Almera Tino V10 (2003 year). Manual — part 173
The subsequent operation is the same as the front power window sub-switch operation.
FRONT POWER WINDOW SUB-SWITCH OPERATION
Power is supplied
I
through front power window sub-switch (1, 2)
I
to power window regulator front passenger side (2, 1).
Ground is supplied
I
to front passenger side power window regulator (1, 2)
I
through front power window sub-switch (2, 1)
I
to front power window sub-switch (4, 3)
I
through power window main switch (6, 5).
Then, the motor raises or lowers the window until the switch is released.
Rear Door
NLEL0498S0103
Rear door windows will raise and lower in the same manner as passenger’s door window.
POWER WINDOW LOCK
NLEL0498S02
The power window lock is designed to lock operation of all windows except for driver’s door window.
When the lock switch is pressed to lock position, ground of the sub-switches in the power window main switch
is disconnected. This prevents the power window motors from operating.
AUTO OPERATION
NLEL0498S03
The power window AUTO feature enables the driver to open the driver’s window without holding the window
switch in the down position.
The AUTO feature operates on the driver’s window.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER WINDOW
System Description (Cont’d)
EL-257
Schematic
NLEL0499
YEL996D
POWER WINDOW
Schematic
EL-258
Wiring Diagram — WINDOW —
NLEL0500
YEL997D
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER WINDOW
Wiring Diagram — WINDOW —
EL-259
YEL998D
POWER WINDOW
Wiring Diagram — WINDOW — (Cont’d)
EL-260
YEL999D
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER WINDOW
Wiring Diagram — WINDOW — (Cont’d)
EL-261
YEL001E
POWER WINDOW
Wiring Diagram — WINDOW — (Cont’d)
EL-262
Trouble Diagnoses
NLEL0501
Symptom
Possible cause
Repair order
None of the power windows can be
operated using any switch.
1. 10A fuse
2. 30A fusible link, M4 circuit
breaker
3. Power window relay
4. Ground circuit
5. Power window main switch
1. Check 10A fuse [No. 10, located in fuse block (J/B)]
Turn ignition switch “ON” and verify positive battery
voltage is present at terminal 1 of power window
relay.
2. Check 30A fusible link (letter B, located in fuse and
fusible link box) and M4 circuit breaker. Verify posi-
tive battery voltage is present at terminal 5 of power
window relay.
3. Check power window relay.
4. Check the following:
a. Check ground circuit of power window main switch.
b. Check power window relay ground circuit.
5. Check power window main switch.
Driver side power window cannot
be operated but other windows can
be operated.
1. Driver side power window regu-
lator circuit
2. Driver side power window regu-
lator
3. Power window main switch
1. Check harness between power window main switch
and driver side power window regulator for open or
short circuit.
2. Check driver side power window regulator.
3. Check power window main switch.
One or more power windows
except driver’s side window cannot
be operated.
1. Power window sub-switches
2. Power window regulators
3. Power window main switch
4. Power window circuit
1. Check power window sub-switch.
2. Check power window regulator.
3. Check power window main switch.
4. Check the following.
a. Check harness between the power window relay
terminal 3 and power window sub-switch terminal 5.
b. Check harnesses between power window main
switch and power window sub-switch for open/short
circuit.
c. Check harnesses between power window sub-
switch and power window regulator for open/short
circuit.
Power windows except driver’s side
window cannot be operated using
power window main switch but can
be operated by power window sub-
switch.
1. Power window main switch
1. Check power window main switch.
Driver side power window auto-
matic operation does not function
properly.
1. Power window main switch
1. Check power window main switch.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER WINDOW
Trouble Diagnoses
EL-263
Component Parts and Harness Connector
Location
NLEL0526
For details, refer to “ELECTRICAL UNIT LOCATION” (EL-594) and “HARNESS LAYOUT” (EL-600).
System Description
NLEL0502
OPERATION
NLEL0502S02
Power door lock/unlock operation by door key cylinder
I
With the key inserted into front door key cylinder, turning it to LOCK will lock all doors.
I
With the key inserted into front door key cylinder, turning it to UNLOCK will unlock all doors.
Power door lock/unlock operation by multi-remote controller (If equipped)
I
Pressing multi-remote controller LOCK button will lock all doors.
I
Pressing multi-remote controller UNLOCK button once will unlock driver door. Then, if an unlock signal is
sent from the remote controller again within 5 seconds, all other doors will be unlocked.
Power door lock/unlock operation by lock/unlock switch
I
With lock/unlock switch on driver door trim setting to LOCK will lock all doors.
I
With lock/unlock switch on driver door trim setting to UNLOCK will unlock all doors.
Key reminder system
I
If the ignition key is in the ignition key cylinder and driver door is open, setting lock/unlock switch, lock
knob, key or multi-remote controller to “LOCK” locks the door once but then immediately unlocks all doors.
