Nissan Teana J32. Manual — part 881
PG
BATTERY
PG-3
< BASIC INSPECTION >
[POWER SUPPLY&GROUND CIRCUIT]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
BASIC INSPECTION
BATTERY
How to Handle Battery
INFOID:0000000003809460
CAUTION:
• If it becomes necessary to start the engine with a booster battery and jumper cables, use a 12-volt
booster battery.
• After connecting battery cables, ensure that they are tightly clamped to battery terminals for good
contact.
• Never add distilled water through the hole used to check specific gravity.
METHODS OF PREVENTING OVER-DISCHARGE
The following precautions must be taken to prevent over-discharging a battery.
• The battery surface (particularly its top) should always be kept
clean and dry.
• The terminal connections should be clean and tight.
• At every routine maintenance, check the electrolyte level.
This also applies to batteries designated as “low maintenance” and
“maintenance-free”.
• When the vehicle is not going to be used over a long period of
time, disconnect the battery cable from the negative terminal. (If
the vehicle has an extended storage switch, turn it off.)
• Check the charge condition of the battery.
Periodically check the specific gravity of the electrolyte. Keep a
close check on charge condition to prevent over-discharge.
CHECKING ELECTROLYTE LEVEL
WARNING:
Never allow battery fluid to come in contact with skin, eyes, fabrics, or painted surfaces. After touch-
ing a battery, never touch or rub your eyes until you have thoroughly washed your hands. If acid con-
tacts eyes, skin or clothing, immediately flush with water for 15 minutes and seek medical attention.
MEL040F
ELA0349D
MEL042F
PG-4
< BASIC INSPECTION >
[POWER SUPPLY&GROUND CIRCUIT]
BATTERY
• Remove the cell plug using a suitable tool.
• Add distilled water up to the MAX level.
Sulphation
A battery will be completely discharged if it is left unattended
for a long time and the specific gravity will become less than
1.100. This may result in sulphation on the cell plates.
To determine if a battery has been “sulphated”, note its voltage
and current when charging it. As shown in the figure, less cur-
rent and higher voltage are observed in the initial stage of
charging sulphated batteries.
A sulphated battery may sometimes be brought back into ser-
vice by means of a long, slow charge, 12 hours or more, fol-
lowed by a battery capacity test.
SPECIFIC GRAVITY CHECK
1.
Read hydrometer and thermometer indications at eye level.
2.
Convert into specific gravity at 20
°
C (68
°
F).
Example:
• When electrolyte temperature is 35
°
C (95
°
F) and specific gravity of
electrolyte is 1.230, converted specific gravity at 20
°
C (68
°
F) is
1.240.
• When electrolyte temperature is 0
°
C (32
°
F) and specific gravity of
electrolyte is 1.210, converted specific gravity at 20
°
C (68
°
F) is
1.196.
MEL043F
PKIA2353E
MEL042FA
SEL007Z
PG
BATTERY
PG-5
< BASIC INSPECTION >
[POWER SUPPLY&GROUND CIRCUIT]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
Work Flow
INFOID:0000000003809461
OVERALL SEQUENCE
DETAILED FLOW
1.
VISUAL INSPECTION
1.
Check battery case for cracks or bends.
2.
Check battery terminals for damage.
JPMIA0184GB
PG-6
< BASIC INSPECTION >
[POWER SUPPLY&GROUND CIRCUIT]
BATTERY
3.
If the difference between the max. and min. electrolyte level in cells is within 10 mm (0.39 in), it is OK.
Are these inspection results normal?
YES
>> GO TO 2.
NO
>> Replace battery.
2.
CHECKING SPECIFIC GRAVITY
Check specific gravity. Refer to
.
Inspection results
Above 1.220 (Test using battery checker)>>GO TO 3.
Above 1.220 (Test using load tester)>>GO TO 5.
1.100 - 1.220 (When performing quick charge)>>GO TO 7.
1.100 - 1.220 (When performing standard charge)>>GO TO 12.
Below 1.100>>GO TO 13.
3.
CAPACITY TEST
Test using battery checker.
Is the battery usable, according to the manufacturer’s instructions?
YES
>> Ready for use. Mount battery again and check loose terminals. Also check other related circuits.
NO
>> GO TO 4.
4.
QUICK CHARGE
1.
Perform quick charge. Time required: 45 min. Refer to
.
2.
Test using battery checker.
Is the battery usable, according to the manufacturer’s instructions?
YES
>> Ready for use.
NO
>> Replace battery.
5.
CAPACITY TEST
1.
Test using load tester.
2.
Check battery type and determine the specified current using the table.
Discharging Current (Load Tester)
3.
Read load tester voltage when specified discharging current flows through battery for 15 seconds.
Type
Current (A)
28B19R(L)
90
34B19R(L)
99
46B24R(L)
135
55B24R(L)
50D23R(L)
150
55D23R(L)
180
80D23R(L)
195
65D26R(L)
80D26R(L)
75D31R(L)
210
95D31R(L)
240
115D31R(L)
025 [YUASA type code]
027 [YUASA type code]
285
110D26R(L)
300
95E41R(L)
067 [YUASA type code]
325
130E41R(L)
330
096 [YUASA type code]
375