Nissan Murano. Manual — part 1116
PWC-2
REAR RH . . . . . . . . . . . . . . . . ..
REAR RH : Description . . . . . . . . . . ..
REAR RH : Component Function Check . . . ....
REAR RH : Diagnosis Procedure . . . . . . ...
REAR RH : Component Inspection . . . . . ....
ENCODER CIRCUIT . . . . . . . . . . ..
DRIVER SIDE . . . . . . . . . . . . . . ....
DRIVER SIDE : Description . . . . . . . . ....
DRIVER SIDE : Component Function Check . . .
DRIVER SIDE : Diagnosis Procedure . . . . ....
PASSENGER SIDE . . . . . . . . . . . . ...
PASSENGER SIDE : Description . . . . . . ...
PASSENGER SIDE : Component Function Check
...
PASSENGER SIDE : Diagnosis Procedure . . ...
POWER WINDOW SERIAL LINK . . . . . .
POWER WINDOW MAIN SWITCH . . . . . . ...
POWER WINDOW MAIN SWITCH : Description ...
POWER WINDOW MAIN SWITCH : Component
Function Check . . . . . . . . . . . . . ...
POWER WINDOW MAIN SWITCH : Diagnosis
Procedure . . . . . . . . . . . . . . . ...
FRONT POWER WINDOW SWITCH (PASSEN-
GER SIDE) . . . . . . . . . . . . . . . ....
FRONT POWER WINDOW SWITCH (PASSEN-
GER SIDE) : Description . . . . . . . . . ....
FRONT POWER WINDOW SWITCH (PASSEN-
GER SIDE) : Component Function Check . . . ..
FRONT POWER WINDOW SWITCH (PASSEN-
GER SIDE) : Diagnosis Procedure . . . . . . .
ECU DIAGNOSIS INFORMATION . . . ..
BCM (BODY CONTROL MODULE) . . . . ..
Reference Value . . . . . . . . . . . . . .
Wiring Diagram - BCM - . . . . . . . . . . .
Fail-safe . . . . . . . . . . . . . . . . ..
DTC Inspection Priority Chart . . . . . . . ..
DTC Index . . . . . . . . . . . . . . . ..
POWER WINDOW MAIN SWITCH . . . . .
Reference Value . . . . . . . . . . . . . .
Wiring Diagram - POWER WINDOW SYSTEM - ...
Fail Safe . . . . . . . . . . . . . . . . .
FRONT POWER WINDOW SWITCH (PAS-
SENGER SIDE) . . . . . . . . . . . . ..
Reference Value . . . . . . . . . . . . . .
Wiring Diagram - POWER WINDOW SYSTEM - ...
Fail Safe . . . . . . . . . . . . . . . .
SYMPTOM DIAGNOSIS . . . . . . .
POWER WINDOWS DO NOT OPERATE
WITH ANY POWER WINDOW SWITCHES .
Diagnosis Procedure . . . . . . . . . . . .
DRIVER SIDE POWER WINDOW DOES NOT
OPERATE . . . . . . . . . . . . . . .
Diagnosis Procedure . . . . . . . . . . . .
FRONT PASSENGER SIDE POWER WIN-
DOW DOES NOT OPERATE . . . . . . ...
WHEN POWER WINDOW MAIN SWITCH IS OP-
ERATED . . . . . . . . . . . . . . . . ..
WHEN POWER WINDOW MAIN SWITCH IS OP-
ERATED : Diagnosis Procedure . . . . . . ...
WHEN FRONT POWER WINDOW SWITCH (PAS-
SENGER SIDE) IS OPERATED . . . . . . . ..
REAR LH SIDE POWER WINDOW ALONE
DOES NOT OPERATE . . . . . . . . . .
WHEN POWER WINDOW MAIN SWITCH IS OP-
ERATED . . . . . . . . . . . . . . . . ..
WHEN POWER WINDOW MAIN SWITCH IS OP-
ERATED : Diagnosis Procedure . . . . . . ...
WHEN REAR POWER WINDOW SWITCH LH IS
OPERATED . . . . . . . . . . . . . . . .
WHEN REAR POWER WINDOW SWITCH LH IS
OPERATED : Diagnosis Procedure . . . . . ..
REAR RH SIDE POWER WINDOW ALONE
DOES NOT OPERATE . . . . . . . . . .
WHEN POWER WINDOW MAIN SWITCH IS OP-
ERATED . . . . . . . . . . . . . . . . ..
WHEN POWER WINDOW MAIN SWITCH IS OP-
ERATED : Diagnosis Procedure . . . . . . ...
WHEN REAR POWER WINDOW SWITCH RH IS
OPERATED . . . . . . . . . . . . . . . .
WHEN REAR POWER WINDOW SWITCH RH IS
OPERATED : Diagnosis Procedure . . . . . ..
PWC-3
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
AUTO OPERATION DOES NOT OPERATE
BUT MANUAL OPERATES NORMALLY . .
DRIVER SIDE . . . . . . . . . . . . . . ..
DRIVER SIDE : Diagnosis Procedure . . . . ...
PASSENGER SIDE . . . . . . . . . . . . .
PASSENGER SIDE : Diagnosis Procedure . . ..
ANTI-PINCH FUNCTION DOES NOT OPER-
ATE NORMALLY . . . . . . . . . . . .
DRIVER SIDE . . . . . . . . . . . . . . ..
DRIVER SIDE : Diagnosis Procedure . . . . ...
PASSENGER SIDE . . . . . . . . . . . . .
PASSENGER SIDE : Diagnosis Procedure . . ..
POWER WINDOW RETAINED POWER OP-
ERATION DOES NOT OPERATE PROPERLY
..
