Nissan Pathfinder (2011 year). Manual — part 456

AIR CONDITIONER CONTROL

HAC-111

< SYMPTOM DIAGNOSIS >

[AUTOMATIC AIR CONDITIONER]

C

D

E

F

G

H

J

K

L

M

A

B

HAC

N

O

P

SYMPTOM DIAGNOSIS

AIR CONDITIONER CONTROL

Symptom Matrix Chart

INFOID:0000000006243682

SYMPTOM TABLE

Symptom

Reference Page

A/C system does not come on.

Go to Trouble Diagnosis Procedure for A/C System.

HAC-90

A/C system display is malfunctioning.

Go to AV System.

AV-163

,

AV-64

A/C system cannot be controlled.

Go to Self-diagnosis Function.

HAC-24

Air outlet does not change.

Go to Trouble Diagnosis Procedure for Mode Door Motor.

HAC-27

Mode door motor is malfunctioning.

Discharge air temperature does not change.

Go to Trouble Diagnosis Procedure for Air Mix Door Motor.

HAC-32

,

HAC-34

Air mix door motor is malfunctioning.

Intake door does not change.

Go to Trouble Diagnosis Procedure for Intake Door Motor.

HAC-39

Intake door motor is malfunctioning.

Front blower motor operation is malfunction-
ing.

Go to Trouble Diagnosis Procedure for Front Blower Motor.

HAC-42

Rear blower motor operation is malfunction-
ing.

Go to Trouble Diagnosis Procedure for Rear Blower Motor.

HAC-48

Rear discharge air temperature and/or air
outlet does not change.

Go to Trouble Diagnosis Procedure for Rear Air Control system.

HAC-57

Magnet clutch does not engage.

Go to Trouble Diagnosis Procedure for Magnet Clutch.

HAC-69

Insufficient cooling

Go to Trouble Diagnosis Procedure for Insufficient Cooling.

HAC-112

Insufficient heating

Go to Trouble Diagnosis Procedure for Insufficient Heating.

HAC-120

Noise

Go to Trouble Diagnosis Procedure for Noise.

HAC-122

Self-diagnosis cannot be performed.

Go to Trouble Diagnosis Procedure for Self-diagnosis.

HAC-91

Memory function does not operate.

Go to Trouble Diagnosis Procedure for Memory Function.

HAC-124

2011 Pathfinder

HAC-112

< SYMPTOM DIAGNOSIS >

[AUTOMATIC AIR CONDITIONER]

INSUFFICIENT COOLING

INSUFFICIENT COOLING

Component Function Check

INFOID:0000000006243683

SYMPTOM: Insufficient cooling

INSPECTION FLOW

1.

CONFIRM SYMPTOM BY PERFORMING OPERATIONAL CHECK - TEMPERATURE DECREASE

1. Press the AUTO switch.

2. Turn temperature control dial (driver) counterclockwise until 18

°

C (60

°

F) is displayed.

3. Check for cold air at discharge air outlets.
Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK FOR ANY SYMPTOMS

Perform a complete operational check for any symptoms. Refer to

HAC-5, "Operational Check (Front)"

or

HAC-6, "Operational Check (Rear)"

.

Does another symptom exist?

YES

>> Refer to

HAC-111, "Symptom Matrix Chart"

.

NO

>> System OK.

3.

CHECK FOR SERVICE BULLETINS

Check for any service bulletins.

>> GO TO 4.

4.

PERFORM SELF-DIAGNOSIS

Perform self-diagnosis Refer to

HAC-24, "A/C Auto Amp. Self-Diagnosis"

.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Refer to

HAC-25, "A/C System Self-Diagnosis Code Chart"

.

5.

CHECK DRIVE BELTS

Check compressor belt tension. Refer to

EM-14, "Checking Drive Belts"

(VQ40DE) or

EM-153, "Checking

Drive Belts"

(VK56DE).

Is the inspection result normal?

OK

>> GO TO 6.

