Almera Tino V10 (2003 year). Manual — part 177
Rear Door
=NLEL0573S1102
1
CHECK OUTPUT SIGNAL FOR SUPER LOCK ACTUATOR
Check voltage between smart entrance control unit harness connector M101 terminal 55 (W/B), 52 (Y) and ground.
SIIA1609E
MTBL1716
OK or NG
OK
©
GO TO 2.
NG
©
Replace smart entrance control unit.
2
CHECK SUPER LOCK ACTUATOR
1. Disconnect door lock actuator assembly connector.
Door lock actuator connector (Rear LH side): D55
Door lock actuator connector (Rear RH side): D65
2. Apply 12V direct current to door lock actuator assembly and check operation.
YEL841D
MTBL1555
OK or NG
OK
©
Check harness for open or short between smart entrance control unit and super lock
actuator.
NG
©
Replace super lock actuator (door lock actuator).
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK — SUPER LOCK —
Trouble Diagnosis (Cont’d)
EL-321
Component Parts and Harness Connector
Location
NLEL0574
YEL362E
System Description
NLEL0480
INPUTS
NLEL0480S06
Power is supplied at all times
I
to smart entrance control unit terminal 51 and
I
through 15A fuse [No. 5, located in the fuse block (J/B)], and
I
to key switch terminal 1
I
through 10A fuse [No. 12, located in the fuse block (J/B)]
When the key switch is ON (ignition key is inserted in key cylinder), power is supplied
I
through key switch terminal 2
I
to smart entrance control unit terminal 5.
When the door switch driver side is ON (door is OPEN), ground is supplied
I
to smart entrance control unit terminal 43
I
through door switch driver side terminal 2
I
to door switch driver side terminal 1
I
through body grounds B24, B30 and D89.
When the door switch passenger side is ON (door is OPEN), ground is supplied
I
to smart entrance control unit terminal 44
I
through door switch passenger side terminal 1
When the all doors switches are ON (door is OPEN), ground is supplied
I
to smart entrance control unit terminal 44
I
through front door switches terminal 1
I
to front door switches case grounds, and
I
through rear door switches terminal 1
I
to rear door switches case grounds
When lock/unlock switch is LOCK, ground is supplied
I
to power window main switch terminal 3
I
through body grounds B24, B30 and D89.
Door lock or unlock operation signal is supplied
I
through power window main switch terminal 14
I
to smart entrance control unit terminal 13.
MULTI-REMOTE CONTROL SYSTEM
Component Parts and Harness Connector Location
EL-322
Door lock or unlock operation signal is supplied
I
through power window main switch terminal 7
I
to smart entrance control unit terminal 14.
Remote controller signal is inputted to smart entrance control unit (The antenna of the system is combined
with smart entrance control unit).
FUNCTION
NLEL0480S01
Multi-remote control system has the following function.
I
Door lock (and set super lock)
I
Door unlock (and release super lock)
I
Hazard reminder
LOCK OPERATION
NLEL0480S02
To lock door by multi-remote controller, the key switch must be at OFF.
When the LOCK signal is input to smart entrance control unit, the antenna of the system is combined with
time control unit.
Then smart entrance control unit controls to lock doors and set super lock (models with super lock).
UNLOCK OPERATION
NLEL0480S03
Normal Mode
NLEL0480S0301
When UNLOCK signal is input to smart entrance control unit, the antenna of the system is combined with smart
entrance control unit.
Smart entrance control unit controls to unlock doors and release super lock (models with super lock).
Anti Hi-jack Mode
NLEL0480S0302
When the UNLOCK signal is input to smart entrance control unit (the antenna of the system is combined with
time control unit)
Smart entrance control unit controls to unlock driver’s door and release super lock (models with super lock).
Then, if an unlock signal is sent from the remote controller again within 5 seconds, all other doors will be
unlocked.
Unlock operation mode can be changed to “SELECTIVE UNLOCK” by CONSULT-II (EL-271).
HAZARD REMINDER
NLEL0480S04
When the doors are locked or unlocked by multi-remote controller, supply power to turn lamps hazard reminder
flashes as follows
I
Lock operation: Flash once
I
Unlock operation: Flash twice
AUTO DOOR LOCK OPERATION
NLEL0480S07
Auto lock function signal is sent for operation when any of the following signals are not sent within 5 minutes
after the unlock signal is sent from the multi-remote controller:
I
when door switch is turned ON for open
I
when the ignition switch is turned ON
I
when the lock signal is sent from the multi-remote controller
I
when ignition switch is inserted in ignition key cylinder
Auto door lock mode can be changed to “AUTO RE-LOCK” by CONSULT-II (EL-271).
