Nissan Teana J32. Manual — part 660
INSPECTION AND ADJUSTMENT
HAC-9
< BASIC INSPECTION >
[WITHOUT 7 INCH DISPLAY]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
4.
CHECK INTAKE AIR
1.
Press the REC switch. REC indicator is turned ON.
2.
Press the FRE switch. FRE indicator is turned ON.
3.
Listen for the intake door position change. (Slight change of blower sound can be heard.)
NOTE:
Confirm that the compressor clutch is engaged (sound or visual inspection) and the intake door position is at
the FRE when the DEF is selected.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Intake door system malfunction:
.
5.
CHECK A/C SWITCH
1.
Press the A/C switch.
2.
The A/C switch indicator is turned ON.
Confirm that the compressor clutch engages (sound or visual inspection).
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Magnet clutch system malfunction:
6.
CHECK WITH TEMPERATURE SETTING LOWERED
1.
Operate the compressor.
2.
Operate the temperature control switch (driver side) and lower the temperature setting to 18
°
C (60
°
F).
3.
Check that the cool air blows from the outlets.
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> Insufficient cooling:
HAC-88, "Inspection procedure"
.
7.
CHECK WITH TEMPERATURE SETTING RAISED
1.
Operate the temperature control switch (driver side) and raise the temperature setting to 32
°
C (90
°
F) after
warming up the engine.
2.
Check that the warm air blows from the outlets.
Is the inspection result normal?
YES
>> GO TO 8.
NO
>> Insufficient heating:
HAC-91, "Inspection procedure"
8.
CHECK LEFT AND RIGHT VENTILATION TEMPERATURE SEPARATELY CONTROL SYSTEM FUNC-
TION
1.
Press the DUAL switch, and then check that “DUAL” is shown on the display.
2.
Operate the temperature control switch (driver side). Check that the discharge air temperature (driver
side) changes.
3.
Operate the temperature control switch (passenger side). Check that the discharge air temperature (pas-
senger side) changes.
4.
Press the DUAL switch, and then check that the temperature setting (LH/RH) is unified to the driver side
temperature setting.
Is the inspection result normal?
YES
>> GO TO 9.
NO
>> Refer to
HAC-87, "Diagnosis Chart By Symptom"
and perform the appropriate diagnosis.
9.
CHECK AUTO MODE
1.
Press the AUTO switch, and then check that “AUTO” is shown on the display.
2.
Operate the temperature control switch (driver side). Check that the fan speed or outlet changes (the dis-
charge air temperature or fan speed varies depending on the ambient temperature, in-vehicle tempera-
ture, and temperature setting).
Is the inspection result normal?
YES
>> GO TO 10.
NO
>> Refer to
HAC-87, "Diagnosis Chart By Symptom"
and perform the appropriate diagnosis.
HAC-10
< BASIC INSPECTION >
[WITHOUT 7 INCH DISPLAY]
INSPECTION AND ADJUSTMENT
10.
CHECK AUTO MODE
1.
Press the AUTO switch, and then check that “AUTO” is shown on the display.
2.
Operate the temperature control switch (driver side). Check that the fan speed or outlet changes (the dis-
charge air temperature or fan speed varies depending on the ambient temperature, in-vehicle tempera-
ture, and temperature setting).
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Refer to
HAC-87, "Diagnosis Chart By Symptom"
and perform the appropriate diagnosis.
Temperature Setting Trimmer
INFOID:0000000003846292
DESCRIPTION
If the temperature felt by the customer is different than the air flow temperature controlled by the temperature
setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting.
HOW TO SET
Using CONSULT-III, perform “TEMP SET CORRECT” on “WORK SUPPORT” of HVAC.
NOTE:
• When the temperature setting is set to 25.0
°
C (77
°
F) and
−
3.0
°
C (
−
6
°
F), the temperature controlled by A/C
auto amp. is 25.0
°
C (77
°
F)
−
3.0
°
C (6
°
F) = 22.0
°
C (71
°
F) and the temperature becomes lower than the tem-
perature setting.
• When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10
V or less, trimmer operation is canceled. Temperature set becomes that of initial condition.
