Nissan Maxima. Manual — part 264
SLIP INDICATOR LAMP
BRC-77
< DTC/CIRCUIT DIAGNOSIS >
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
M
A
B
BRC
N
O
P
SLIP INDICATOR LAMP
Description
INFOID:0000000010049141
×: ON –: OFF
Component Function Check
INFOID:0000000010049142
1.
CHECK SLIP INDICATOR LAMP OPERATION
Check that the lamp illuminates for approximately 2 seconds after the ignition switch is turned ON.
Is the inspection result normal?
YES
>> Inspection End.
NO
>> Go to diagnosis procedure. Refer to
Diagnosis Procedure
INFOID:0000000010049143
1.
CHECK SELF-DIAGNOSIS
Perform ABS actuator and electric unit (control unit) self-diagnosis. Refer to
Is the inspection result normal?
YES
>> GO TO 2
NO
>> Check items displayed by self-diagnosis. Refer to
BRC-21, "CONSULT Function (ABS)"
2.
CHECK COMBINATION METER
Check if the indication and operation of combination meter are normal. Refer to
.
Is the inspection result normal?
YES
>> Replace ABS actuator and electric unit (control unit). Refer to
BRC-106, "Removal and Installa-
.
NO
>> Replace combination meter. Refer to
MWI-122, "Removal and Installation"
Special Repair Requirement
INFOID:0000000010049144
1.
ADJUSTMENT OF STEERING ANGLE SENSOR NEUTRAL POSITION
Always perform the neutral position adjustment for the steering angle sensor, when replacing the ABS actua-
tor and electric unit (control unit). Refer to
BRC-6, "ADJUSTMENT OF STEERING ANGLE SENSOR NEU-
TRAL POSITION : Special Repair Requirement"
>> END
Condition
SLIP indicator lamp
Ignition switch OFF
–
For 2 seconds after turning ON ignition switch
×
2 seconds later after turning ON ignition switch
–
VDC/TCS function is malfunctioning.
×
ABS function is malfunctioning.
×
EBD function is malfunctioning.
×
BRC-78
< ECU DIAGNOSIS INFORMATION >
[VDC/TCS/ABS]
ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT)
ECU DIAGNOSIS INFORMATION
ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT)
Reference Value
INFOID:0000000010049145
VALUES ON THE DIAGNOSIS TOOL
CAUTION:
The display shows the control unit calculation data, so a normal value might be displayed even in the
event the output circuit (harness) is open or short-circuited.
Monitor item
Display content
Data monitor
Condition
Reference value in
normal operation
FR LH SENSOR
Wheel speed
0 [km/h, mph]
Vehicle stopped
Nearly matches the speed meter display
(
± 10% or less)
Vehicle running
(Note 1)
FR RH SENSOR
Wheel speed
0 [km/h, mph]
Vehicle stopped
Nearly matches the speed meter display
(
± 10% or less)
Vehicle running
(Note 1)
RR LH SENSOR
Wheel speed
0 [km/h, mph]
Vehicle stopped
Nearly matches the speed meter display
(
± 10% or less)
Vehicle running
(Note 1)
RR RH SENSOR
Wheel speed
0 [km/h, mph]
Vehicle stopped
Nearly matches the speed meter display
(
± 10% or less)
Vehicle running
(Note 1)
FR LH IN SOL
Operation status of all solenoid valves
Actuator (solenoid valve) is active (“AC-
TIVE TEST” with CONSULT) or actuator
relay is inactive (in fail-safe mode)
On
When the actuator (solenoid valve) is not
active and actuator relay is active (igni-
tion switch ON)
Off
FR LH OUT SOL
Operation status of all solenoid valves
Actuator (solenoid valve) is active (“AC-
TIVE TEST” with CONSULT) or actuator
relay is inactive (in fail-safe mode)
On
When the actuator (solenoid valve) is not
active and actuator relay is active (igni-
tion switch ON)
Off
FR RH IN SOL
Operation status of all solenoid valves
Actuator (solenoid valve) is active (“AC-
TIVE TEST” with CONSULT) or actuator
relay is inactive (in fail-safe mode)
On
When the actuator (solenoid valve) is not
active and actuator relay is active (igni-
tion switch ON)
Off
FR RH OUT SOL
Operation status of all solenoid valves
Actuator (solenoid valve) is active (“AC-
TIVE TEST” with CONSULT) or actuator
relay is inactive (in fail-safe mode)
On
When the actuator (solenoid valve) is not
active and actuator relay is active (igni-
tion switch ON)
Off
RR LH IN SOL
Operation status of all solenoid valves
Actuator (solenoid valve) is active (“AC-
TIVE TEST” with CONSULT) or actuator
relay is inactive (in fail-safe mode)
On
When the actuator (solenoid valve) is not
active and actuator relay is active (igni-
tion switch ON)
Off
ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT)
BRC-79
< ECU DIAGNOSIS INFORMATION >
