Nissan Sentra. Manual — part 713
POWER WINDOW MOTOR
PWC-49
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
Is the inspection result normal?
YES
>> Check rear power window switch RH. Refer to
PWC-49, "REAR RH : Component Inspection"
NO
>> Repair or replace harness or connectors.
3.
CHECK REAR POWER WINDOW MOTOR RH
Check rear power window motor RH.
PWC-49, "REAR RH : Component Inspection"
.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-39, "Intermittent Incident"
.
NO
>> Replace rear power window motor RH. Refer to
GW-21, "Removal and Installation"
.
REAR RH : Component Inspection
INFOID:0000000009757263
COMPONENT INSPECTION
1.
CHECK REAR POWER WINDOW MOTOR RH
Check motor operation by connecting the battery voltage directly to rear power window motor RH D304.
Is the inspection result normal?
YES
>> Power window motor is OK.
NO
>> Replace rear power window motor RH. Refer to
GW-21, "Removal and Installation"
.
Rear power window switch RH connector
Terminal
Ground
Continuity
D303
5
No
8
Terminal
Motor condition
(+)
(–)
3
1
DOWN
1
3
UP
PWC-50
< DTC/CIRCUIT DIAGNOSIS >
ENCODER
ENCODER
DRIVER SIDE
DRIVER SIDE : Description
INFOID:0000000009757264
Detects condition of the front power window motor LH operation and transmits to main power window and door
lock/unlock switch as pulse signal.
DRIVER SIDE : Component Function Check
INFOID:0000000009757265
1.
CHECK ENCODER OPERATION
Check front door glass LH perform AUTO open/close operation normally with main power window and door
lock/unlock switch.
Is the inspection result normal?
YES
>> Encoder operation is OK.
NO
>> Refer to
PWC-50, "DRIVER SIDE : Diagnosis Procedure"
DRIVER SIDE : Diagnosis Procedure
INFOID:0000000009757266
Regarding Wiring Diagram information, refer to
.
Encoder Circuit Check
1.
CHECK ENCODER OPERATION
1. Connect front power window motor LH.
2. Turn ignition switch ON.
3. Check signal between main power window and door lock/unlock switch connector D5 and ground with
oscilloscope.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-39, "Intermittent Incident"
.
NO
>> GO TO 2.
2.
CHECK FRONT POWER WINDOW MOTOR LH POWER SUPPLY
1. Turn ignition switch ON.
2. Check voltage between front power window motor LH connector D8 and ground.
Terminals
Signal
(Reference value)
(+)
(–)
Main power window and door lock/
unlock switch
connector
Terminal
D5
4
Ground
Refer to following signal
5
JMKIA5210GB
ENCODER
PWC-51
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> GO TO 3.
3.
CHECK HARNESS CONTINUITY 1
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch and front power window motor LH.
3. Check continuity between main power window and door lock/unlock switch connector D5 and front power
window motor connector D8.
4. Check continuity between main power window and door lock/unlock switch connector D5 and ground.
Is the inspection result normal?
YES
>> Replace main power window and door lock/unlock switch. Refer to
NO
>> Repair or replace harness or connectors.
4.
CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front power window motor LH.
3. Check continuity between front power window motor LH connector D8 and ground.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> GO TO 5.
5.
CHECK HARNESS CONTINUITY 2
1. Disconnect main power window and door lock/unlock switch.
2. Check continuity between main power window and door lock/unlock switch connector D5 and front power
window motor LH connector D8.
Is the inspection result normal?
YES
>> Check main power window and door lock/unlock switch. Refer to
MAIN SWITCH : Component Inspection"
.
NO
>> Repair or replace the harness or connectors.
6.
CHECK HARNESS CONTINUITY 3
1. Disconnect main power window and door lock/unlock switch.
Terminal
Voltage
(Approx.)
(+)
(–)
Front power window motor LH connector
Terminal
D8
2
Ground
Battery voltage
Main power window and door lock/
unlock switch connector
Terminal
Front power window motor LH
connector
Terminal
Continuity
D5
14
D8
2
Yes
Main power window and door lock/unlock switch con-
nector
Terminal
Ground
Continuity
D5
14
No
Front power window motor LH connector
Terminal
Ground
Continuity
D8
6
Yes
Main power window and door lock/un-
lock switch connector
Terminal
Front power window motor LH
connector
Terminal
Continuity
D5
12
D8
6
Yes
PWC-52
< DTC/CIRCUIT DIAGNOSIS >
ENCODER
2. Check continuity between main power window D5 and door lock/unlock switch connector and front power
window motor LH connector D8.
3. Check continuity between main power window and door lock/unlock switch connector D5 and ground.
Is the inspection result normal?
YES
>> Replace front power window motor LH. Refer to
GW-16, "Removal and Installation"
. After that,
NO
>> Repair or replace harness or connectors.
DRIVER SIDE : Special Repair Requirement
INFOID:0000000009757267
1.
PERFORM INITIALIZATION PROCEDURE
Perform initialization procedure.
Is the inspection result normal?
YES
>> Inspection end.
NO
>> Check intermittent incident. Refer to
GI-39, "Intermittent Incident"
.
Main power window and door lock/unlock
switch connector
Terminal
Front power window motor
LH connector
Terminal
Continuity
D5
4
D8
5
Yes
5
4
Main power window and door lock/unlock
switch connector
Terminal
Ground
Continuity
D5
4
No
5
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.