Qashqai J11. Door & Lock — part 26

BACK DOOR OPENER ACTUATOR

DLK-417

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

DTC/CIRCUIT DIAGNOSIS

BACK DOOR OPENER ACTUATOR

Component Function Check

INFOID:0000000010499797

1.

CHECK FUNCTION

1.

Select “INTELLIGENT KEY” of “BCM” using CONSULT.

2.

Select “TRUNK/BACK DOOR” in “ACTIVE TEST” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Back door opener actuator is OK.

NO

>> Refer to

DLK-417, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000010499798

1.

CHECK BACK DOOR OPENER ACTUATOR INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect back door lock assembly connector.

3.

Check voltage between back door lock assembly harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK BACK DOOR OPENER ACTUATOR CIRCUIT

1.

Disconnect BCM connector.

2.

Check continuity between BCM harness connector and back door lock assembly harness connector.

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to

BCS-135, "Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK BACK DOOR OPENER ACTUATOR GROUND CIRCUIT

Check continuity between back door lock assembly harness connector and ground.

Monitor item

Status

TRUNK/BACK DOOR

OPEN

Back door

OPEN

(+)

(–)

Condition

Voltage

Back door lock assembly

Connector

Terminal

B2

1

Ground

Back door
opener switch

ON

9 - 16 V

BCM

Back door lock assembly

Continuity

Connector

Terminal

Connector

Terminal

B3

121

B2

1

Existed

BCM

Ground

Continuity

Connector

Terminal

B3

121

Not existed

DLK-418

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

BACK DOOR OPENER ACTUATOR

Is the inspection normal?

YES

>> Replace back door lock assembly.

NO

>> Repair or replace harness.

Back door lock assembly

Ground

Continuity

Connector

Terminal

B2

2

Existed

BACK DOOR OPENER SWITCH

DLK-419

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

BACK DOOR OPENER SWITCH

Component Function Check

INFOID:0000000010499799

1.

CHECK FUNCTION

1.

Select “TRUNK” of “BCM” using CONSULT.

2.

Select “BACK DOOR OPENER SW” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Back door opener switch is OK.

NO

>> Refer to

DLK-419, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000010499800

1.

CHECK BACK DOOR OPENER SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect back door opener switch assembly connector.

3.

Check signal between back door opener switch assembly harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK BACK DOOR OPENER SWITCH CIRCUIT

1.

Disconnect BCM connector.

2.

Check continuity between BCM harness connector and back door opener switch assembly harness con-
nector.

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to

BCS-135, "Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK BACK DOOR OPENER SWITCH GROUND CIRCUIT

Check continuity between back door opener switch assembly harness connector and ground.

Monitor item

Condition

Status

BACK DOOR OPENER SW

Back door opener switch

Pressed

ON

Released

OFF

(+)

(–)

Voltage

Back door opener switch assembly

Connector

Terminal

D94

1

Ground

9 - 16 V

BCM

Back door opener switch assembly

Continuity

Connector

Terminal

Connector

Terminal

B4

16

D94

1

Existed

BCM

Ground

Continuity

Connector

Terminal

B4

16

Not existed

DLK-420

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

BACK DOOR OPENER SWITCH

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK BACK DOOR OPENER SWITCH

Refer to

DLK-420, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace back door opener switch assembly.

5.

CHECK INTERMITTENT INCIDENT

Refer to

GI-44, "Intermittent Incident"

.

>> INSPECTION END

Component Inspection

INFOID:0000000010499801

1.

CHECK BACK DOOR OPENER SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect back door opener switch assembly connector.

3.

Check continuity between back door opener switch assembly terminals.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace back door opener switch assembly.

Back door opener switch assembly

Ground

Continuity

Connector

Terminal

D94

4

Existed

Back door opener switch assembly

Condition

Continuity

Terminal

1

4

Back door opener
switch

Pressed

Existed

Released

Not existed

DOOR LOCK ACTUATOR

DLK-421

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

DOOR LOCK ACTUATOR

DRIVER SIDE

DRIVER SIDE : Component Function Check

INFOID:0000000010499802

1.

CHECK FUNCTION

1.

Select “DOOR LOCK” of “BCM” using CONSULT.

2.

