Nissan X-Trail 32. Manual — part 535
BACK DOOR REQUEST SWITCH
DLK-481
< DTC/CIRCUIT DIAGNOSIS >
[TYPE 2]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
BACK DOOR REQUEST SWITCH
Description
INFOID:0000000010717535
Transmits lock/unlock operation to BCM.
Component Function Check
INFOID:0000000010717536
1.
CHECK FUNCTION
1.
Turn ignition switch ON.
2.
Select “INTELLIGENT KEY” of “BCM” using CONSULT.
3.
Select “REQ SW BD/TR” in “DATA MONITOR” mode.
4.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Back door request switch is OK.
NO
>> Refer to
DLK-481, "Diagnosis Procedure"
Diagnosis Procedure
INFOID:0000000010717537
1.
CHECK BCM OUTPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect back door opener switch assembly connector.
3.
Check voltage between back door opener switch assembly harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK BACK DOOR REQUEST SWITCH CIRCUIT
1.
Disconnect BCM connector.
2.
Check continuity between BCM harness connector and back door opener switch assembly harness con-
nector.
3.
Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-121, "Removal and Installation"
.
NO
>> Repair or replace harness.
3.
CHECK BACK DOOR REQUEST SWITCH GROUND CIRCUIT
Monitor item
Condition
Status
REQ SW -BD/TR
Back door request switch
Pressed
ON
Released
OFF
(+)
(–)
Voltage
Back door opener switch assembly
Connector
Terminal
D169
4
Ground
9 – 16 V
BCM
Back door opener switch assembly
Continuity
Connector
Terminal
Connector
Terminal
B47
6
D169
4
Existed
BCM
Ground
Continuity
Connector
Terminal
B47
6
Not existed
DLK-482
< DTC/CIRCUIT DIAGNOSIS >
[TYPE 2]
BACK DOOR REQUEST SWITCH
Check continuity between back door opener switch assembly harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK BACK DOOR REQUEST SWITCH
DLK-482, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace back door opener switch assembly.
5.
CHECK INTERMITTENT INCIDENT
GI-44, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000010717538
1.
CHECK BACK DOOR REQUEST SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect back door opener switch assembly connector.
3.
Check back door opener switch assembly terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace back door opener switch assembly.
Back door opener switch assembly
Ground
Continuity
Connector
Terminal
D169
3
Existed
Back door opener switch assembly
Condition
Continuity
Terminal
4
3
Back door opener request switch
Pressed
Existed
Released
Not existed
CLOSE SWITCH
DLK-483
< DTC/CIRCUIT DIAGNOSIS >
[TYPE 2]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
CLOSE SWITCH
Component Function Check
INFOID:0000000010717539
1.
CHECK FUNCTION
1.
Turn ignition switch ON.
2.
Select “AUTO BACK DOOR” using CONSULT.
3.
Select “CLOSE SW” in “DATA MONITOR” mode.
4.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Close switch is OK.
NO
>> Refer to
DLK-483, "Diagnosis Procedure"
Diagnosis Procedure
INFOID:0000000010717540
1.
CHECK CLOSE SWITCH INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect back door lock assembly connector.
3.
Check voltage between back door lock assembly harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK CLOSE SWITCH CIRCUIT
1.
Disconnect automatic back door control unit connector.
2.
Check continuity between automatic back door control unit harness connector and back door lock assem-
bly harness connector.
3.
Check continuity between automatic back door control unit harness connector and ground.
Is the inspection result normal?
YES
>> Replace automatic back door control unit. Refer to
DLK-633, "Removal and Installation"
.
NO
>> Repair or replace harness.
3.
CHECK CLOSE SWITCH GROUND CIRCUIT
Check continuity between back door lock assembly harness connector and ground.
Monitor item
Condition
Status
CLOSE SW
Back door
Closure operation
ON
Other than above
OFF
(+)
(–)
Voltage
(Approx.)
Back door lock assembly
Connector
Terminal
D172
5
Ground
12.2 V
Automatic back door control unit
Back door lock assembly
Continuity
Connector
Terminal
Connector
Terminal
B24
5
D172
5
Existed
Automatic back door control unit
Ground
Continuity
Connector
Terminal
B24
5
Not existed
DLK-484
< DTC/CIRCUIT DIAGNOSIS >
[TYPE 2]
CLOSE SWITCH
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK INTERMITTENT INCIDENT
GI-44, "Intermittent Incident"
>> INSPECTION END
Back door lock assembly
Ground
Continuity
Connector
Terminal
D172
8
Existed
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.