Nissan Frontier. Manual — part 913
HAC-206
< WIRING DIAGRAM >
[MANUAL A/C (TYPE 2)]
AIR CONDITIONER CONTROL
ABIIA1257GB
MANUAL A/C IDENTIFICATION TABLE
HAC-207
< SYMPTOM DIAGNOSIS >
[MANUAL A/C (TYPE 2)]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
SYMPTOM DIAGNOSIS
MANUAL A/C IDENTIFICATION TABLE
Application Table
INFOID:0000000009478411
Manual A/C Type
Description
Visual Identification
Manual A/C (Type 1)
Two Control Dial System
[with variable blower control
(VBC)]
Manual A/C (Type 2)
Three Control Dial System
[without variable blower con-
trol (VBC)]
AWIIA0481ZZ
AWIIA1228ZZ
HAC-208
< SYMPTOM DIAGNOSIS >
[MANUAL A/C (TYPE 2)]
AIR CONDITIONER CONTROL
AIR CONDITIONER CONTROL
Symptom Matrix Chart
INFOID:0000000009478412
SYMPTOM TABLE
Symptom
Reference Page
A/C system does not come on.
Go to Trouble Diagnosis Procedure for A/C System.
Air outlet does not change.
Go to Trouble Diagnosis Procedure for Mode Door Motor.
Mode door motor is malfunctioning.
Discharge air temperature does not change.
Go to Trouble Diagnosis Procedure for Air Mix Door Motor.
Air mix door motor is malfunctioning.
Intake door does not change.
Go to Trouble Diagnosis Procedure for Intake Door Motor.
Intake door motor is malfunctioning.
Front blower motor operation is malfunctioning. Go to Trouble Diagnosis Procedure for Front Blower Motor.
Magnet clutch does not engage.
Go to Trouble Diagnosis Procedure for Magnet Clutch.
Insufficient cooling
Go to Trouble Diagnosis Procedure for Insufficient Cooling.
Insufficient heating
Go to Trouble Diagnosis Procedure for Insufficient Heating.
Noise
Go to Trouble Diagnosis Procedure for Noise.
INSUFFICIENT COOLING
HAC-209
< SYMPTOM DIAGNOSIS >
[MANUAL A/C (TYPE 2)]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
INSUFFICIENT COOLING
Component Function Check
INFOID:0000000009478413
SYMPTOM: Insufficient cooling
INSPECTION FLOW
1.
CONFIRM SYMPTOM BY PERFORMING OPERATIONAL CHECK - TEMPERATURE DECREASE
1. Turn temperature control dial counterclockwise to maximum cold.
2. Check for cold air at discharge air outlets.
Can the symptom be duplicated?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK FOR ANY SYMPTOMS
Perform a complete operational check for any symptoms. Refer to
.
Does another symptom exist?
YES
>> Refer to
HAC-208, "Symptom Matrix Chart"
NO
>> System OK.
3.
CHECK FOR SERVICE BULLETINS
Check for any service bulletins.
>> GO TO 4.
4.
CHECK DRIVE BELTS
Check compressor belt tension. Refer to
EM-129, "Checking Drive Belts"
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Adjust or replace compressor belt. Refer to
.
5.
CHECK AIR MIX DOOR OPERATION
Check and verify air mix door mechanism for smooth operation.
Does air mix door operate correctly?
YES
>> GO TO 6.
NO
>> Repair or replace air mix door control linkage.
6.
CHECK COOLING FAN MOTOR OPERATION
Check and verify cooling fan motor for smooth operation. Refer to
EC-925, "Component Inspection"
.
Does cooling fan motor operate correctly?
YES
>> GO TO 7.
NO
>> Check cooling fan motor. Refer to
.
7.
CHECK RECOVERY/RECYCLING EQUIPMENT BEFORE USAGE
Check recovery/recycling equipment before connecting to vehicle. Verify there is no pressure in the recovery/
recycling equipment by checking the gauges. If pressure exists, recover refrigerant from equipment lines.
>> GO TO 8.
8.
CHECK REFRIGERANT PURITY
1. Connect recovery/recycling equipment to vehicle.
2. Confirm refrigerant purity in supply tank using recovery/recycling and refrigerant identifier.
Is the inspection result normal?
YES
>> GO TO 9.
NO
>> Check contaminated refrigerant. Refer to
HA-3, "Contaminated Refrigerant"
.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.