKAGE USING ELECTRICAL LEAK DETECTOR
WARNING:
Never check refrigerant leakage while the engine is running.
CAUTION:
Be careful of the following items so that inaccurate checks or misidentifications are avoided.
• Never allow refrigerant vapor, shop chemical vapors, cigarette smoke, or others around the vehicle.
• Always check refrigerant leakage in a low air flow environment so that refrigerant may not disperse
when leakage occurs.
1.
Stop the engine.
2.
Connect recovery/recycling/recharging equipment or manifold gauge set to A/C service valve.
3.
Check that A/C refrigerant pressure is 345 kPa (3.45 bar, 3.52 kg/cm
2
, 50 psi) or more when temperature
is 16
°
C (61
°
F) or more. When pressure is lower than the specified value, recycle refrigerant completely
and fill refrigerant to the specified level.
NOTE:
Leakages may not be detected if A/C refrigerant pressure is 345 kPa (3.45 bar, 3.52 kg/cm
2
, 50 psi) or
less when temperature is less than 16
°
C (61
°
F).
4.
Clean area where refrigerant leakage check is performed, and check refrigerant leakage along all sur-
faces of pipe connections and A/C system components using electrical leak detector probe.
CAUTION:
• Continue checking when a leakage is found. Always continue and complete checking along all
pipe connections and A/C system components for additional leakage.
• When a leakage is detected, clean leakage area using compressed air and check again.
• When checking leakage of cooling unit inside, always clean inside of drain hose so that the
probe surface may not be exposed to water or dirt.
NOTE:
• Always check leakage starting from high-pressure side and continue to low-pressure side.
• When checking leakage of cooling unit inside, operate blower fan motor for 15 minutes or more at the
maximum fan speed while the engine is stopped, and then insert electrical leak detector probe into drain
hose and hold for 10 minutes or more.
• When disconnecting shut-off valve that is connected to A/C service valve, always evacuate remaining
refrigerant so that misidentification can be avoided.
5.
Repair or replace parts where refrigerant leakage is detected. (Leakage is detected but leakage area is
unknown. GO TO 6.)
6.
Start the engine and set A/C control in the following conditions.
• A/C switch ON
• Air flow: VENT (ventilation)
• Intake door position: Recirculation
HA-112
< BASIC INSPECTION >
[TYPE 3]
REFRIGERANT
• Temperature setting: Full cold
• Fan (blower) speed: Maximum speed set
7.
Run the engine at approximately 1,500 rpm for 2 minutes or more.
8.
Stop the engine. Check again for refrigerant leakage. GO TO 4.
WARNING:
Be careful not to get burned when the engine is hot.
NOTE:
• Start refrigerant leakage check immediately after the engine is
stopped.
• When refrigerant circulation is stopped, pressure on the low-
pressure side rises gradually, and after this, pressure on the
high-pressure side falls gradually.
• The higher the pressure is, the easier it is to find the refriger-
ant leakage.
Recycle Refrigerant
INFOID:0000000010704940
WARNING:
• Always use HFC-134a for A/C refrigerant. If CFC-12 is accidentally charged, compressor is damaged
due to insufficient lubrication.
• Always observe and follow precautions described on refrigerant container. Incorrect handling may
result in an explosion of refrigerant container, frostbite, or the loss of eyesight.
• Never breathe A/C refrigerant and lubricant vapor or mist. Exposure may irritate eyes, nose, or
throat.
• Never allow HFC-134a to be exposed to an open flame or others because it generates poisonous gas
when in contact with high temperature objects. Keep workshop well ventilated.
1.
Perform lubricant return operation. Refer to
HA-114, "Perform Lubricant Return Operation"
. (If refrigerant
or lubricant leakage is detected in a large amount, omit this step, and then GO TO 2.)
CAUTION:
Never perform lubricant return operation if a large amount of refrigerant or lubricant leakage is
detected.
2.
Check gauge pressure readings of recovery/recycling/recharging equipment. When remaining pressure
exists, recycle refrigerant from high-pressure hose and low-pressure hose.
NOTE:
Follow manufacturer instructions for the handling or maintenance of the equipment. Never fill the equip-
ment with non-specified refrigerant.
3.
Remove A/C service valve cap from the vehicle.
4.
Connect recovery/recycling/recharging equipment to A/C service valve.
5.
Operate recovery/recycling/recharging equipment, and recycle refrigerant from the vehicle.
6.
Evacuate air for 10 minutes or more to remove any remaining refrigerant integrated to compressor lubri-
cant, etc.
7.
Refrigerant recycle operation is complete.
Charge Refrigerant
INFOID:0000000010704941
WARNING:
• Always use HFC-134a for A/C refrigerant. If CFC-12 is accidentally charged, compressor is damaged
due to insufficient lubrication.
• Always observe and follow precautions described on refrigerant container. Incorrect handling may
result in an explosion of refrigerant container, frostbite, or the loss of eyesight.
• Never breathe A/C refrigerant and lubricant vapor or mist. Exposure my irritate eyes, nose, or throat.
• Never allow HFC-134a to be exposed to an open flame or others because it generates poisonous gas
when in contact with high temperature objects. Keep workshop well ventilated.
1.
Connect recovery/recycling/recharging equipment to the A/C service valve.
SHA839E
LUBRICANT
HA-113
< BASIC INSPECTION >
[TYPE 3]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
LUBRICANT
Description
INFOID:0000000010704942
MAINTENANCE OF LUBRICANT LEVEL
The compressor lubricant is circulating in the system together with the refrigerant. It is necessary to fill com-
pressor with lubricant when replacing A/C system parts or when a large amount of refrigerant leakage is
detected. It is important to always maintain lubricant level within the specified level. Or otherwise, the following
conditions may occur.
• Insufficient lubricant amount: Stuck compressor
• Excessive lubricant amount: Insufficient cooling (caused by insufficient heat exchange)
Inspection
INFOID:0000000010704943
If a compressor is malfunctioning (internal noise, insufficient cooling), check the compressor oil.
1.
COMPRESSOR OIL JUDGMENT
1.
Remove the compressor. Refer to
HA-121, "Removal and Installation"
2.
Sample a compressor oil and judge on the figure.
Judgement result 1>>Replace compressor only.
Judgement result 2>>Replace compressor and condenser & liquid tank assembly.
Perform Lubricant Return Operation
INFOID:0000000010704944
CAUTION:
If a large amount of refrigerant or lubricant leakage is detected, never perform lubricant return opera-
tion.
1.
Start the engine and set to the following conditions.
• Engine speed: Idling to 1,200 rpm
• A/C switch: ON
• Fan (blower) speed: Maximum speed set
• Intake door position: Recirculation
• Temperature setting: Full cold
2.
Perform lubricant return operation for approximately 10 minutes.
3.
Stop the engine.
4.
Lubricant return operation is complete.
Lubricant Adjusting Procedure for Components Replacement Except Compressor
INFOID:0000000010704945
Fill with lubricant for the amount that is calculated according to the following conditions.
Example: Lubricant amount to be added when replacing evaporator and condenser & liquid tank [m (Imp fl
oz)] = 45 (1.6) + 15 (0.5) +
α
Name
: ND-OIL8
JSIIA0927GB