Nissan GT-R. Manual — part 247
PWC-38
< SYMPTOM DIAGNOSIS >
AUTO OPERATION DOES NOT OPERATE NORMALLY
AUTO OPERATION DOES NOT OPERATE NORMALLY
POWER WINDOW MAIN SWITCH IS OPERATED
POWER WINDOW MAIN SWITCH IS OPERATED : Diagnosis Procedure
INFOID:0000000009159957
1.
PERFORM INITIALIZATION PROCEDURE
Perform initialization of power window that is malfunctioning, and check that auto operation operates normally.
Refer to
PWC-4, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special
.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 2.
2.
CHECK POWER WINDOW AUTO CIRCUIT (POWER WINDOW MAIN SWITCH)
Check power window auto circuit (power window main switch).
Refer to
PWC-22, "POWER WINDOW MAIN SWITCH : Component Function Check"
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace the malfunctioning parts.
3.
CONFIRM THE OPERATION
Confirm the operation again.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-38, "Intermittent Incident"
.
NO
>> GO TO 1.
POWER WINDOW SUB-SWITCH IS OPERATED
POWER WINDOW SUB-SWITCH IS OPERATED : Diagnosis Procedure
INFOID:0000000009159958
1.
PERFORM INITIALIZATION PROCEDURE
Perform initialization of power window that is malfunctioning, and check that auto operation operates normally.
Refer to
PWC-4, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special
.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 2.
2.
CHECK POWER WINDOW AUTO CIRCUIT (POWER WINDOW SUB-SWITCH)
Check power window auto circuit (power window sub-switch).
Refer to
PWC-25, "POWER WINDOW SUB-SWITCH : Component Function Check"
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace the malfunctioning parts.
3.
CONFIRM THE OPERATION
Confirm the operation again.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-38, "Intermittent Incident"
.
NO
>> GO TO 1.
POWER WINDOW LOCK SWITCH DOES NOT OPERATE
PWC-39
< SYMPTOM DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
POWER WINDOW LOCK SWITCH DOES NOT OPERATE
Diagnosis Procedure
INFOID:0000000009159959
1.
REPLACE POWER WINDOW MAIN SWITCH
Replace power window main switch.
>> Refer to
PWC-46, "Removal and Installation"
.
PWC-40
< SYMPTOM DIAGNOSIS >
AUTOMATIC WINDOW ADJUSTING FUNCTION DOES NOT OPERATE
AUTOMATIC WINDOW ADJUSTING FUNCTION DOES NOT OPERATE
Diagnosis Procedure
INFOID:0000000009159960
1.
PERFORM INITIALIZATION PROCEDURE
Perform initialization of power window that is malfunctioning, and check that automatic window adjusting func-
tion operates normally.
Refer to
PWC-4, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special
.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 2.
2.
CHECK DOOR SWITCH CIRCUIT
Check door switch circuit.
Refer to
PWC-29, "Component Function Check"
.
Is the inspection result normal?
YES
>> Replace malfunctioning power window motor. Refer to
GW-27, "Removal and Installation (GT-R
NO
>> Repair or replace the malfunctioning parts.
POWER WINDOW SWITCH ILLUMINATION DOES NOT ILLUMINATE
PWC-41
< SYMPTOM DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
POWER WINDOW SWITCH ILLUMINATION DOES NOT ILLUMINATE
POWER WINDOW MAIN SWITCH
POWER WINDOW MAIN SWITCH : Diagnosis Procedure
INFOID:0000000009159961
1.
CHECK POWER WINDOW ILLUMINATION CIRCUIT (POWER WINDOW MAIN SWITCH)
Check power window illumination circuit (power window main switch).
Refer to
PWC-27, "POWER WINDOW MAIN SWITCH : Component Function Check"
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace the malfunctioning parts.
2.
CONFIRM THE OPERATION
Confirm the operation again.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-38, "Intermittent Incident"
.
NO
>> GO TO 1.
POWER WINDOW SUB-SWITCH
POWER WINDOW SUB-SWITCH : Diagnosis Procedure
INFOID:0000000009159962
1.
CHECK POWER WINDOW ILLUMINATION CIRCUIT (POWER WINDOW SUB-SWITCH)
Check power window illumination circuit (power window sub-switch).
Refer to
PWC-27, "POWER WINDOW SUB-SWITCH : Component Function Check"
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace the malfunctioning parts.
2.
CONFIRM THE OPERATION
Confirm the operation again.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-38, "Intermittent Incident"
.
NO
>> GO TO 1.