Nissan Pathfinder (2012 year). Manual — part 124
CHG-20
< DTC/CIRCUIT DIAGNOSIS >
S TERMINAL CIRCUIT
S TERMINAL CIRCUIT
Description
INFOID:0000000007355057
The output voltage of the generator is controlled by the IC regulator at terminal “3” (S) detecting the input volt-
age. Terminal “3” circuit detects the battery voltage to adjust the generator output voltage with the IC regulator.
Diagnosis Procedure
INFOID:0000000007355058
Regarding Wiring Diagram information, refer to
1.
CHECK TERMINAL "3" CONNECTION
Check to see if connector E205 terminal 3 is clean and tight.
Is the inspection result normal?
YES
>> GO TO 2
NO
>> Repair terminal "3" connection. Confirm repair by performing complete Charging system test
using EXP-800 NI or GR8-1200 NI (if available). Refer to applicable Instruction Manual for proper
testing procedures.
2.
CHECK VOLTAGE REGULATOR CIRCUIT
Check voltage between generator harness connector E205 terminal 3 and ground.
Is the inspection result normal?
YES
>> Refer to
CHG-5, "Work Flow (With EXP-800 NI or GR8-1200 NI)"
or
.
NO
>> Check harness for open between generator and fuse.
3 - ground
Battery voltage
August 2012
2012 Pathfinder
CHG
CHARGING SYSTEM
CHG-21
< WIRING DIAGRAM >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
WIRING DIAGRAM
CHARGING SYSTEM
Wiring Diagram
INFOID:0000000007355059
ABMWA1423GB
August 2012
2012 Pathfinder
CHG-22
< WIRING DIAGRAM >
CHARGING SYSTEM
ABMIA3473GB
August 2012
2012 Pathfinder
CHG
CHARGING SYSTEM
CHG-23
< WIRING DIAGRAM >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
ABMIA3474GB
August 2012
2012 Pathfinder
CHG-24
< WIRING DIAGRAM >
CHARGING SYSTEM
ABMIA3475GB
August 2012
2012 Pathfinder
CHG
CHARGING SYSTEM
CHG-25
< WIRING DIAGRAM >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
ABMIA3476GB
August 2012
2012 Pathfinder
CHG-26
< WIRING DIAGRAM >
CHARGING SYSTEM
ABMIA3477GB
August 2012
2012 Pathfinder
CHG
CHARGING SYSTEM
CHG-27
< SYMPTOM DIAGNOSIS >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
SYMPTOM DIAGNOSIS
CHARGING SYSTEM
Symptom Table
INFOID:0000000007355060
Symptom
Reference
Battery discharged
Refer to
CHG-5, "Work Flow (With EXP-800 NI or GR8-1200 NI)"
or
CHG-8, "Work Flow (Without EXP-800 NI or GR8-1200 NI)"
The charge warning lamp does not illuminate when the ignition
switch is set to ON.
The charge warning lamp does not turn OFF after the engine
starts.
The charging warning lamp turns ON when increasing the engine
speed.
August 2012
2012 Pathfinder
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст