Nissan Pathfinder. Manual — part 362
DLK-214
< DTC/CIRCUIT DIAGNOSIS >
HALF LATCH SWITCH
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK HALF LATCH SWITCH
DLK-214, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace back door lock assembly. Refer to
DLK-308, "DOOR LOCK : Removal and Installation"
5.
CHECK INTERMITTENT INCIDENT
GI-49, "Intermittent Incident"
>> Inspection End.
Component Inspection
INFOID:0000000009175775
COMPONENT INSPECTION
1.
CHECK HALF LATCH SWITCH
1. Turn ignition switch OFF.
2. Disconnect back door lock assembly connector.
3. Check continuity between back door lock assembly terminals.
Is the inspection result normal?
YES
>> Inspection End.
NO
>> Replace back door lock assembly. Refer to
DLK-308, "DOOR LOCK : Removal and Installation"
Back door lock assembly
Ground
Continuity
Connector
Terminal
D557
3
Yes
Back door lock assembly
Condition
Continuity
Terminal
6
8
Back door
Open
Yes
Fully closed/Half
latch
No
TOUCH SENSOR
DLK-215
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
TOUCH SENSOR
RH
RH : Component Function Check
INFOID:0000000009175776
1.
CHECK FUNCTION
1. Select AUTOMATIC BACK DOOR CONTROL MODULE using CONSULT.
2. Select TOUCH SEN RH in DATA MONITOR mode.
3. Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Touch sensor RH is OK.
NO
>> Refer to
DLK-215, "RH : Diagnosis Procedure"
RH : Diagnosis Procedure
INFOID:0000000009175777
Regarding Wiring Diagram information, refer to
.
1.
CHECK TOUCH SENSOR INPUT SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between touch sensor RH harness connector and automatic back door control module har-
ness connector.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK TOUCH SENSOR RH CIRCUIT
1. Disconnect automatic back door control module and touch sensor RH connector.
2. Check continuity between automatic back door control module harness connector and touch sensor RH
harness connector.
3. Check continuity between automatic back door control module harness connector and ground.
Monitor item
Condition
Status
TOUCH SEN RH
Touch sensor RH
Other than below
OFF
Detect obstruction
ON
(+)
(–)
Condition
Voltage
(Approx.)
Touch sensor RH
Automatic back door control mod-
ule
Connector
Terminal
Connector
Terminal
D555
1
B55
13
Touch sensor
RH
Detect obstruc-
tion
1.8 – 5 V
Other than
above
2.72 – 7.27 V
Automatic back door control module
Touch sensor RH
Continuity
Connector
Terminal
Connector
Terminal
B55
1
D555
1
Yes
Automatic back door control module
Ground
Continuity
Connector
Terminal
B55
1
No
DLK-216
< DTC/CIRCUIT DIAGNOSIS >
TOUCH SENSOR
Is the inspection result normal?
YES
>> Replace automatic back door control module. Refer to
DLK-321, "Removal and Installation"
.
NO
>> Repair or replace harness.
3.
CHECK TOUCH SENSOR RH GROND CIRCUIT
1. Disconnect automatic back door control module and touch sensor RH connector.
2. Check continuity between automatic back door control module harness connector and touch sensor RH
harness connector.
3. Check continuity between automatic back door control module harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK TOUCH SENSOR RH GROND CIRCUIT 2
1. Connect automatic back door control module and touch sensor RH connector.
2. Check voltage between automatic back door control module harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair or replace harness.
5.
CHECK TOUCH SENSOR RH
DLK-216, "RH : Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Replace touch sensor RH. Refer to
DLK-309, "TOUCH SENSOR : Removal and Installation"
6.
CHECK INTERMITTENT INCIDENT
GI-49, "Intermittent Incident"
>> Inspection End.
RH : Component Inspection
INFOID:0000000009175778
1.
CHECK TOUCH SENSOR RH
1. Turn ignition switch OFF.
2. Disconnect touch sensor RH connector.
3. Check resistance between touch sensor RH terminals.
Automatic back door control module
Touch sensor RH
Continuity
Connector
Terminal
Connector
Terminal
B55
13
D555
2
Yes
Automatic back door control module
Ground
Continuity
Connector
Terminal
B55
13
No
(+)
(–)
Voltage
(Approx.)
Automatic back door control module
Connector
Terminal
B55
13
Ground
0.01 – 0 V
TOUCH SENSOR
DLK-217
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> Inspection End.
NO
>> Replace touch sensor RH. Refer to
DLK-309, "TOUCH SENSOR : Removal and Installation"
LH
LH : Component Function Check
INFOID:0000000009175779
1.
CHECK FUNCTION
1. Select AUTOMATIC BACK DOOR CONTROL MODULE using CONSULT.
2. Select TOUCH SEN LH in DATA MONITOR mode.
3. Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Touch sensor LH is OK.
NO
>> Refer to
DLK-217, "LH : Diagnosis Procedure"
.
LH : Diagnosis Procedure
INFOID:0000000009175780
Regarding Wiring Diagram information, refer to
.
1.
CHECK TOUCH SENSOR INPUT SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between touch sensor LH harness connector and automatic back door control module har-
ness connector.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK TOUCH SENSOR LH CIRCUIT
1. Disconnect automatic back door control module and touch sensor LH connector.
2. Check continuity between automatic back door control module harness connector and touch sensor LH
harness connector.
Touch sensor RH
Condition
Resistance
(Approx.)
Terminal
1
2
Touch sensor RH
Detect obstruction
380 – 420 k
Ω
Other than above
0.95 – 1.05 k
Ω
Monitor item
Condition
Status
TOUCH SEN LH
Touch sensor LH
Other than below
OFF
Detect obstruction
ON
(+)
(–)
Condition
Voltage
(Approx.)
Touch sensor LH
Automatic back door control mod-
ule
Connector
Terminal
Connector
Terminal
D556
1
B55
13
Touch sensor
LH
Detect obstruc-
tion
1.8 – 5 V
Other than
above
2.72 – 7.27 V
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.