Nissan X-Trail 32. Manual — part 1376
PERFORMANCE TEST
HA-163
< BASIC INSPECTION >
[R9M (FOR RUSSIA)]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
Fresh air
High-pressure (Discharge side)
kPa (bar, kg/cm
2
, psi)
Low-pressure (Suction side)
kPa (bar, kg/cm
2
, psi)
Relative humidity
%
Air temperature
°
C (
°
F)
50 – 70
25 (77)
926 – 1,133
(9.3 – 11.3, 9.5 – 11.6, 134.3 –
164.2)
196 – 240
(2.0 – 2.4, 2.0 – 2.5, 28.4 – 34.8)
30 (86)
1,070 -– 1,308
(10.7 – 13.1, 10.9 – 13.3, 155.1 –
189.6)
233 – 285
(2.3 – 2.9, 2.4 – 2.9, 33.8 – 41.3)
35 (95)
1,091 – 1,332
(10.9 – 13.3, 11.1 – 13.6, 158.1 –
193.2)
278 – 340
(2.8 – 3.4, 2.8 – 3.5, 40.3 – 49.2)
40 (104)
1,292 – 1,579
(12.9 – 15.8, 13.2 – 16.1, 187.3 –
228.9)
333 – 407
(3.3 – 4.1, 3.4 – 4.2, 48.3 – 59.0)
HA-164
< SYMPTOM DIAGNOSIS >
[R9M (FOR RUSSIA)]
REFRIGERATION SYSTEM SYMPTOMS
SYMPTOM DIAGNOSIS
REFRIGERATION SYSTEM SYMPTOMS
Trouble Diagnosis For Unusual Pressure
INFOID:0000000011006167
Diagnose using a manifold gauge whenever system’s high and/or low side pressure(s) is/are unusual. The
marker above the gauge scale in the following tables indicates the standard (usual) pressure range. Refer to
above table (Ambient air temperature-to-operating pressure table) since the standard (usual) pressure, how-
ever, differs from vehicle to vehicle.
Symptom Table
INFOID:0000000011006168
Gauge indication
Refrigerant cycle
Probable cause
Corrective action
Both high- and low-pressure sides
are too high.
The pressure returns to nor-
mal soon after sprinkling wa-
ter on condenser.
Overfilled refrigerant.
Collect all refrigerant, evacuate
refrigerant cycle again, and
then refill it with the specified
amount of refrigerant.
Air flow to condenser is insuf-
ficient.
Insufficient condenser cooling
performance.
• Poor fan rotation of radiator
and condenser.
• Improper installation of air
guide.
• Clogged or dirty condenser
fins.
• Repair or replace malfunc-
tioning parts.
• Clean and repair condenser
fins.
When compressor is stopped,
a high-pressure reading
quickly drops by approximate-
ly 196 kPa (1.96 bar, 2 kg/
cm
2
, 28 psi). It then gradually
decreases.
Air mixed in refrigerant cycle.
Collect all refrigerant, evacuate
refrigerant cycle again, and
then refill it with the specified
amount of refrigerant.
• Low-pressure pipe is cooler
than the outlet of evapora-
tor.
• Low-pressure pipe is frost-
ed.
Expansion valve opened too
much (excessive flow of refrig-
erant).
Replace expansion valve.
High-pressure side is excessively
high and low-pressure side is too
low.
High-pressure pipe and upper
side of condenser become
hot, however, liquid tank does
not become so hot.
Clogged or crushed high-pres-
sure pipe located between
compressor and condenser.
Repair or replace the malfunc-
tioning parts.
High-pressure side is too low and
low-pressure side is too high.
• The readings of both sides
become equal soon after
compressor operation
stops.
• There is no temperature dif-
ference between high- and
low-pressure sides.
Malfunction in compressor sys-
tem (insufficient compressor
pressure operation).
• Damage or breakage of
valve.
• Malfunctioning gaskets.
Replace compressor.
AC359A
AC360A
AC356A
REFRIGERATION SYSTEM SYMPTOMS
HA-165
< SYMPTOM DIAGNOSIS >
[R9M (FOR RUSSIA)]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
Both high- and low-pressure sides
are too low.
• The area around evapora-
tor outlet does not become
cold.
• The area around evapora-
tor inlet becomes frosted.
Clogged expansion valve.
• Breakage of temperature
sensor.
• Clogging by foreign material.
Eliminate foreign material from
expansion valve, or replace it.
• There is a temperature dif-
ference between the areas
around outlet and inlet
pipes of liquid tank.
• Liquid tank becomes frost-
ed.
Malfunction in inner liquid tank
(clogged strainer).
Replace condenser.
Evaporator becomes frosted.
Clogged or crushed low-pres-
sure pipe.
Repair or replace malfunction-
ing parts.
Malfunction in intake air tem-
perature sensor.
Check intake sensor system.
Refer to
(AUTOMATIC AIR
CONDITIONING),
AL AIR CONDITIONING).
There is a small temperature
difference between the high
and low pressure pipes for re-
frigerant cycle.
• Shortage of refrigerant.
• Leakage of refrigerant.
• Check for leakage.
• Collect all refrigerant, evacu-
ate refrigerant cycle again,
and then refill it with the spec-
ified amount of refrigerant.
Low-pressure side sometimes be-
comes negative.
• Sometimes the area
around evaporator outlet
does not become cold.
• Sometimes the area
around evaporator inlet is
frosted.
• Icing caused by the mixing of
water in cooler cycle.
• Deteriorated dryer in liquid
tank.
• Collect all refrigerant.
• Evacuate refrigerant cycle
completely, and then refill it
with the specified amount of
refrigerant. At this time, al-
ways replace condenser.
Hunting in high-pressure side.
There is no temperature dif-
ference between high- and
low-pressure sides.
Malfunctioning variable valve
in compressor.
• Replace compressor.
• Check ECV system. Refer to
HAC-113, "Diagnosis Proce-
dure"
(AUTOMATIC AIR
CONDITIONING),
(MANUAL AIR CONDITION-
ING).
Gauge indication
Refrigerant cycle
Probable cause
Corrective action
AC353A
AC354A
HA-166
< SYMPTOM DIAGNOSIS >
[R9M (FOR RUSSIA)]
NOISE
NOISE
Symptom Table
INFOID:0000000011006169
Symptom
Noise source
Probable cause
Corrective action
Unusual noise from compressor
when A/C is ON.
Inside of compressor
Wear, breakage, or clogging of foreign
material in inner parts.
Check compressor oil. Re-
fer to
.
Magnet clutch
Contact of clutch disc with pulley.
Check clearance between
clutch disc and pulley. Refer
to
.
Compressor body
Loosened compressor mounting bolts.
Check bolts for tightness.
Refer to
Unusual noise from cooler piping.
Cooler piping (pipe and
flexible hose)
Improper installation of clip and brack-
et.
Check the installation condi-
tion of the cooler piping. Re-
fer to
Unusual noise from expansion
valve when A/C is ON.
Expansion valve
Shortage of refrigerant.
• Check for leakage.
• Collect all refrigerant,
evacuate refrigerant cycle
again, and then refill it
with the specified amount
of refrigerant.
Wear, breakage, or clogging of foreign
material in inner parts.
Eliminate foreign material
from expansion valve, or re-
place it.
Unusual noise from belt.
—
Loosened belt
Check belt tension. Refer to
Internal compressor parts get locked
Replace compressor.