Nissan Titan. Manual — part 476
POWER WINDOW MAIN SWITCH
PWC-77
< ECU DIAGNOSIS INFORMATION >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
Terminal No.
(Wire color)
Description
Condition
Voltage [V]
(Approx.)
+
–
Signal name
Input/
Output
1
(W/R)
Ground
Battery power supply
Input
—
Battery voltage
5
(BR)
Ground
Encoder power supply
Output
When ignition switch ON or
power window timer operates
10
6
(L)
Ground
Door key cylinder switch
LH LOCK signal
Input
Key position
(Neutral
→ Locked)
5
→ 0
7
(R)
Ground
Door key cylinder switch
LH
UNLOCK signal
Input
Key position
(Neutral
→ Unlocked)
5
→ 0
8
(G/R)
11
Front door power window
motor LH UP signal
Output
When front LH switch in
power window main switch is
operated UP.
Battery voltage
9
(O)
3
Encoder pulse signal 2
Input
When power window motor op-
erates.
10
(W/L)
Ground
RAP signal
Input
IGN SW ON
Battery voltage
Within 45 second after ignition
switch is turned to OFF.
Battery voltage
When front LH or RH door is
opened during retained power
operation.
0
11
(G/W)
8
Front door power window
motor LH DOWN signal
Output
When front LH switch in
power window main switch is
operated DOWN.
Battery voltage
12
(LG/W)
Ground
Power window serial link
Input/
Output
IGN SW ON or power window
timer operating.
13
(G/Y)
3
Encoder pulse signal 1
Input
When power window motor op-
erates.
14
(W/B)
Ground
Encoder ground
—
—
0
15
(B)
Ground
Ground
—
—
0
JMKIA0070GB
JPMIA0013GB
JMKIA0070GB
PWC-78
< ECU DIAGNOSIS INFORMATION >
POWER WINDOW MAIN SWITCH
Fail Safe
INFOID:0000000009879018
FAIL-SAFE CONTROL
Switches to fail-safe control when malfunction is detected in encoder signal that detects up/down speed and
direction of door glass. Switches to fail-safe control when error beyond regulation value is detected between
the fully closed position and the actual position of the glass.
It changes to condition before initialization and the following functions do not operate when switched to fail-
safe control.
• Auto-up operation
• Anti-pinch function
• Retained power function
Perform initial operation to recover when switched to fail-safe mode. However, it switches back to fail-safe
control when malfunction is found in power window switch or in motor.
Error
Error condition
Pulse sensor malfunction
When only one side of pulse signal is being detected for more than the specified value.
Both pulse sensors mal-
function
When both pulse signals have not been detected for more than the specified value during glass open/
close operation.
Pulse direction malfunction
When the pulse signal that is detected during glass open/close operation detects the opposite condition
of power window motor operating direction.
Glass recognition position
malfunction 1
When it detects the error between glass fully closed position in power window switch memory and actual
fully closed position during glass open/close operation is more than the specified value.
Glass recognition position
malfunction 2
When it detects pulse count more than the value of glass full stroke during glass open/close operation.
Malfunction of not yet up-
dated closed position of
glass
When glass open/close operation is continuously performed without fully closing more than the specified
value (approximately 10 strokes).
FRONT POWER WINDOW SWITCH
PWC-79
< ECU DIAGNOSIS INFORMATION >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
FRONT POWER WINDOW SWITCH
Reference Value
INFOID:0000000009879019
TERMINAL LAYOUT
PHYSICAL VALUES
POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH
LIIA2454E
Terminal No.
(Wire color)
Description
Condition
Voltage [V]
(Approx.)
+
–
Signal name
Input/
Output
3
(W/B)
Ground
Encoder ground
—
—
0
4
(G/R)
Ground
Encoder power supply
Output
When ignition switch ON or
power window timer operates
10
8
(L)
9
Power window motor
UP signal
Output
When power window motor is
UP at operated.
Battery voltage
9
(G)
8
Power window motor
DOWN signal
Output
When power window motor is
DOWN at operated.
Battery voltage
10
(W/R)
Ground
Battery power supply
Input
—
Battery voltage
11
(B)
Ground
Ground
—
—
0
12
(G/Y)
3
Encoder pulse signal 1
Input
When power window motor op-
erates.
JMKIA0070GB
PWC-80
< ECU DIAGNOSIS INFORMATION >
FRONT POWER WINDOW SWITCH
Fail Safe
INFOID:0000000009879020
FAIL-SAFE CONTROL
Switches to fail-safe control when malfunction is detected in encoder signal that detects up/down speed and
direction of door glass. Switches to fail-safe control when error beyond regulation value is detected between
the fully closed position and the actual position of the glass.
It changes to condition before initialization and the following functions do not operate when switched to fail-
safe control.
• Auto-up operation
• Anti-pinch function
• Retained power function
Perform initial operation to recover when switched to fail-safe mode. However, it switches back to fail-safe
control when malfunction is found in power window switch or in motor.
15
(G/W)
3
Encoder pulse signal 2
Input
When power window motor op-
erates.
16
(LG/W)
Ground
Power window serial link
Input/
Output
IGN SW ON or power window
timer operating.
Terminal No.
(Wire color)
Description
Condition
Voltage [V]
(Approx.)
+
–
Signal name
Input/
Output
JMKIA0070GB
JPMIA0013GB
Error
Error condition
Pulse sensor malfunction
When only one side of pulse signal is being detected for more than the specified value.
Both pulse sensors mal-
function
When both pulse signals have not been detected for more than the specified value during glass open/
close operation.
Pulse direction malfunction
When the pulse signal that is detected during glass open/close operation detects the opposite condition
of power window motor operating direction.
Glass recognition position
malfunction 1
When it detects the error between glass fully closed position in power window switch memory and actual
fully closed position during glass open/close operation is more than the specified value.
Glass recognition position
malfunction 2
When it detects pulse count more than the value of glass full stroke during glass open/close operation.
Malfunction of not yet up-
dated closed position of
glass
When glass open/close operation is continuously performed without fully closing more than the specified
value (approximately 10 strokes).