Nissan Primera P11. Manual — part 347
YEL906C
POWER DOOR LOCK
Wiring Diagram — D/LOCK — (Cont’d)
EL-255
Trouble Diagnoses
PRELIMINARY CHECK
CHECK-IN
Open all windows and remove
key from ignition key cylinder.
Does power door lock operate
properly?
Yes
왘
No (All doors)
Power door lock does not operate by using;
— any switch.
. . . . . . . . . . . . . . . . . ..
— driver side lock knob switch and/or key
cylinder.
. . . . . . . . . . . . . . . . . ..
— passenger side lock knob switch and/or
key cylinder.
★
왘
SYMPTOM 1
왘
SYMPTOM 2
왘
SYMPTOM 3
No (Specific door)
SYMPTOM 4
Insert key to ignition key
cylinder, open any door and
lock the door using driver side
knob lock switch.
Does key reminder system
operate properly?
Yes
왘
No
SYMPTOM 5
INSPECTION END
After performing preliminary check, go to symptom chart on the next page.
★
When one or more doors are opened, with lock knob on passenger door setting to LOCK, will lock pas-
senger door only. (Power door lock system will not operate.)
왔
왔
왔
왔
왔
POWER DOOR LOCK
EL-256
Before starting trouble diagnoses below, perform preliminary check, EL-256.
Symptom numbers in the symptom chart correspond with those of Preliminary check.
SYMPTOM CHART
REFERENCE PAGE
SYMPTOM
Power
supply
and
ground
circuit
check
Procedure
1
(Door
unlock
sensor
check)
Procedure
2
(Door
key
cylinder
switch
check)
Procedure
3
(Door
lock
actuator
check)
Procedure
4
(Door
switch
check)
Procedure
5
(Key
switch
check)
1
Power door lock does not operate
using any switch.
X
X
2
Power door lock does not operate
with lock/unlock switch.
X
3
Power door lock does not operate
with door key cylinder switch.
X
4
Specific door lock acutator does
not operate.
X
5
*Key reminder system does not
operate.
X
X
X: Applicable
*: Make sure the power door lock and key reminder system operate properly.
POWER DOOR LOCK
Trouble Diagnoses (Cont’d)
EL-257
POWER SUPPLY AND GROUND CIRCUIT CHECK
Main power supply circuit check
Terminals
Ignition switch position
䊝
䊞
LOCK
ACC
ON
쑗
9
Ground
Battery
voltage
Battery
voltage
Battery
voltage
Ground circuit check
Terminals
Continuity
쑗
16
- Ground
Yes
YEL445B
Time control
unit connector
YEL431B
Time control unit connector
POWER DOOR LOCK
Trouble Diagnoses (Cont’d)
EL-258