Nissan Maxima. Manual — part 939
POWER WINDOW MAIN SWITCH
PWC-53
< ECU DIAGNOSIS INFORMATION >
[LH&RH FRONT WINDOW ANTI-PINCH]
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
Fail Safe
INFOID:0000000010051255
FAIL-SAFE CONTROL
Switches to fail-safe control when malfunction is detected in encoder signal that detects up/down speed and
direction of door glass. Switches to fail-safe control when error beyond regulation value is detected between
the fully closed position and the actual position of the glass.
9
(Y)
2
Encoder pulse signal 2
Input
When power window mo-
tor operates.
10
(V)
Ground RAP signal
Input
IGN SW ON
Battery voltage
Within 45 seconds after ig-
nition switch is turned to
OFF.
Battery voltage
When front LH or RH door
is opened during retained
power operation.
0
11
(LG)
8
Front door power window mo-
tor LH DOWN signal
Output
When front LH switch in
main power window and
door lock/unlock switch is
operated DOWN.
Battery voltage
13
(G)
2
Encoder pulse signal 1
Input
When power window mo-
tor operates.
14
(O)
Ground Power window serial link
Input/
Output
IGN SW ON or power win-
dow timer operating.
15
(BR)
Ground Encoder power supply
Output
When ignition switch ON or
power window timer oper-
ates.
10
17
(B)
Ground Ground
—
—
0
19
(R)
Ground Battery power supply
Input
—
Battery voltage
Terminal No.
Description
Condition
Voltage [V]
(Approx.)
+
-
Signal name
Input/
Output
JMKIA0070GB
JMKIA0070GB
JPMIA0013GB
Error
Error condition
Pulse sensor malfunction
When only one side of pulse signal is being detected for more than the specified value.
Both pulse sensors mal-
function
When both pulse signals have not been detected for more than the specified value during glass open/
close operation.
PWC-54
< ECU DIAGNOSIS INFORMATION >
[LH&RH FRONT WINDOW ANTI-PINCH]
POWER WINDOW MAIN SWITCH
It changes to condition before initialization and the following functions do not operate when switched to fail-
safe control:
• Auto-up operation
• Anti-pinch function
• Retained power function
Perform initial operation to recover when switched to fail-safe mode. However, it switches back to fail-safe
control when malfunction is found in power window switch or in motor.
Pulse direction malfunction
When the pulse signal that is detected during glass open/close operation detects the opposite condition
of power window motor operating direction.
Glass recognition position
malfunction 1
When it detects the error between glass fully closed position in power window switch memory and actual
fully closed position during glass open/close operation is more than the specified value.
Glass recognition position
malfunction 2
When it detects pulse count more than the value of glass full stroke during glass open/close operation.
Malfunction of not yet up-
dated closed position of
glass
When glass open/close operation is continuously performed without fully closing more than the specified
value (approximately 10 strokes).
Error
Error condition
POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH
PWC-55
< ECU DIAGNOSIS INFORMATION >
[LH&RH FRONT WINDOW ANTI-PINCH]
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH
Reference Value
INFOID:0000000010051256
TERMINAL LAYOUT
PHYSICAL VALUES
POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH
LIIA2454E
Terminal No.
Description
Condition
Voltage [V]
(Approx.)
+
-
Signal name
Input/
Output
3
(W)
Ground
Encoder ground
—
—
0
4
(BR)
Ground
Encoder power supply
Output
When ignition switch ON or
power window timer operates.
10
8
(L)
9
Power window motor
UP signal
Output
When power window motor is
operated UP.
Battery voltage
9
(LG)
8
Power window motor
DOWN signal
Output
When power window motor is
operated DOWN.
Battery voltage
10
(P)
Ground
Battery power supply
Input
—
Battery voltage
11
(B)
Ground
Ground
—
—
0
12
(G)
3
Encoder pulse signal 1
Input
When power window motor op-
erates.
JMKIA0070GB
PWC-56
< ECU DIAGNOSIS INFORMATION >
[LH&RH FRONT WINDOW ANTI-PINCH]
POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH
Fail Safe
INFOID:0000000010051257
FAIL-SAFE CONTROL
Switches to fail-safe control when malfunction is detected in encoder signal that detects up/down speed and
direction of door glass. Switches to fail-safe control when error beyond regulation value is detected between
the fully closed position and the actual position of the glass.
It changes to condition before initialization and the following functions do not operate when switched to fail-
safe control:
• Auto-up operation
• Anti-pinch function
• Retained power function
Perform initial operation to recover when switched to fail-safe mode. However, it switches back to fail-safe
control when malfunction is found in power window switch or in motor.
15
(Y)
3
Encoder pulse signal 2
Input
When power window motor op-
erates.
16
(R)
Ground
Power window serial link
Input/
Output
IGN SW ON or power window
timer operating.
Terminal No.
Description
Condition
Voltage [V]
(Approx.)
+
-
Signal name
Input/
Output
JMKIA0070GB
JPMIA0013GB
Error
Error condition
Pulse sensor malfunction
When only one side of pulse signal is being detected for more than the specified value.
Both pulse sensors mal-
function
When both pulse signals have not been detected for more than the specified value during glass open/
close operation.
Pulse direction malfunction
When the pulse signal that is detected during glass open/close operation detects the opposite condition
of power window motor operating direction.
Glass recognition position
malfunction 1
When it detects the error between glass fully closed position in power window switch memory and actual
fully closed position during glass open/close operation is more than the specified value.
Glass recognition position
malfunction 2
When it detects pulse count more than the value of glass full stroke during glass open/close operation.
Malfunction of not yet up-
dated closed position of
glass
When glass open/close operation is continuously performed without fully closing more than the specified
value (approximately 10 strokes).