REAR SONAR SYSTEM
SN-5
< SYSTEM DESCRIPTION >
C
D
E
F
G
H
I
J
K
L
M
B
A
O
P
SYSTEM DESCRIPTION
REAR SONAR SYSTEM
System Diagram
INFOID:0000000009480099
System Description
INFOID:0000000009480100
FUNCTION
With power and ground supplied, transmission gear selector lever in R position, and the sonar system OFF
switch ON, the rear sonar system will detect obstacles within 1.8 m (5.9 ft.) of the rear sonar sensors. The
vehicle operator is notified of obstacles by varied rate of tone from the rear sonar buzzer depending on dis-
tance of obstacle being sensed.
SONAR SYSTEM OFF SWITCH
With power and ground supplied to the sonar control unit, transmission gear selector lever in R position, the
sonar system can be disabled and the sonar buzzer silenced by momentarily pressing the sonar system OFF
switch. The sonar system OFF indicator lamp will be illuminated in the sonar system OFF switch.
The rear sonar system and buzzer will be disabled and the sonar system OFF indicator will be illuminated until
the ignition switch is turned OFF. When the ignition switch is turned ON, the rear sonar system will be enabled.
Depressing the sonar system OFF switch again will enable the rear sonar system also. Enabling the rear
sonar system will cause the rear sonar system OFF indicator to go out. If the sonar control unit detects a mal-
function in the system it will turn off the sonar system and the indicator lamp will turn on.
REAR SONAR BUZZER
With power and ground supplied to the sonar control unit and the A/T selector lever in R position, a stationary
object that is at least 7.0 cm (2.8 in.) wide and 1.0 m (39.0 in.) tall and that is closer than 1.8 m (5.9 ft.) will be
detected by the rear sonar sensors, causing the rear sonar buzzer to sound a tone. As the vehicle moves
closer to the object, the rate of the tone will increase. When the object is less than 25.0 cm (10 in.) from the
rear bumper, the tone will sound continuously.
REAR SONAR SENSORS
With power and ground supplied to the rear sonar sensors, the sonar sensors transmit an ultrasonic signal.
This signal is reflected back to the sensor by objects large enough and close enough to be detected. The rear
sonar sensors measure the time from the transmitted signal to the time the signal is reflected back and sends
this information to the sonar control unit.
BACK-UP LAMP RELAY (WITH A/T)
The back-up lamp relay provides a reverse signal to the sonar control unit.
BACK-UP LAMP SWITCH (WITH M/T)
The back-up lamp switch provides a reverse signal to the sonar control unit.
AWNIA3304GB
SN-6
< SYSTEM DESCRIPTION >
REAR SONAR SYSTEM
Component Parts Location
INFOID:0000000009480101
Component Description
INFOID:0000000009480102
1.
Sonar control unit M93 (above left low-
er dash side finisher)
2.
Rear sonar buzzer M92 (view with
combination meter removed)
3.
Sonar system OFF switch M94
4.
Back-up lamp relay E45 (with A/T)
5.
Back-up lamp switch F69 (with M/T)
6.
Rear sonar sensor LH outer C227
7.
Rear sonar sensor LH inner C228
8.
Rear sonar sensor RH inner C229
9.
Rear sonar sensor RH outer C230
10.
A/T assembly F9 (with A/T)
ALNIA1500ZZ
Component
Function
Sonar control unit
Controls sonar system and provides self-diagnosis
Back-up lamp relay (with A/T)
Provides reverse signal for sonar control unit
Back-up lamp switch (with M/T)
Provides reverse signal for sonar control unit
A/T assembly
Controls back-up lamp relay
SN
REAR SONAR SYSTEM
SN-7
< SYSTEM DESCRIPTION >
C
D
E
F
G
H
I
J
K
L
M
B
A
O
P
Self-Diagnosis Function
INFOID:0000000009480103
NOTE:
Always perform Preliminary Check before running Self-Diagnosis Function. Refer to
.
There are four modes of self-diagnosis. These modes must be followed in the following order:
1. Entering diagnostics mode
2. Requesting number of fault codes mode
3. Requesting fault codes mode
4. Clearing fault codes mode
Self-diagnosis can be manually exited by turning the ignition OFF or selecting reverse gear. Self-diagnosis will
exit unless a fault code request occurs before a message is repeated five times without acknowledgement.
ENTERING DIAGNOSTICS MODE
1. Turn ignition switch ON. Sonar system OFF switch indicator
lamp illuminates for three seconds and then turns off.
2. Immediately push sonar system OFF switch ten times within five
seconds.
3. The rear sonar buzzer will sound once and the sonar system
OFF indicator will flash once.
REQUESTING NUMBER OF FAULT CODES MODE
1. While in "entering diagnostic mode", push sonar system OFF
switch once within 30 seconds of entering diagnostic mode.
NOTE:
If the number of fault codes is not requested within 30 seconds
after entering diagnostic mode, the system will return to regular
operation mode.
2. The rear sonar buzzer will sound once.
3. Sonar system OFF indicator will flash once and rear sonar
buzzer will sound once for each fault code detected.
4. There will be a four second pause.
5. The number of fault codes will repeat five times then pause.
NOTE:
Self-diagnosis will exit unless "requesting fault codes mode" occurs before five repeats ends.
REQUESTING FAULT CODES MODE
Rear sonar buzzer
Sounds a signal when objects are detected in the rear of the vehicle
Sonar system OFF switch
Enables the driver to turn system off and signals a system malfunction
Sonar sensor
Senses objects in the rear of the vehicle
Component
Function
LKIA0389E
LKIA0388E
SN-8
< SYSTEM DESCRIPTION >
REAR SONAR SYSTEM
1. While in "requesting number of fault codes" mode, push sonar
system OFF switch once.
2. The rear sonar buzzer will sound once.
3. Sonar system OFF indicator will flash and rear sonar buzzer will
sound the first digit of the fault code followed by a one second
pause.
4. Sonar system OFF indicator will flash and rear sonar buzzer will
sound the second digit of the fault code followed by a four sec-
ond pause.
5. Each fault code will repeat five times then pause.
6. Write down each fault code. Then, acknowledge the fault code
by pushing the sonar system OFF switch once (the rear sonar buzzer may sound).
NOTE:
"Requesting fault codes mode" will exit unless the fault code is acknowledged before it is repeated five
times. When all fault codes have been indicated, "clearing fault codes mode" will be entered. Refer to
.
CLEARING FAULT CODES MODE
NOTE:
While in "clearing fault codes mode", self-diagnosis will automatically exit if no activity occurs for 30 seconds.
1. Push and hold sonar system OFF switch for three seconds to
reset time-out counter.
2. Push and hold sonar system OFF switch for three seconds to
clear codes.
LKIA0390E
LKIA0391E