(signal from door unlock sensor driver side)
POWER DOOR LOCK
Component Parts and Harness Connector Location
EL-264
Schematic
NLEL0503
YEL002E
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK
Schematic
EL-265
Wiring Diagram — D/LOCK —
NLEL0504
FIG. 1
NLEL0504S14
YEL004E
POWER DOOR LOCK
Wiring Diagram — D/LOCK —
EL-266
FIG. 2
NLEL0504S15
YEL005E
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK
Wiring Diagram — D/LOCK — (Cont’d)
EL-267
FIG. 3
NLEL0504S16
YEL006E
POWER DOOR LOCK
Wiring Diagram — D/LOCK — (Cont’d)
EL-268
FIG. 4
NLEL0504S17
YEL007E
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK
Wiring Diagram — D/LOCK — (Cont’d)
EL-269
MBIB0906E
Trouble Diagnosis
NLEL0572
CONSULT-II INSPECTION PROCEDURE “DOOR
LOCKING”
NLEL0572S01
1.
Turn ignition switch “OFF”.
2.
Connect CONSULT-II to the data link connector.
MBIB0233E
3.
Turn ignition switch “ON”.
4.
Touch “START (NISSAN BASED VHCL)”.
SIIA1678E
5.
Touch “SMART ENTRANCE”.
6.
Touch “DOOR LOCKING” or “TRUNK RELEASE”.
SIIA1677E
7.
Select diagnosis mode.
“DATA MONITOR” and “WORK SUPPORT” are available.
POWER DOOR LOCK
Trouble Diagnosis
EL-270
CONSULT-II APPLICATION ITEMS
=NLEL0572S02
Door Locking
NLEL0572S0201
DATA MONITOR
Monitored Item
Description
IGNITION SW
Indicates [ON/OFF] condition of ignition switch.
DOOR SW DR RR
Indicates [ON/OFF] condition of rear door switch (driver side).
DOOR SW AS RR
Indicates [ON/OFF] condition of rear door switch (passenger side).
AS DOOR SW
Indicates [ON/OFF] condition of front door switch (passenger side).
DR DOOR SW
Indicates [ON\OFF] condition of front door switch (driver side).
CDL LOCK SW
Indicates [ON/OFF] condition of lock signal from door lock/ unlock switch.
CDL UNLOCK SW
Indicates [ON/OFF] condition of unlock signal from door lock/ unlock switch.
RKE LOCK
Indicates [ON/OFF] condition of lock signal from remote controller.
RKE UNLOCK
Indicates [ON/OFF] condition of unlock signal from remote controller.
RKE SEL UNLOCK
Indicates [ON/OFF] condition of select unlock signal from remote controller.
KEY CYL LK
Indicates [ON/OFF] condition of lock signal from door key cylinder.
KEY CYL UNLK
Indicates [ON/OFF] condition of unlock signal from door key cylinder.
WORK SUPPORT
Monitored Item
Description
AUTO RE-LOCK
Auto re-lock function can be changed in this mode. The re-lock mode will be changed when
“CHANGE MODE” on CONSULT-II screen is touched.
SELECTIVE UNLOCK
Selective unlock function can be changed in this mode. The unlock mode will be changed when
“CHANGE SET” on CONSULT-II screen is touched.
SYMPTOM CHART
NLEL0572S03
First perform the “SELF-DIAG RESULTS” in “SMART ENTRANCE”
with CONSULT-II, when perform the each trouble diagnosis. Refer
to EL-270, “CONSULT-II INSPECTION PROCEDURE”.
Symptom
Malfunctioning system
Reference
page
Power door lock does not operate using any switch
Power supply and ground circuit check
Door lock actuator check
If above systems are OK, replace smart entrance con-
trol unit.
—
Power door lock does not operate with lock/unlock
switch.
Door lock/unlock switch check
If above system is OK, replace smart entrance control
unit.
—
Specific door lock actuator does not operate.
Door lock actuator check
*Key reminder system does not operate.
Door switch check
If above system is OK, replace smart entrance control
unit.
—
*: Make sure the power door lock system operates properly.
GI
MA
EM
LC
EC
FE
CL
MT
AT
AX
SU
BR
ST
RS
BT
HA
SC
IDX
POWER DOOR LOCK
Trouble Diagnosis (Cont’d)
EL-271
POWER SUPPLY AND GROUND CIRCUIT CHECK
=NLEL0572S04
1
CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect smart entrance control unit connector.
3. Check voltage between smart entrance control unit harness connector M101 terminal 49 (W/L), 56 (R/B) and ground.
SIIA1564E
MTBL1676
OK or NG
OK
©
GO TO 2.
NG
©
Check the following.
I
30A fusible link (letter B, located in fuse and fusible link box)
I
Circuit breaker
I
15A fuse [No. 5, located in fuse block (J/B)]
I
Harness for open or short between smart entrance control unit and fuse
I
Harness for open or short between smart entrance control unit and circuit breaker
I
Harness for open or short between circuit breaker and fusible link
POWER DOOR LOCK
Trouble Diagnosis (Cont’d)
EL-272