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
M
A
B
BRC
N
O
P
RR LH OUT SOL
Operation status of all solenoid valves
Actuator (solenoid valve) is active (“AC-
TIVE TEST” with CONSULT) or actuator
relay is inactive (in fail-safe mode)
On
When the actuator (solenoid valve) is not
active and actuator relay is active (igni-
tion switch ON)
Off
RR RH IN SOL
Operation status of all solenoid valves
Actuator (solenoid valve) is active (“AC-
TIVE TEST” with CONSULT) or actuator
relay is inactive (in fail-safe mode)
On
When the actuator (solenoid valve) is not
active and actuator relay is active (igni-
tion switch ON)
Off
RR RH OUT SOL
Operation status of all solenoid valves
Actuator (solenoid valve) is active (“AC-
TIVE TEST” with CONSULT) or actuator
relay is inactive (in fail-safe mode)
On
When the actuator (solenoid valve) is not
active and actuator relay is active (igni-
tion switch ON)
Off
EBD WARN LAMP
EBD warning lamp
(Note 2)
When EBD warning lamp is ON
On
When EBD warning lamp is OFF
Off
STOP LAMP SW
Brake pedal operation
When brake pedal is depressed
On
When brake pedal is not depressed
Off
MOTOR RELAY
Motor and motor relay operation
When the motor relay and motor are op-
erating
On
When the motor relay and motor are not
operating
Off
ACTUATOR RLY
Actuator relay operation
When the actuator relay is operating
On
When the actuator relay is not operating
Off
ABS WARN LAMP
ABS warning lamp
(Note 2)
When ABS warning lamp is ON
On
When ABS warning lamp is OFF
Off
OFF LAMP
VDC OFF indicator lamp
(Note 2)
When VDC OFF indicator lamp is ON
On
When VDC OFF indicator lamp is OFF
Off
SLIP LAMP
SLIP indicator lamp
(Note 2)
When SLIP indicator lamp is ON
On
When SLIP indicator lamp is OFF
Off
BATTERY VOLT
Battery voltage supplied to the ABS actuator
and electric unit (control unit)
Ignition switch ON
10 – 16 V
GEAR
Manual mode gear position determined by
TCM
1st gear
2nd gear
3rd gear
4th gear
5th gear
6th gear
1
2
3
4
5
6
SLCT LVR POSI
CVT shift position
P position
R position
N position
D position
N/P
R
N/P
D
YAW RATE SEN
Yaw rate detected by yaw rate/side G sensor
When vehicle stop
Approx. 0 d/s
When vehicle turning
-75 to 75 d/s
Monitor item
Display content
Data monitor
Condition
Reference value in
normal operation
BRC-80
< ECU DIAGNOSIS INFORMATION >
[VDC/TCS/ABS]
ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT)
ACCEL POS SIG
Throttle actuator opening/closing is dis-
played (linked with accelerator pedal)
Accelerator pedal not depressed (ignition
switch is ON)
0 %
Depress accelerator pedal (ignition
switch is ON)
0 - 100 %
SIDE G-SENSOR
Transverse G detected by side G sensor
Vehicle stopped
Approx. 0 m/s
2
Vehicle turning right
Negative value
(m/s
2
)
Vehicle turning left
Positive value
(m/s
2
)
STR ANGLE SIG
Steering angle detected by steering angle
sensor
Straight-ahead
Approx. 0
°
Steering wheel turned
–720 to 720
°
PRESS SENSOR
Brake fluid pressure detected by pressure
sensor
With ignition switch turned ON and brake
pedal released
Approx. 0 bar
With ignition switch turned ON and brake
pedal depressed
–40 to 300 bar
EBD SIGNAL
EBD operation
EBD is active
On
EBD is inactive
Off
ABS SIGNAL
ABS operation
ABS is active
On
ABS is inactive
Off
TCS SIGNAL
TCS operation
TCS is active
On
TCS is inactive
Off
VDC SIGNAL
VDC operation
VDC is active
On
VDC is inactive
Off
EBD FAIL SIG
EBD fail-safe signal
In EBD fail-safe
On
EBD is normal
Off
ABS FAIL SIG
ABS fail-safe signal
In ABS fail-safe
On
ABS is normal
Off
TCS FAIL SIG
TCS fail-safe signal
In TCS fail-safe
On
TCS is normal
Off
VDC FAIL SIG
VDC fail-safe signal
In VDC fail-safe
On
VDC is normal
Off
CRANKING SIG
Crank operation
Crank is active
On
Crank is inactive
Off
FLUID LEV SW
Brake fluid level switch
When brake fluid level switch ON
On
When brake fluid level switch OFF
Off
PARK BRAKE SW
Parking brake switch
Parking brake switch is active
On
Parking brake switch is inactive
Off
USV[FL-RR]
VDC switch-over valve
When actuator (switch-over valve) is ac-
tive (“ACTIVE TEST” with CONSULT) or
actuator relay is inactive (when in fail-
safe mode)
On
When actuator (switch-over valve) is not
active and actuator relay is active (igni-
tion switch ON)
Off
Monitor item
Display content
Data monitor
Condition
Reference value in
normal operation