NG

>> Adjust or replace compressor belt. Refer to

EM-14, "Adjustment"

,

EM-14, "Removal and Installa-

tion"

(VQ40DE) or

EM-153, "Adjustment"

,

EM-153, "Removal and Installation"

(VK56DE).

6.

CHECK AIR MIX DOOR OPERATION

Check and verify air mix door mechanism for smooth operation. Refer to

HAC-31, "Air Mix Door Motor (Driver)

Component Function Check"

or

HAC-34, "Air Mix Door Motor (Passenger) Component Function Check"

.

Does air mix door operate correctly?

YES

>> GO TO 7.

NO

>> Check air mix door motor circuit. Refer to

HAC-32, "Air Mix Door Motor (Driver) Diagnosis Proce-

dure"

or

HAC-34, "Air Mix Door Motor (Passenger) Diagnosis Procedure"

.

7.

CHECK COOLING FAN MOTOR OPERATION

Check and verify cooling fan motor for smooth operation.
Does cooling fan motor operate correctly?

YES

>> GO TO 8.

NO

>> Check cooling fan motor.

8.

CHECK WATER VALVE OPERATION (VK56DE ONLY)

Check and verify water valve for smooth operation. Refer to

HAC-74, "Water Valve Description (VK56DE)"

.

2011 Pathfinder

INSUFFICIENT COOLING

HAC-113

< SYMPTOM DIAGNOSIS >

[AUTOMATIC AIR CONDITIONER]

C

D

E

F

G

H

J

K

L

M

A

B

HAC

N

O

P

Does water valve operate correctly?

YES

>> GO TO 9.

NO

>> Check water valve circuit. Refer to

HAC-74, "Water Valve Diagnosis Procedure (VK56DE)"

.

9.

CHECK RECOVERY/RECYCLING EQUIPMENT BEFORE USAGE

Check recovery/recycling equipment before connecting to vehicle. Verify there is no pressure in the recovery/

recycling equipment by checking the gauges. If pressure exists, recover refrigerant from equipment lines.

>> GO TO 10.

10.

CHECK REFRIGERANT PURITY

1. Connect recovery/recycling equipment to vehicle.

2. Confirm refrigerant purity in supply tank using recovery/recycling and refrigerant identifier.
Is the inspection result normal?

YES

>> GO TO 11.

NO

>> Check contaminated refrigerant. Refer to

HAC-126, "Working with HFC-134a (R-134a)"

.

11.

CHECK FOR EVAPORATOR FREEZE UP

Start engine and run A/C. Check for evaporator freeze up.
Does evaporator freeze up?

YES

>> Perform diagnostic work flow. Refer to

HAC-113, "Diagnostic Work Flow"

.

NO

>> GO TO 12.

12.

CHECK REFRIGERANT PRESSURE

Check refrigerant pressure with manifold gauge connected. Refer to

HAC-115, "Performance Chart"

.

Is the inspection result normal?

YES

>> GO TO 13.

NO

>> Perform diagnostic work flow. Refer to

HAC-113, "Diagnostic Work Flow"

.

13.

CHECK AIR DUCTS

Check ducts for air leaks.
Is the inspection result normal?

YES

>> System OK.

NO

>> Repair air leaks.

Diagnostic Work Flow

INFOID:0000000006243684

2011 Pathfinder

INSUFFICIENT COOLING

HAC-115

< SYMPTOM DIAGNOSIS >

[AUTOMATIC AIR CONDITIONER]

C

D

E

F

G

H

J

K

L

M

A

B

HAC

N

O

P

Performance Chart

INFOID:0000000006243685

TEST CONDITION

Testing must be performed as follows:

*1

VTL-12, "Removal and Installation"

*2

HAC-42, "Front Blower Motor Diag-
nosis Procedure"

*3

HA-40, "Removal and Installation for
Compressor Clutch"

*4

EM-14, "Checking Drive Belts"

(VQ40DE) or

EM-153, "Checking

Drive Belts"

(VK56DE)

*5

HA-38, "Removal and Installation for
Compressor"