MULTI-REMOTE CONTROLLER ID CODE ENTRY
NLEL0480S05
A maximum of four remote controllers can be entered.
To enter ID code entry, the following signals must be input to the time control unit.
I
Ignition switch (ON)
I
Signal from remote controller
For detailed procedure, refer to “ID Code Entry Procedure” in EL-336.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
System Description (Cont’d)
EL-323
Schematic
NLEL0692
YEL473E
MULTI-REMOTE CONTROL SYSTEM
Schematic
EL-324
Wiring Diagram — MULTI —
NLEL0481
FIG. 1
NLEL0481S06
YEL016E
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Wiring Diagram — MULTI —
EL-325
FIG. 2
NLEL0481S07
YEL017E
MULTI-REMOTE CONTROL SYSTEM
Wiring Diagram — MULTI — (Cont’d)
EL-326
FIG. 3
NLEL0481S08
YEL474E
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Wiring Diagram — MULTI — (Cont’d)
EL-327
MBIB0906E
CONSULT-II Inspection Procedure
NLEL0685
1.
Turn ignition switch “OFF”.
2.
Connect CONSULT-II to the data link connector.
MBIB0233E
3.
Turn ignition switch “ON”.
4.
Touch “START (NISSAN BASED VHCL)”.
SIIA1678E
5.
Touch “SMART ENTRANCE”.
SIIA1679E
6.
Touch “KEYLESS ENTRY”.
SIIA1677E
7.
Select diagnosis mode.
“DATA MONITOR” and “WORK SUPPORT” are available.
MULTI-REMOTE CONTROL SYSTEM
CONSULT-II Inspection Procedure
EL-328
CONSULT-II Application Items
NLEL0686
DATA MONITOR
Monitored Item
Description
IGNITION SW
Indicates [ON/OFF] condition of ignition switch in ON position.
TRUNK OPEN SW
Indicates [ON/OFF] condition of back door switch.
RKE LOCK
Indicates [ON/OFF] condition of lock signal from remote controller.
RKE UNLOCK
Indicates [ON/OFF] condition of unlock signal from remote controller.
RKE SEL UNLOCK
Indicates [ON/OFF] condition of select unlock signal from remote controller.
RKE TRUNK REL
Indicates [ON/OFF] condition of back door open signal from back door release switch.
BATTERY CHECK
Indicates [OK/NG] condition of remote controller battery.
MODE
Indicates [CMFRT/SCRTY] condition of multi-remote control system.
WORK SUPPORT
Test Item
Description
KEYLESS CHECK
It can be checked whether remote controller ID code is registered or not in this mode.
KEYLESS REGISTRATION
Remote controller ID code can be registered.
KEYLESS DI FLASH
This mode can be setting hazard reminder function.
I
MODE 1: Nothing
I
MODE 2: Lock operation only
I
MODE 3: Unlock operation only
I
MODE 4: Both lock and unlock operation
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
CONSULT-II Application Items
EL-329
Trouble Diagnoses
NLEL0482
SYMPTOM CHART
=NLEL0482S01
NOTE:
Always check remote controller battery before replacing remote
controller.
Symptom
Diagnoses/service procedure
Reference
page
(EL-
)
No doors can be locked or unlocked by remote
control operation.
(Make sure that power door lock operates properly.
If NG, check power door lock.)
1. Remote controller battery check
2. Power supply and ground circuit for time control unit check
3. Replace remote controller. Refer to ID Code Entry Proce-
dure.
The new ID of remote controller cannot be entered. 1. Remote controller battery check
2. Power supply and ground circuit for time control unit check
3. Ignition “ON” power supply circuit for time control unit
4. Replace remote controller. Refer to ID Code Entry Proce-
dure.
Hazard reminder does not activate properly when
pressing lock or unlock button of remote controller.
1. Remote controller battery
2. Hazard reminder check
3. Replace remote controller. Refer to ID Code Entry Proce-
dure.
Auto door lock does not activate properly. (All other
multi-remote control system functions are OK.)
1. Check auto door lock operation setting.
2. Replace smart entrance control unit.
—
Interior room lamp does not activate properly.
1. Check interior room lamp operation.
2. Check door switch.
3. Replace smart entrance control unit.
—
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses
EL-330
POWER SUPPLY AND GROUND CIRCUIT CHECK
=NLEL0482S03
1
CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect smart entrance control unit connector.