Foot Position Setting Trimmer
INFOID:0000000003846293
DESCRIPTION
In the FOOT mode, the air blowing to the DEF can be turned ON/OFF.
HOW TO SET
Using CONSULT-III, perform “BLOW SET” on “WORK SUPPORT” of HVAC.
Work support items
Display (
°
F)
Display (
°
C)
TEMP SET CORRECT
6
3.0
5
2.5
4
2.0
3
1.5
2
1.0
1
0.5
0 (initial status)
0 (initial status)
−
1
−
0.5
−
2
−
1.0
−
3
−
1.5
−
4
−
2.0
−
5
−
2.5
−
6
−
3.0
Work support items
Display
DEF door position
Auto control
Manual control
BLOW SET
Mode 1
OPEN
CLOSE
Mode 2 (initial status)
OPEN
OPEN
Mode 3
CLOSE
OPEN
Mode 4
CLOSE
CLOSE
INSPECTION AND ADJUSTMENT
HAC-11
< BASIC INSPECTION >
[WITHOUT 7 INCH DISPLAY]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
NOTE:
When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V
or less, trimmer operation is cancelled. Wind distribution rate set becomes that of initial condition.
Inlet Port Memory Function (FRE)
INFOID:0000000003846294
DESCRIPTION
• If the ignition switch is turned to the OFF position while the FRE switch is set to ON (fresh air intake), “Per-
form the memory” or “Do not perform the memory” of the FRE switch ON (fresh air intake) condition can be
selected.
• If “Perform the memory” was set, the FRE switch will be ON (fresh air intake) when turning the ignition switch
to the ON position again.
• If “Do not perform the memory” was set, the air inlets will be controlled automatically when turning the igni-
tion switch to the ON position again.
HOW TO SET
Using CONSULT-III, perform “FRE MEMORY SET” on “WORK SUPPORT” of HVAC.
NOTE:
When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V
or less, the setting of the FRE switch memory function may be cancelled.
Inlet Port Memory Function (REC)
INFOID:0000000003846295
DESCRIPTION
• If the ignition switch is turned to the OFF position while the REC switch is set to ON (recirculation), “Perform
the memory” or “Do not perform the memory” of the REC switch ON (recirculation) condition can be
selected.
• If “Perform the memory” was set, the REC switch will be ON (recirculation) when turning the ignition switch
to the ON position again.
• If “Do not perform the memory” was set, the air inlets will be controlled automatically when turning the igni-
tion switch to the ON position again.
HOW TO SET
Using CONSULT-III, perform “REC MEMORY SET” on “WORK SUPPORT” of HVAC.
NOTE:
When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V
or less, the setting of the REC switch memory function may be cancelled.
Work support items
Display
Setting
FRE MEMORY SET
WITHOUT (initial status)
Perform the memory of manual FRE
WITH
Do not perform the memory of manual FRE (auto control)
Work support items
Display
Setting
REC MEMORY SET
WITHOUT
Perform the memory of manual REC
WITH (initial status)
Do not perform the memory of manual REC (auto control)
HAC-12
< FUNCTION DIAGNOSIS >
[WITHOUT 7 INCH DISPLAY]
COMPRESSOR CONTROL FUNCTION
FUNCTION DIAGNOSIS
COMPRESSOR CONTROL FUNCTION
Description
INFOID:0000000003846298
PRINCIPLE OF OPERATION
Compressor is not activated.
Functional circuit diagram
Functional initial inspection chart
CAN (1)
: A/C switch signal
: Blower fan motor switch signal
CAN (2)
: A/C Compressor request signal
RX
: A/C switch signal
: Fan ON signal
: Defroster signal
JPIIA0483GB
Control unit
Diagnosis Item
Location
A
B
C
D
A/C auto amp.
“HVAC”
Self-diagnosis
Yes
Data monitor
Yes
Active test
Yes
Yes
ECM
“ENGINE”
Self-diagnosis
(CAN system diagnosis)
Yes
Data monitor
Yes
Yes
IPDM E/R
“IPDM E/R”
Self-diagnosis
(CAN system diagnosis)
Yes
Data monitor
Yes
Auto active test
Yes