Diagnosis Procedure . . . . . . . . . . . .
DOOR KEY CYLINDER SWITCH DOES NOT
OPERATE POWER WINDOWS . . . . . ...
Diagnosis Procedure . . . . . . . . . . . .
KEYLESS POWER WINDOW DOWN DOES
NOT OPERATE . . . . . . . . . . . .
Diagnosis Procedure . . . . . . . . . . . .
POWER WINDOW LOCK SWITCH DOES
NOT FUNCTION . . . . . . . . . . . ..
Diagnosis Procedure . . . . . . . . . . . .
POWER WINDOW SWITCH ILLUMINATION
DOES NOT ILLUMINATE . . . . . . . ...
Diagnosis Procedure . . . . . . . . . . . .
PRECAUTION . . . . . . . . . . .
PRECAUTIONS . . . . . . . . . . . ...
FOR USA AND CANADA . . . . . . . . . .
FOR USA AND CANADA : Precaution for Proce-
dure without Cowl Top Cover . . . . . . . .
FOR USA AND CANADA : Precautions for Re-
moving of Battery Terminal . . . . . . . . .
FOR MEXICO . . . . . . . . . . . . . . ...
FOR MEXICO : Precaution for Procedure without
Cowl Top Cover . . . . . . . . . . . . . .
FOR MEXICO : Precautions for Removing of Bat-
tery Terminal . . . . . . . . . . . . . . ..
REMOVAL AND INSTALLATION . . . .
POWER WINDOW MAIN SWITCH . . . . .
Exploded View . . . . . . . . . . . . . ...
PWC-4
< BASIC INSPECTION >
DIAGNOSIS AND REPAIR WORK FLOW
BASIC INSPECTION
DIAGNOSIS AND REPAIR WORK FLOW
Work Flow
INFOID:0000000009723114
DETAILED FLOW
1.
OBTAIN INFORMATION ABOUT SYMPTOM
Interview the customer to obtain the malfunction information (conditions and environment when the malfunc-
tion occurred) as much as possible when the customer brings the vehicle in.
>> GO TO 2.
2.
REPRODUCE THE MALFUNCTION INFORMATION
Check the malfunction on the vehicle that the customer describes.
Inspect the relation of the symptoms and the condition when the symptoms occur.
>> GO TO 3.
3.
IDENTIFY THE MALFUNCTIONING SYSTEM WITH “SYMPTOM DIAGNOSIS”
Use “Symptom diagnosis” from the symptom inspection result in step 2 and then identify where to start per-
forming the diagnosis based on possible causes and symptoms.
>> GO TO 4.
4.
IDENTIFY THE MALFUNCTIONING PARTS WITH “COMPONENT DIAGNOSIS”
Perform the diagnosis with “Component diagnosis” of the applicable system.
>> GO TO 5.
5.
REPAIR OR REPLACE THE MALFUNCTIONING PARTS
Repair or replace the specified malfunctioning parts.
>> GO TO 6.
6.
FINAL CHECK
Check that malfunctions are not reproduced when obtaining the malfunction information from the customer,
referring to the symptom inspection result in step 2.
Are the malfunctions corrected?
YES
>> INSPECTION END
NO
>> GO TO 3.
INSPECTION AND ADJUSTMENT
PWC-5
< BASIC INSPECTION >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
INSPECTION AND ADJUSTMENT
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : De-
scription
INFOID:0000000009723115
When battery negative terminal is disconnected, initialization is necessary.
If any of the following operations are performed, initialization is necessary as well as when battery negative
terminal is disconnected.
• Power supply to the power window control unit is cut off by the removal f battery terminal or the battery fuse
is blown.
• Disconnection and connection of power window control unit harness connector.
• Removal and installation of motor from regulator assembly.
• Operation of regulator assembly as an independent unit.
• Removal and installation of rear power window control unit.
• Removal and installation of door glass.
• Removal and installation of door glass run.
The operations as per the following cannot be performed while initialization is not complete.
• AUTO-UP operation
• Anti-pinch function
• Door key cylinder switch power window function
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Spe-
cial Repair Requirement
INFOID:0000000009723116
INITIALIZATION PROCEDURE
1.
Disconnect battery negative terminal or power window control unit connector. Reconnect it after a minute
or more.
2.
Turn ignition switch ON.
3.
Operate power window switch to fully open door glass. (This operation is unnecessary if door glass is
already fully open.)
4.
Pull and hold power window switch UP (AUTO-UP operation). Even after door glass stops at the fully
closed position, pull the switch for 2 seconds or more.
5.
Initialization procedure is complete.
6.
Inspect anti-pinch function.
CHECK ANTI-PINCH FUNCTION
1.
Fully open door glass.
2.
Place a piece of wood near the fully closed position.
3.
Close door glass completely using AUTO-UP.
• Check that door glass lowers approximately 150 mm (5.9 in) without pinching piece of wood and stops.
• Check that door glass does not rise when operating power window main switch while lowering.
CAUTION:
• Perform initialization when AUTO-UP operation or anti-pinch function does not operate normally.
• Check that AUTO-UP operates before inspection when initialization is performed.
• Never check with hands or other body parts because they may be pinched. Never get pinched.
• It may switch to the fail-safe mode if open/close operation is performed continuously without fully
closing door glass. Perform initialization in the above situation. Refer to
• Finish initialization. Otherwise, the next operation cannot be done.
1.
AUTO-UP operation
2.
Anti-pinch function
3.
Door key cylinder switch power window function
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Description
INFOID:0000000009723117
When the control unit is replaced, initialization is necessary.
If any of the following operations are performed, initialization is necessary as well as when the control unit is
disconnected.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.