3. Check voltage between smart entrance control unit harness connector M101 terminal 56 (R/B) and ground.
YEL363E
MTBL1717
OK or NG
OK
©
GO TO 2.
NG
©
Check the following.
I
15A fuse [No. 5, located in fuse and fusible link box (J/B)]
I
Harness for open or short between smart entrance control unit and fuse
2
CHECK GROUND CIRCUIT
Check continuity between smart entrance control unit harness connector M101 terminal 53 (B) and ground.
SIIA1565E
MTBL1718
OK or NG
OK
©
Power supply and ground circuit is OK.
NG
©
Check smart entrance control unit ground circuit for open or short.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont’d)
EL-331
REMOTE CONTROLLER BATTERY AND FUNCTION
CHECK
=NLEL0482S02
1
CHECK REMOTE CONTROLLER BATTERY
Remove battery (refer to EL-339) and measure voltage across battery positive and negative terminals, (+) and (−) with
using 300
Ω
resistor as shown in figure.
Voltage [V]:
2.5 - 3.0
NOTE:
Remote controller does not function if battery is not set correctly.
SEL237W
OK or NG
OK
©
Check remote controller battery terminals for corrosion or damage.
NG
©
Replace battery.
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont’d)
EL-332
IGNITION “ON” POWER SUPPLY CIRCUIT FOR SMART
ENTRANCE CONTROL UNIT
=NLEL0482S17
1
CHECK IGNITION “ON” POWER SUPPLY CIRCUIT FOR SMART ENTRANCE CONTROL UNIT
1. Disconnected time control unit harness connector.
2. Check voltage between smart entrance control unit terminal 29 (Y/G) and ground.
YEL364E
OK or NG
OK
©
Ignition “ON” power supply circuit is OK.
NG
©
Check the following.
I
10A fuse [No. 10, located in fuse block (J/B)]
I
Harness for open or short between smart entrance control unit and fuse.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont’d)
EL-333
HAZARD REMINDER CHECK
=NLEL0482S18
1
CHECK HAZARD WARNING LAMP
Check if hazard warning lamp flashes with hazard switch.
Does hazard warning lamp operate?
Yes
©
GO TO 2.
No
©
Check hazard warning lamp circuit.
2
CHECK HAZARD REMINDER OPERATION
Check the following at when push the remote controller switch.
Check voltage between smart entrance control unit harness connector M101 terminal 63 (G/Y), 64 (G/B) and ground.
YEL365E
MTBL1515
OK or NG
OK
©
Check harness for open or short between smart entrance control unit and hazard switch.
NG
©
Check the following before replacing the smart entrance control unit.
I
Multi-remote controller ID is registered.
I
Multi-remote controller battery is OK.
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont’d)
EL-334
INTERIOR ROOM LAMP OPERATION CHECK
=NLEL0482S22
1
CHECK ROOM INTERIOR LAMP
Check if the interior room lamp switch is in the “ON” position and the lamp illuminates.
Does interior room lamp illuminate?
Yes
©
GO TO 2.
No
©
Check the following.
I
Harness for open or short between smart entrance control unit and interior room lamp
I
Interior room lamp
2
CHECK INTERIOR ROOM LAMP OPERATION
Push unlock button of multi-remote controller with all doors closed and driver’s door locked, and check voltage between
smart entrance control unit harness connector M100 terminal 28 (R/Y) and ground.
YEL366E
OK or NG
OK
©
System is OK.
NG
©
Check the following before replacing the smart entrance control unit.
I
Multi-remote controller ID is registered.
I
Multi-remote controller battery is OK.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont’d)
EL-335
MBIB0906E
ID Code Entry Procedure
=NLEL0483
REMOTE CONTROLLER ID SET UP WITH CONSULT-II
NLEL0483S02
NOTE:
If a remote controller is lost, the ID code of the lost remote
controller must be erased to prevent unauthorized use. When
the ID code of a lost remote controller is not known, all con-
troller ID codes should be erased. After all ID codes are
erased, the ID codes of all remaining and/or new remote con-
trollers must be re-registered.
1.
Turn ignition switch “OFF”.
2.
Connect “CONSULT-II” to the data link connector.
MBIB0233E
3.
Turn ignition switch “ON”.
4.
Touch “START”.
SIIA1678E
5.
Touch “SMART ENTRANCE”.
YEL324E
6.
Touch “KEYLESS ENTRY”.
SIIA1677E
7.
Touch “WORK SUPPORT”.
MULTI-REMOTE CONTROL SYSTEM
ID Code Entry Procedure
EL-336