AWIIA1000GB

2011 Pathfinder

HAC-116

< SYMPTOM DIAGNOSIS >

[AUTOMATIC AIR CONDITIONER]

INSUFFICIENT COOLING

TEST READING

Recirculating-to-discharge Air Temperature Table

Ambient Air Temperature-to-operating Pressure Table

Trouble Diagnoses for Abnormal Pressure

INFOID:0000000006243686

Whenever system

s high and/or low side pressure is abnormal, diagnose using a manifold gauge. The marker

above the gauge scale in the following tables indicates the standard (usual) pressure range. Since the stan-

Vehicle location

Indoors or in the shade (in a well-ventilated place)

Doors

Closed

Door window

Open

Hood

Open

TEMP.

Max. COLD

Mode switch

(Ventilation) set

Recirculation (REC) switch

(Recirculation) set

Blower speed

Max. speed set

Engine speed

Idle speed

Operate the air conditioning system for 10 minutes before taking measurements.

Inside air (Recirculating air) at blower assembly inlet

Discharge air temperature at center ventilator

°

C (

°

F)

Relative humidity

%

Air temperature

°

C (

°

F)

50 - 60

20 (68)

5.3 - 6.5 (42 - 44)

25 (77)

9.7 - 11.5 (49 - 53)

30 (86)

13.8 - 16.3 (57 - 61)

35 (95)

18.0 - 21.2 (64 - 70)

40 (104)

22.2 - 25.7 (72 - 78)

60 - 70

20 (68)

6.5 - 7.7 (44 - 46)

25 (77)

11.5 - 13.3 (53 - 56)

30 (86)

16.3 - 18.8 (61 - 66)

35 (95)

21.2 - 24.0 (70 - 75)

40 (104)

25.7 - 29.2 (78 - 85)

Ambient air

High-pressure (Discharge side)

kPa (kg/cm

2

, psi)

Low-pressure (Suction side)

kPa (kg/cm

2

, psi)

Relative humidity

%

Air temperature

°

C (

°

F)

50 - 70

20 (68)

680 - 840

(6.94 - 8.57, 98.6 - 121.8)

160 - 198

(1.63 - 2.02, 23.2 - 28.7)

25 (77)

800 - 985

(8.16 - 10.05, 116.0 - 142.8)

198 - 245

(2.02 - 2.50, 28.7 - 35.5)

30 (86)

940 - 1,150

(9.59 - 11.73, 136.3 - 166.8)

225 - 278

(2.30 - 2.84, 32.6 - 40.3)

35 (95)

1,160 - 1,410

(11.83 - 14.38, 168.2 - 204.5)

273 - 335

(2.78 - 3.42, 39.6 - 48.6)

40 (104)

1,325 - 1,620

(13.52 - 16.52, 192.1 - 234.9)

325 - 398

(3.32 - 4.06, 47.1 - 57.7)

2011 Pathfinder

INSUFFICIENT COOLING

HAC-117

< SYMPTOM DIAGNOSIS >

[AUTOMATIC AIR CONDITIONER]

C

D

E

F

G

H

J

K

L

M

A

B

HAC

N

O

P

dard (usual) pressure, however, differs from vehicle to vehicle, refer to above table (Ambient air temperature-

to-operating pressure table).

Both High- and Low-pressure Sides are Too High

High-pressure Side is Too High and Low-pressure Side is Too Low

High-pressure Side is Too Low and Low-pressure Side is Too High

Gauge indication

Refrigerant cycle

Probable cause

Corrective action

Both high- and low-pressure sides
are too high.

Pressure is reduced soon af-
ter water is splashed on con-
denser.

Excessive refrigerant charge in
refrigeration cycle

Reduce refrigerant until speci-
fied pressure is obtained.

Air suction by cooling fan is in-
sufficient.

Insufficient condenser cooling
performance

1.

Condenser fins are
clogged.

2.

Improper fan rotation of
cooling fan

• Clean condenser.
• Check and repair cooling fan

if necessary.

• Low-pressure pipe is not

cold.

