Nissan Teana J32. Manual — part 907
PG
BATTERY CHARGING CHART
PG-107
< ON-VEHICLE MAINTENANCE >
[POWER SUPPLY&GROUND CIRCUIT]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
>> Complete standard charge. Perform “CAPACITY TEST”. Refer to
CAUTION:
• Never use standard charge method on a battery whose specific gravity is less than 1.100.
• Set charging current to value specified in “Initial Charging Current Setting (Standard Charge)”. If
charger is not capable of producing specified current value, set its charging current as close to that
value as possible.
• Keep battery away from open flame while it is being charged.
• When connecting charger, connect leads first, then turn on charger. Never turn on charger first, as
this may cause a spark.
• If battery temperature rises above 55
°
C (131
°
F), stop charging. Always charge battery when its tem-
perature is below 55
°
C (131
°
F).
Quick Charge
INFOID:0000000003809464
1.
DETERMINE INITIAL CHARGING CURRENT
1.
Determine initial charging current setting and charging time from specific gravity.
2.
Check battery type and determine the specified current using the table.
NOTE:
After starting charging, adjustment of charging current is not necessary.
Initial Charging Current Setting and Charging Time (Quick Charge)
CAUTION:
• Never use quick charge method on a battery whose specific gravity is less than 1.100.
• Set initial charging current to value specified in “Initial Charging Current Setting and Charging Time
(Quick Charge)”. If charger is not capable of producing specified current value, set its charging cur-
rent as close to that value as possible.
• Keep battery away from open flame while it is being charged.
• When connecting charger, connect leads first, then turn on charger. Never turn on charger first, as
this may cause a spark.
• Be careful of a rise in battery temperature because a large current flow is required during quick-
charge operation.
If battery temperature rises above 55
°
C (131
°
F), stop charging. Always charge battery when its tem-
perature is below 55
°
C (131
°
F).
• Never exceed the charging time specified in “Initial Charging Current Setting and Charging Time
(Quick Charge)”, because charging battery over the charging time can cause deterioration of the
battery.
BATTERY TYPE
28B
19
R(L
)
34B
19
R(L
)
46B
24
R(L
)
55B
24
R(L
)
50
D23R(L
)
55
D23R(L
)
80
D23R(L
)
65
D26R(L
)
80
D26R(L
)
0
2
5
[YUAS
A
type
code
]
0
2
7
[YUAS
A
type
code
]
0
6
7
[YUAS
A
type
code
]
0
9
6
[YUAS
A
type
code
]
75
D31R(L
)
95
D31R(L
)
1
1
5
D
31R(L
)
1
1
0
D
26R(L
)
95E
41
R(L
)
13
0E4
1
R(L
)
CURRENT [A]
10
15
20
25
30
40
C
O
NVER
TED S
PECIFIC
GRA
V
IT
Y
1.100 -
1.130
2.5 hours
1.130 -
1.160
2.0 hours
1.160 -
1.190
1.5 hours
1.190 -
1.220
1.0 hour
Above
1.220
0.75 hour (45 min.)
PG-108
< ON-VEHICLE MAINTENANCE >
[POWER SUPPLY&GROUND CIRCUIT]
BATTERY CHARGING CHART
>> GO TO 2.
2.
CHARGE BATTERY
Charge battery.
>> Complete quick charge. Perform “CAPACITY TEST”. Refer to
.
PG
BATTERY
PG-109
< ON-VEHICLE REPAIR >
[POWER SUPPLY&GROUND CIRCUIT]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
ON-VEHICLE REPAIR
BATTERY
Exploded View
INFOID:0000000003792690
Removal and Installation
INFOID:0000000003792691
REMOVAL
1.
Remove air duct (inlet). Refer to
2.
Remove the nut and bolt (1) and remove the bracket (2) from the
battery fix frame.
3.
Remove cover of battery positive terminal.
4.
Loosen battery terminal nuts (1), and disconnect both battery
cables from battery terminals.
CAUTION:
When disconnecting, disconnect the battery cable from the
negative terminal first.
5.
Remove battery fix frame mounting nuts (2) and battery fix
frame (3).
6.
Remove battery.
INSTALLATION
Install in the reverse order of removal.
CAUTION:
When connecting, connect the battery cable to the positive terminal first.
1
: Battery fix frame
2
: Battery fix frame mounting nuts
3
: Battery terminal (-)
4
: Battery terminal (+)
JPMIA1019ZZ
JPMIA1020ZZ
JPMIA1021ZZ
Battery fix frame mounting nut
: 3.92 N·m (0.40 kg-m, 35 in-lb)
Battery terminal nut
: 5.4 N·m (0.55 kg-m, 48 in-lb)
PG-110
< ON-VEHICLE REPAIR >
[POWER SUPPLY&GROUND CIRCUIT]
BATTERY
Reset electronic systems as necessary. Refer to
GI-48, "ADDITIONAL SERVICE WHEN REMOVING BAT-
TERY NEGATIVE TERMINAL : Required Procedure After Battery Disconnection"