Nissan Tiida C11. Manual — part 908
HAC-296
< ECU DIAGNOSIS >
[AUTO AIR CONDITIONER (W/NAVI)]
PTC HEATER CONTROL SYSTEM
ALIIA0142GB
PTC HEATER CONTROL SYSTEM
HAC-297
< ECU DIAGNOSIS >
[AUTO AIR CONDITIONER (W/NAVI)]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
ALIIA0143GB
HAC-298
< SYMPTOM DIAGNOSIS >
[AUTO AIR CONDITIONER (W/NAVI)]
AIR CONDITIONER CONTROL
SYMPTOM DIAGNOSIS
AIR CONDITIONER CONTROL
Symptom Matrix Chart
INFOID:0000000001547373
SYMPTOM TABLE
Symptom
Reference Page
A/C system does not come on.
Go to Trouble Diagnosis Procedure for A/C System.
Air outlet does not change.
Go to Trouble Diagnosis Procedure for Mode Door Motor.
Mode door motor does not operate normally.
Discharge air temperature does not change.
Go to Trouble Diagnosis Procedure for Air Mix Door Motor.
Air mix door motor does not operate normally.
Intake door does not change.
Go to Trouble Diagnosis Procedure for Intake Door Motor.
Intake door motor does not operate normally.
Blower motor operation is malfunctioning.
Go to Trouble Diagnosis Procedure for Blower Motor.
Blower motor operation is malfunctioning un-
der out of starting fan speed control.
Magnet clutch does not engage.
Go to Trouble Diagnosis Procedure for Magnet Clutch.
Insufficient cooling
Go to Trouble Diagnosis Procedure for Insufficient Cooling.
Insufficient heating
Go to Trouble Diagnosis Procedure for Insufficient Heating.
Noise
Go to Trouble Diagnosis Procedure for Noise.
Self-diagnosis cannot be performed.
Go to Trouble Diagnosis Procedure for Self-diagnosis.
Memory function does not operate.
Go to Trouble Diagnosis Procedure for Memory Function.
INSUFFICIENT COOLING
HAC-299
< SYMPTOM DIAGNOSIS >
[AUTO AIR CONDITIONER (W/NAVI)]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
INSUFFICIENT COOLING
Component Function Check
INFOID:0000000001547374
SYMPTOM: Insufficient cooling
INSPECTION FLOW
1.
CONFIRM SYMPTOM BY PERFORMING OPERATIONAL CHECK - TEMPERATURE DECREASE
1.
Press the AUTO switch.
2.
Turn temperature control dial counterclockwise until 18
°
C (60
°
F) is displayed.
3.
Check for cold air at discharge air outlets.
Can the symptom be duplicated?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK FOR ANY SYMPTOMS
Perform a complete operational check for any symptoms. Refer to
.
Does another symptom exist?
YES
>> Refer to
HAC-298, "Symptom Matrix Chart"
NO
>> System OK.
3.
CHECK FOR SERVICE BULLETINS
Check for any service bulletins.
>> GO TO 3.
4.
PERFORM SELF-DIAGNOSIS
Perform self-diagnosis Refer to
HAC-213, "Front Air Control Self-Diagnosis"
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Refer to
HAC-218, "Front Air Control Self-Diagnosis Code Chart"
.
5.
CHECK DRIVE BELTS
Check compressor belt tension. Refer to
EM-142, "Checking Drive Belts"
HR18DE or
EM-263, "Inspection and Adjustment"
K9K.
Is the inspection result normal?
OK
>> GO TO 6.
NG
>> Adjust or replace compressor belt. Refer to
XX-XX, "*****"
.
6.
CHECK AIR MIX DOOR OPERATION
Check and verify air mix door mechanism for smooth operation. Refer to
HAC-225, "Air Mix Door Motor Com-
Does air mix door operate correctly?
YES
>> GO TO 7.
NO
>> Check air mix door motor circuit. Refer to
HAC-226, "Air Mix Door Motor Diagnosis Procedure"
.
7.
CHECK COOLING FAN MOTOR OPERATION
Check and verify cooling fan motor for smooth operation.
Does cooling fan motor operate correctly?
YES
>> GO TO 8.
NO
>> Check cooling fan motor. Refer to
CO-18, "Component (Models with A/C)"
.
8.
CHECK RECOVERY/RECYCLING EQUIPMENT BEFORE USAGE
Check recovery/recycling equipment before connecting to vehicle. Verify there is no pressure in the recovery/
recycling equipment by checking the gauges. If pressure exists, recover refrigerant from equipment lines.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст