Nissan Sentra. Manual — part 707
DIAGNOSIS AND REPAIR WORKFLOW
PWC-25
< BASIC INSPECTION >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
BASIC INSPECTION
DIAGNOSIS AND REPAIR WORKFLOW
Work Flow
INFOID:0000000009757223
OVERALL SEQUENCE
DETAILED FLOW
1.
OBTAIN INFORMATION ABOUT SYMPTOM
Interview the customer to obtain as much information as possible about the conditions and environment under
which the malfunction occurred.
ALKIA1982GB
PWC-26
< BASIC INSPECTION >
DIAGNOSIS AND REPAIR WORKFLOW
>> GO TO 2.
2.
CONFIRM THE SYMPTOM
Check the malfunction on the vehicle that the customer describes.
Inspect the relation of the symptoms and the condition when the symptoms occur.
>> GO TO 3.
3.
IDENTIFY THE MALFUNCTIONING SYSTEM WITH SYMPTOM DIAGNOSIS
Use Symptom diagnosis from the symptom inspection result in step 2 and then identify where to start perform-
ing the diagnosis based on possible causes and symptoms.
>> GO TO 4.
4.
PERFORM THE COMPONENT DIAGNOSIS OF THE OF THE APPLICABLE SYSTEM
Perform the diagnosis with Component diagnosis of the applicable system.
>> GO TO 5.
5.
REPAIR OR REPLACE THE MALFUNCTIONING PARTS
Repair or replace the specified malfunctioning parts.
>> GO TO 6.
6.
FINAL CHECK
Check that malfunctions are not reproduced when obtaining the malfunction information from the customer,
referring to the symptom inspection result in step 2.
Are the malfunctions corrected?
YES
>> Inspection End.
NO
>> GO TO 3.
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL
PWC-27
< BASIC INSPECTION >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMI-
NAL
Description
INFOID:0000000009757224
When the battery negative terminal is disconnected, the initialization is necessary for normal operation of
power window system.
CAUTION:
The following specified operations can not be performed under the non-initialized condition.
• Auto-up operation
• Anti-pinch function
Work Procedure
INFOID:0000000009757225
1.
SYSTEM INITIALIZATION
Perform system initialization. Refer to
>> GO TO 2.
2.
CHECK ANTI-PINCH FUNCTION
Check anti-pinch function. Refer to
>> END
PWC-28
< BASIC INSPECTION >
ADDITIONAL SERVICE WHEN REPLACING POWER WINDOW MAIN SWITCH
ADDITIONAL SERVICE WHEN REPLACING POWER WINDOW MAIN
SWITCH
Description
INFOID:0000000009757226
When the power window main switch is replaced, the initialization is necessary for normal operation of power
window system.
CAUTION:
The following specified operations can not be performed under the non-initialized condition.
• Auto-up operation
• Anti-pinch function
Work Procedure
INFOID:0000000009757227
1.
SYSTEM INITIALIZATION
Perform system initialization. Refer to
>> GO TO 2.
2.
CHECK ANTI-PINCH FUNCTION
Check anti-pinch function. Refer to
>> END
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.