Nissan Versa Sedan. Manual — part 484
HIGH-PRESSURE PIPE
HA-35
< REMOVAL AND INSTALLATION >
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
HIGH-PRESSURE PIPE
Removal and Installation
INFOID:0000000009269758
CAUTION:
Perform oil return operation before each refrigeration system disassembly. However, if a large amount
of refrigerant or oil is detected, do not perform oil return operation. Refer to
REMOVAL
1. Remove low-pressure flexible hose. Refer to
HA-33, "Removal and Installation"
.
2. Disconnect high-pressure pipe from expansion valve.
CAUTION:
Cap or wrap the joint of the A/C piping and expansion valve with suitable material such as vinyl
tape to avoid the entry of air.
3. Remove high-pressure pipe bolt and disconnect high-pressure pipe from the condenser.
CAUTION:
Cap or wrap the joint of the A/C piping and condenser with suitable material such as vinyl tape to
avoid the entry of air.
4. Loosen the clip and remove high-pressure pipe from the vehicle.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
• Do not reuse O-rings.
• Apply A/C oil to the O-ring of the high-pressure pipe for installation.
• After charging the A/C refrigerant, check for leaks. Refer to
HA-36
< REMOVAL AND INSTALLATION >
EXPANSION VALVE
EXPANSION VALVE
Removal and Installation
INFOID:0000000009269759
CAUTION:
Perform oil return operation before each refrigeration system disassembly. However, if a large amount
of refrigerant or oil is detected, do not perform oil return operation. Refer to
REMOVAL
1. Use refrigerant collecting equipment (for HFC-134a) to discharge the refrigerant. Refer to
2. Disconnect low-pressure flexible hose from expansion valve. Refer to
HA-33, "Removal and Installation"
3. Remove the air cleaner assembly. Refer to
EM-25, "Removal and Installation"
4. Disconnect high-pressure pipe from expansion valve. Refer to
HA-35, "Removal and Installation"
5. Remove the bolts and the expansion valve.
CAUTION:
Cap or wrap the joint of the evaporator and expansion valve with suitable material such as vinyl
tape to avoid the entry of air.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
• Do not reuse O-rings.
• Apply A/C oil to the O-rings of the low-pressure flexible hose and high-pressure pipe for installation.
• After charging A/C refrigerant, check for leaks. Refer to
.
LIQUID TANK
HA-37
< REMOVAL AND INSTALLATION >
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
LIQUID TANK
Removal and Installation of Liquid Tank
INFOID:0000000009269760
The liquid tank is only serviced as part of the condenser and liquid tank assembly. Refer to
.
HA-38
< REMOVAL AND INSTALLATION >
REFRIGERANT PRESSURE SENSOR
REFRIGERANT PRESSURE SENSOR
Removal and Installation
INFOID:0000000009269761
CAUTION:
Perform oil return operation before each refrigeration system disassembly. However, if a large amount
of refrigerant or oil is detected, do not perform oil return operation. Refer to
REMOVAL
1. Use refrigerant collecting equipment (for HFC-134a) to discharge the refrigerant. Refer to
2. Clean refrigerant pressure sensor and its surrounding area and remove dust and rust from refrigerant
pressure sensor.
CAUTION:
Be sure to clean carefully.
3. Disconnect the harness connector from the refrigerant pressure sensor.
4. Remove the refrigerant pressure sensor.
CAUTION:
• Be careful not to damage liquid tank.
• Be careful not to damage core surface of condenser.
• Cap or wrap the joint of the condenser and liquid tank with suitable material such as vinyl tape to
avoid the entry of air.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
• Do not reuse O-rings.
• Apply A/C oil to the O-rings of the high-pressure pipe and refrigerant pressure sensor for installa-
tion.
• After charging the A/C refrigerant, check for leaks. Refer to