Select “DOOR LOCK” in “ACTIVE TEST” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Door lock actuator is OK.

NO

>> Refer to

DLK-421, "DRIVER SIDE : Diagnosis Procedure"

.

DRIVER SIDE : Diagnosis Procedure

INFOID:0000000010499803

1.

CHECK DOOR LOCK ACTUATOR INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect front door lock assembly (driver side) connector.

3.

Check voltage between front door lock assembly (driver side) harness connector and ground.

Is the inspection result normal?

YES

>> Replace front door lock assembly (driver side).

NO

>> GO TO 2.

2.

CHECK DOOR LOCK ACTUATOR CIRCUIT

1.

Disconnect BCM connector and all door lock assembly connector.

2.

Check continuity between BCM harness connector and front door lock assembly (driver side) harness
connector.

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness.

Monitor item

Status

DOOR LOCK

ALL LOCK

Door lock actuators

LOCK

ALL UNLOCK

UNLOCK

(+)

(–)

Condition

Voltage

Front door lock assembly

(driver side)

Connector

Terminal

D26

2

Ground

Door lock and unlock switch

Unlock

9 – 16 V

3

Lock

BCM

Front door lock assembly (driver side)

Continuity

Connector

Terminal

Connector

Terminal

M68

141

D26

3

Existed

148

2

BCM

Ground

Continuity

Connector

Terminal

M68

141

Not existed

148

DLK-422

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

DOOR LOCK ACTUATOR

3.

CHECK BCM OUTPUT SIGNAL

1.

Connect BCM connector.

2.

Check voltage between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Check for internal short of each door lock actuator.

NO

>> Replace BCM. Refer to

BCS-135, "Removal and Installation"

.

PASSENGER SIDE

PASSENGER SIDE : Component Function Check

INFOID:0000000010499804

1.

CHECK FUNCTION

1.

Select “DOOR LOCK” of “BCM” using CONSULT.

2.

Select “DOOR LOCK” in “ACTIVE TEST” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Door lock actuator is OK.

NO

>> Refer to

DLK-421, "DRIVER SIDE : Diagnosis Procedure"

.

PASSENGER SIDE : Diagnosis Procedure

INFOID:0000000010499805

1.

CHECK DOOR LOCK ACTUATOR INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect front door lock assembly (passenger side) connector.

3.

Check voltage between front door lock assembly (passenger side) harness connector and ground.

Is the inspection result normal?

YES

>> Replace front door lock assembly (passenger side).

NO

>> GO TO 2.

2.

CHECK DOOR LOCK ACTUATOR CIRCUIT

1.

Disconnect BCM connector and all door lock assembly connector.

2.

Check continuity between BCM harness connector and front door lock assembly (passenger side) har-
ness connector.

(+)

(–)

Condition

Voltage

BCM

Connector

Terminal

M68

141

Ground

Door lock and unlock switch

Lock

9 – 16 V

148

Unlock

Monitor item

Status

DOOR LOCK

ALL LOCK

Door lock actuators

LOCK

ALL UNLOCK

UNLOCK

(+)

(–)

Condition

Voltage

Front door lock assembly

(passenger side)

Connector

Terminal

D2

2

Ground

Door lock and unlock switch

Unlock

9 – 16 V

3

Lock

DOOR LOCK ACTUATOR

DLK-423

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness.

3.

CHECK BCM OUTPUT SIGNAL

1.

Connect BCM connector.

2.

Check voltage between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Check for internal short of each door lock actuator.

NO

>> Replace BCM. Refer to

BCS-135, "Removal and Installation"

.

REAR LH

REAR LH : Component Function Check

INFOID:0000000010499806

1.

CHECK FUNCTION

1.

Select “DOOR LOCK” of “BCM” using CONSULT.

2.

Select “DOOR LOCK” in “ACTIVE TEST” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Door lock actuator is OK.

NO

>> Refer to

DLK-421, "DRIVER SIDE : Diagnosis Procedure"

.

REAR LH : Diagnosis Procedure

INFOID:0000000010499807

1.

CHECK DOOR LOCK ACTUATOR INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect rear door lock assembly LH connector.

3.

Check voltage between rear door lock assembly LH harness connector and ground.

