Nissan Maxima. Manual — part 991
SUNSHADE SYSTEM DOES NOT OPERATE PROPERLY
RF-137
< SYMPTOM DIAGNOSIS >
[WITH DUAL PANEL SUNROOF]
C
D
E
F
G
H
I
J
L
M
A
B
RF
N
O
P
SUNSHADE SYSTEM DOES NOT OPERATE PROPERLY
Diagnosis Procedure
INFOID:0000000010049006
1.
CHECK SUNSHADE MECHANISM
Check the following.
• Operation malfunction caused by sunshade mechanism deformation, pinched harness or other foreign
materials
• Operation malfunction and interference with other parts by poor installation
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace the malfunctioning parts.
2.
CHECK SUNSHADE MOTOR ASSEMBLY POWER SUPPLY AND GROUND CIRCUIT
Check sunshade motor assembly power supply and ground circuit.
RF-85, "SUNSHADE MOTOR ASSEMBLY : Diagnosis Procedure"
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace the malfunctioning parts.
3.
CHECK COMMUNICATION CIRCUIT
Check communication circuit.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace the harness.
4.
CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES
>> Check intermittent incident. Refer to
GI-41, "Intermittent Incident"
.
NO
>> GO TO 1.
RF-138
< SYMPTOM DIAGNOSIS >
[WITH DUAL PANEL SUNROOF]
AUTO OPERATION DOES NOT OPERATE
AUTO OPERATION DOES NOT OPERATE
Diagnosis Procedure
INFOID:0000000010049007
1.
PERFORM INITIALIZATION PROCEDURE
Initialization procedure is executed and operation is confirmed.
Refer to
RF-76, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Require-
Is the inspection result normal?
YES
>> Sunroof and sunshade system is normal.
NO
>> GO TO 2.
2.
CHECK SUNROOF SWITCH
Check sunroof switch.
.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace the malfunctioning parts.
3.
CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES
>> Check intermittent incident. Refer to
GI-41, "Intermittent Incident"
.
NO
>> GO TO 1.
RETAINED POWER OPERATION DOES NOT OPERATE PROPERLY
RF-139
< SYMPTOM DIAGNOSIS >
[WITH DUAL PANEL SUNROOF]
C
D
E
F
G
H
I
J
L
M
A
B
RF
N
O
P
RETAINED POWER OPERATION DOES NOT OPERATE PROPERLY
Diagnosis Procedure
INFOID:0000000010049008
1.
CHECK FRONT DOOR SWITCH
Check front door switch.
.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace the malfunctioning parts.
2.
CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES
>> Check intermittent incident. Refer to
GI-41, "Intermittent Incident"
.
NO
>> GO TO 1.
RF-140
< SYMPTOM DIAGNOSIS >
[WITH DUAL PANEL SUNROOF]
ANTI-PINCH FUNCTION DOES NOT OPERATE
ANTI-PINCH FUNCTION DOES NOT OPERATE
Diagnosis Procedure
INFOID:0000000010049009
1.
CHECK SUNROOF AND SUNSHADE MECHANISM
Check the following.
• Operation malfunction caused by sunroof and sunshade mechanism deformation, pinched harness or other
foreign materials
• Operation malfunction and interference with other parts by poor installation
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace the malfunctioning parts.
2.
PERFORM INITIALIZATION
Perform initialization procedure.
Refer to
RF-76, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Require-
Is the inspection result normal?
YES
>> Sunroof and sunshade system is normal.
NO
>> GO TO 1.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.