• When compressor is

stopped high-pressure val-
ue quickly drops by approx-
imately 196 kPa (2 kg/cm

2

,

28 psi). It then decreases
gradually thereafter.

Poor heat exchange in con-
denser
(After compressor operation
stops, high-pressure decreas-
es too slowly.)

Air in refrigeration cycle

Evacuate and recharge system.

Engine tends to overheat.

Engine cooling systems mal-
function.

Check and repair engine cool-
ing system.

• An area of the low-pressure

pipe is colder than areas
near the evaporator outlet.

• Plates are sometimes cov-

ered with frost.

• Excessive liquid refrigerant

on low-pressure side

• Excessive refrigerant dis-

charge flow

• Expansion valve is open a lit-

tle compared with the speci-
fication.

Improper expansion valve ad-
justment

Replace expansion valve.

AC359A

Gauge indication

Refrigerant cycle

Probable cause

Corrective action

High-pressure side is too high and
low-pressure side is too low.

Upper side of condenser and
high-pressure side are hot,
however, liquid tank is not so
hot.

High-pressure tube or parts lo-
cated between compressor
and condenser are clogged or
crushed.

• Check and repair or replace

malfunctioning parts.

• Check oil for contamination.

AC360A

2011 Pathfinder

HAC-118

< SYMPTOM DIAGNOSIS >

[AUTOMATIC AIR CONDITIONER]

INSUFFICIENT COOLING

Both High- and Low-pressure Sides are Too Low

Low-pressure Side Sometimes Becomes Negative

Gauge indication

Refrigerant cycle

Probable cause

Corrective action

High-pressure side is too low and
low-pressure side is too high.

High- and low-pressure sides
become equal soon after com-
pressor operation stops.

Compressor pressure opera-
tion is improper.

Damaged inside compressor
packings.

Replace compressor.

No temperature difference be-
tween high- and low-pressure
sides.

Compressor pressure opera-
tion is improper.

Damaged inside compressor
packings.

Replace compressor.

AC356A

Gauge indication

Refrigerant cycle

Probable cause

Corrective action

Both high- and low-pressure sides
are too low.

• There is a big temperature

difference between liquid
tank outlet and inlet. Outlet
temperature is extremely
low.

• Liquid tank inlet and expan-

sion valve are frosted.

Liquid tank inside is slightly
clogged.

• Replace liquid tank.
• Check oil for contamination.

• Temperature of expansion

valve inlet is extremely low
as compared with areas
near liquid tank.

• Expansion valve inlet may

be frosted.

• Temperature difference oc-

curs somewhere in high-
pressure side.

High-pressure pipe located be-
tween liquid tank and expan-
sion valve is clogged.

• Check and repair malfunc-

tioning parts.

• Check oil for contamination.

Expansion valve and liquid
tank are warm or only cool
when touched.

Low refrigerant charge.

Leaking fittings or compo-
nents.

Check refrigerant system for
leaks. Refer to

HA-29, "Check-

ing System for Leaks Using the
Fluorescent Dye Leak Detec-
tor"

or

HA-31, "Electronic Re-

frigerant Leak Detector"

.

There is a big temperature dif-
ference between expansion
valve inlet and outlet while the
valve itself is frosted.

Expansion valve closes a little
compared with the specifica-
tion.

1.

Improper expansion
valve adjustment.

2.

Malfunctioning expansion
valve.

3.

Outlet and inlet may be
clogged.

• Remove foreign particles by

using compressed air.

• Check oil for contamination.

An area of the low-pressure
pipe is colder than areas near
the evaporator outlet.

Low-pressure pipe is clogged
or crushed.

• Check and repair malfunc-

tioning parts.

• Check oil for contamination.

Air flow volume is too low.

Evaporator is frozen.

• Check intake sensor circuit.

Refer to

HAC-87, "Intake

Sensor Diagnosis Proce-
dure"

.

• Repair evaporator fins.
• Replace evaporator.
• Refer to

HAC-42, "Front

Blower Motor Component
Function Check"

.

AC353A

2011 Pathfinder