BCM

Front door lock assembly (passenger side)

Continuity

Connector

Terminal

Connector

Terminal

M68

139

D2

2

Existed

141

3

BCM

Ground

Continuity

Connector

Terminal

M68

139

Not existed

141

(+)

(–)

Condition

Voltage

BCM

Connector

Terminal

M68

139

Ground

Door lock and unlock switch

Unlock

9 – 16 V

141

Lock

Monitor item

Status

DOOR LOCK

ALL LOCK

Door lock actuators

LOCK

ALL UNLOCK

UNLOCK

DLK-424

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

DOOR LOCK ACTUATOR

Is the inspection result normal?

YES

>> Replace rear door lock assembly LH.

NO

>> GO TO 2.

2.

CHECK DOOR LOCK ACTUATOR CIRCUIT

1.

Disconnect BCM connector and all door lock assembly connector.

2.

Check continuity between BCM harness connector and rear door lock assembly LH harness connector.

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness.

3.

CHECK BCM OUTPUT SIGNAL

1.

Connect BCM connector.

2.

Check voltage between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Check for internal short of each door lock actuator.

NO

>> Replace BCM. Refer to

BCS-135, "Removal and Installation"

.

REAR RH

REAR RH : Component Function Check

INFOID:0000000010499808

1.

CHECK FUNCTION

1.

Select “DOOR LOCK” of “BCM” using CONSULT.

2.

Select “DOOR LOCK” in “ACTIVE TEST” mode.

3.

Check that the function operates normally according to the following conditions.

(+)

(–)

Condition

Voltage

Rear door lock assembly LH

Connector

Terminal

D52

2

Ground

Door lock and unlock switch

Unlock

9 – 16 V

3

Lock

BCM

Rear door lock assembly LH

Continuity

Connector

Terminal

Connector

Terminal

B3

124

D52

2

Existed

125

3

BCM

Ground

Continuity

Connector

Terminal

B3

124

Not existed

125

(+)

(–)

Condition

Voltage

BCM

Connector

Terminal

B3

124

Ground

Door lock and unlock switch

Unlock

9 – 16 V

125

Lock

Monitor item

Status

DOOR LOCK

ALL LOCK

Door lock actuators

LOCK

ALL UNLOCK

UNLOCK

DOOR LOCK ACTUATOR

DLK-425

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

Is the inspection result normal?

YES

>> Door lock actuator is OK.

NO

>> Refer to

DLK-421, "DRIVER SIDE : Diagnosis Procedure"

.

REAR RH : Diagnosis Procedure

INFOID:0000000010499809

1.

CHECK DOOR LOCK ACTUATOR INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect rear door lock assembly RH connector.

3.

Check voltage between rear door lock assembly RH harness connector and ground.

Is the inspection result normal?

YES

>> Replace rear door lock assembly RH.

NO

>> GO TO 2.

2.

CHECK DOOR LOCK ACTUATOR CIRCUIT

1.

Disconnect BCM connector and all door lock assembly connector.

2.

Check continuity between BCM harness connector and rear door lock assembly RH harness connector.

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness.

3.

CHECK BCM OUTPUT SIGNAL

1.

Connect BCM connector.

2.

Check voltage between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Check for internal short of each door lock actuator.

NO

>> Replace BCM. Refer to

BCS-135, "Removal and Installation"

.

(+)

(–)

Condition

Voltage

Rear door lock assembly RH

Connector

Terminal

D65

2

Ground

Door lock and unlock switch

Unlock

9 – 16 V

3

Lock

BCM

Rear door lock assembly RH

Continuity

Connector

Terminal

Connector

Terminal

B3

124

D65

2

Existed

125

3

BCM

Ground

Continuity

Connector

Terminal

B3

124

Not existed

125

(+)

(–)

Condition

Voltage

BCM

Connector

Terminal

B3

124

Ground

Door lock and unlock switch

Unlock

9 – 16 V

125

Lock

DLK-426

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

DOOR LOCK AND UNLOCK SWITCH

DOOR LOCK AND UNLOCK SWITCH

DRIVER SIDE

DRIVER SIDE : Component Function Check

INFOID:0000000010499812

1.

