Nissan Xterra. Manual — part 153
BRM-32
< REMOVAL AND INSTALLATION >
BODY ALIGNMENT
MEASUREMENT
LIIA2075E
BODY ALIGNMENT
BRM-33
< REMOVAL AND INSTALLATION >
C
D
E
F
G
H
I
J
L
M
A
B
BRM
N
O
P
MEASUREMENT POINTS
Body Mounting
INFOID:0000000009484354
• When removing, be sure to replace bolts and nuts (sealant applied bolts or self-lock nuts are used for all
mounting).
• Unless otherwise noted, the bushings and insulators have paint marks that are to be installed facing out-
ward.
LIIA2076E
BRM-34
< REMOVAL AND INSTALLATION >
BODY ALIGNMENT
1.
Gold washer
2.
Upper bushing
3.
Lower bushing
4.
Black washer
5.
Lower bushing without paint mark
6.
Upper bushing without paint mark
7.
Body mount insulator
8.
Body washer
LIIA2112E
REPAIRING HIGH STRENGTH STEEL
BRM-35
< REMOVAL AND INSTALLATION >
C
D
E
F
G
H
I
J
L
M
A
B
BRM
N
O
P
REPAIRING HIGH STRENGTH STEEL
Precaution in Repairing High Strength Steel
INFOID:0000000009484355
High strength steel is used for body panels in order to reduce vehicle weight.
Accordingly, precautions in repairing automotive bodies made of high strength steel are described below:
High strength steel (hss) used in NISSAN vehicles
SP130 is the most commonly used HSS.
SP150 HSS is used only on parts that require much more strength.
Read the following precautions when repairing HSS:
1. Additional points to consider
• The repair of reinforcements (such as side members) by heat-
ing is not recommended since it may weaken the component.
When heating is unavoidable, do not heat HSS parts above
550
°C (1,022°F).
Verify heating temperature with a thermometer.
(Crayon-type and other similar type thermometer are appropri-
ate.)
• When straightening body panels, use caution in pulling any
HSS panel. Because HSS is very strong, pulling may cause
deformation in adjacent portions of the body. In this case,
increase the number of measuring points, and carefully pull
the HSS panel.
• When cutting HSS panels, avoid gas (torch) cutting if possible.
Instead, use a saw to avoid weakening surrounding areas due
to heat. If gas (torch) cutting is unavoidable, allow a minimum
margin of 50 mm (1.97in).
Tensile strength
NISSAN/INFINITI designation
Major applicable parts
373 N/mm
2
(38 kg/mm
2
,54 klb/sq in)
SP130
• Upper inner front pillar
• Front pillar hinge brace
• Outer front pillar reinforcement
• Other reinforcements
785-981 N/mm
2
(80-100 kg/mm
2
114-142 klb/sq in)
SP150
• Outer sill reinforcement
• Main back pillar
PIIA0115E
PIIA0116E
PIIA0117E