CHECK FUNCTION

1.

Select “DOOR LOCK” of “BCM” using CONSULT.

2.

Select “CDL LOCK SW”, “CDL UNLOCK SW” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Door lock and unlock switch is OK.

NO

>> Refer to

DLK-426, "DRIVER SIDE : Diagnosis Procedure"

.

DRIVER SIDE : Diagnosis Procedure

INFOID:0000000010499813

1.

CHECK DOOR LOCK AND UNLOCK SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect power window main switch connector.

3.

Check signal between power window main switch harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK DOOR LOCK AND UNLOCK SWITCH CIRCUIT

1.

Disconnect BCM connector and front power window switch (passenger side) connector.

2.

Check continuity between BCM harness connector and power window main switch harness connector.

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to

BCS-135, "Removal and Installation"

.

NO

>> Repair or replace harness.

Monitor item

Condition

Status

CDL LOCK SW

Door lock and unlock switch

Lock

ON

Unlock

OFF

CDL UNLOCK SW

Lock

OFF

Unlock

ON

(+)

(–)

Voltage

Power window main switch

Connector

Terminal

D30

3

Ground

9 - 16 V

15

BCM

Power window main switch

Continuity

Connector

Terminal

Connector

Terminal

M70

50

D30

3

Existed

80

15

BCM

Ground

Continuity

Connector

Terminal

M70

50

Not existed

80

DOOR LOCK AND UNLOCK SWITCH

DLK-427

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

3.

CHECK INTERMITTENT INCIDENT

Refer to

GI-44, "Intermittent Incident"

.

Is the inspection result normal?

YES

>> Replace power window main switch. Refer to

PWC-68, "POWER WINDOW MAIN SWITCH :

Removal and Installation"

.

NO

>> INSPECTION END

PASSENGER SIDE

PASSENGER SIDE : Component Function Check

INFOID:0000000010499818

1.

CHECK FUNCTION

1.

Select “DOOR LOCK” of “BCM” using CONSULT.

2.

Select “CDL LOCK SW”, “CDL UNLOCK SW” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Door lock and unlock switch is OK.

NO

>> Refer to

DLK-427, "PASSENGER SIDE : Diagnosis Procedure"

.

PASSENGER SIDE : Diagnosis Procedure

INFOID:0000000010499819

1.

CHECK DOOR LOCK AND UNLOCK SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect front power window switch (passenger side) connector.

3.

Check signal between front power window switch (passenger side) harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK DOOR LOCK AND UNLOCK SWITCH CIRCUIT

1.

Disconnect BCM connector and power window main switch connector.

2.

Check continuity between BCM harness connector and front power window switch (passenger side) har-
ness connector.

3.

Check continuity between BCM harness connector and ground.

Monitor item

Condition

Status

CDL LOCK SW

Door lock and unlock switch

Lock

ON

Unlock

OFF

CDL UNLOCK SW

Lock

OFF

Unlock

ON

(+)

(–)

Voltage

Front power window switch (passenger side)

Connector

Terminal

D7

1

Ground

9 - 16 V

2

BCM

Front power window switch (passenger side)

Continuity

Connector

Terminal

Connector

Terminal

M70

50

D7

1

Existed

80

2

DLK-428

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

DOOR LOCK AND UNLOCK SWITCH

Is the inspection result normal?

YES

>> Replace BCM. Refer to

BCS-135, "Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK INTERMITTENT INCIDENT

Refer to

GI-44, "Intermittent Incident"

.

Is the inspection result normal?

YES

>> Replace front power window switch (passenger side). Refer to

PWC-68, "FRONT POWER WIN-

DOW SWITCH (PASSENGER SIDE) : Removal and Installation"

.

NO

>> INSPECTION END

BCM

Ground

Continuity

Connector

Terminal

M70

50

Not existed

80

DOOR LOCK STATUS INDICATOR

DLK-429

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

DOOR LOCK STATUS INDICATOR

Component Function Check

INFOID:0000000010499820

1.

CHECK FUNCTION

1.

Select “DOOR LOCK” of “BCM” using CONSULT.

2.

Select “DOOR LOCK IND” in “ACTIVE TEST” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Door lock status indicator is OK.

NO

>> Refer to

DLK-429, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000010499821

1.

CHECK DOOR LOCK STATUS INDICATOR INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect indicator unit connector.

3.

Check voltage between indicator unit harness connector and ground.

Is the inspection result normal?

YES

>> Replace indicator unit.

NO

>> GO TO 2.

2.

CHECK DOOR LOCK STATUS INDICATOR CIRCUIT

1.

Disconnect BCM connector.

2.

Check continuity between BCM harness connector and indicator unit harness connector.

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to

BCS-135, "Removal and Installation"

.

NO

>> Repair or replace harness.

Monitor item

Status

DOOR LOCK IND

ON

Door lock status indicator

Turns ON

OFF

Turns OFF

(+)

(–)

Voltage

Indicator unit

Connector

Terminal

M4

5

Ground

9 – 16 V

BCM

Indicator unit

Continuity

Connector

Terminal

Connector

Terminal

M69

111

M4

5

Existed

BCM

Ground

Continuity

Connector

Terminal

M69

111

Not existed

DLK-430

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

DOOR SWITCH

DOOR SWITCH

Component Function Check

INFOID:0000000010502778

1.

CHECK FUNCTION

1.

Select “DOOR LOCK” of “BCM” using CONSULT.

2.

Select “DOOR SW-DR”, “DOOR SW-AS”, “DOOR SW-RL”, “DOOR SW-RR”, “DOOR SW-BK” in “DATA
MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Door switch is OK.

NO

>> Refer to

DLK-430, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000010502779

1.

CHECK DOOR SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect malfunctioning door switch connector.

3.

Check signal between malfunctioning door switch harness connector and ground.

Is the inspection result normal?

YES-1 >> Back door: GO TO 3.
YES-2 >> Other door: GO TO 4.
NO

>> GO TO 2.

2.

CHECK DOOR SWITCH CIRCUIT

1.

Disconnect BCM connector.

2.

Check continuity between door switch harness connector and BCM harness connector.

Monitor item

Condition

Status

DOOR SW-DR

Driver side door

Open

On

Closed

Off

DOOR SW-AS

Passenger side door

Open

On

Closed

Off

DOOR SW-RL

Rear door LH

Open

On

Closed

Off

DOOR SW-RR

Rear door RH

Open

On

Closed

Off

DOOR SW-BK

Back door

Open

On

Closed

Off

(+)

(–)

Voltage

Door switch

Connector

Terminal

Driver side

B92

3

Ground

9 - 16 V

Passenger side

B55

Rear LH

B56

Rear RH

B93

Back door

B2

DOOR SWITCH

DLK-431

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

3.

Check continuity between door switch harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to

BCS-135, "Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK BACK DOOR SWITCH CIRCUIT

Check continuity between back door lock assembly harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK DOOR SWITCH

Refer to

DLK-431, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace malfunctioning door switch.

5.

CHECK INTERMITTENT INCIDENT

Refer to

GI-44, "Intermittent Incident"

.

>> INSPECTION END

Component Inspection

INFOID:0000000010502780

1.

CHECK DOOR SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect malfunctioning door switch connector.

3.

Check continuity between door switch terminals.

Door switch

BCM

Continuity

Connector

Terminal

Connector

Terminal

Driver side

B92

3

B4

17

Existed

Passenger side

B55

13

Rear LH

B56

12

Rear RH

B93

10

Back door

B2

11

Door switch

Ground

Continuity

Connector

Terminal

Driver side

B92

3

Not existed

Passenger side

B55

Rear LH

B56

Rear RH

B93

Back door

B2

Back door lock assembly

Ground

Continuity

Connector

Terminal

B2

4

Existed

DLK-432

< DTC/CIRCUIT DIAGNOSIS >

[TYPE 3]

DOOR SWITCH

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace malfunction door switch.

Door switch

Condition

Continuity

Terminal

Driver side

3

Ground part of door

switch

Door switch

Pressed

Existed

Released

Not existed

Passenger side

Pressed

Existed

Released

Not existed

Rear LH

Pressed

Existed

Released

Not existed

Rear RH

Pressed

Existed

Released

Not existed

Back door

3

4

Back door lock as-

sembly

Lock

Existed

Unlock

Not existed