Nissan Cube. Manual — part 532
PREPARATION
HA-17
< PREPARATION >
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
(J-43926)
Refrigerant dye leak detection
kit
Kit includes:
(J-42220)
UV lamp and UV safety goggles
(J-41459)
HFC-134a (R-134a) dye injector
Use with J-41447, 1/4 ounce
bottle
(J-41447)
HFC-134a (R-134a) fluorescent
leak detection dye
(Box of 24, 1/4 ounce bottles)
(J-43872)
Refrigerant dye cleaner
Power supply:
DC 12 V (Battery terminal)
(J-42220)
UV lamp and UV safety goggles
Power supply:
DC 12 V (Battery terminal)
For checking refrigerant leakage when flu-
orescent dye is equipped in A/C system
Includes:
UV lamp and UV safety goggles
(J-41447)
HFC-134a (R-134a) fluorescent
leak detection dye
(Box of 24, 1/4 ounce bottles)
Application:
For HFC-134a (R-134a) PAG oil
Container:
1/4 ounce (7.4 cc) bottle
(Includes self-adhesive dye identification
labels for affixing to vehicle after charging
system with dye.)
(J-41459)
HFC-134a (R-134a) dye injector
Use with J-41447, 1/4 ounce
bottle
For injecting 1/4 ounce of fluorescent leak
detection dye into A/C system
(J-43872)
Refrigerant dye cleaner
For cleaning dye spills
Tool number
(Kent-Moore No.)
Tool name
Description
ZHA200H
SHA438F
SHA439F
SHA440F
SHA441F
HA-18
< PREPARATION >
PREPARATION
(J-39183)
Manifold gauge set (with hoses
and couplers)
Identification:
• The gauge face indicates HFC-134a (R-
134a).
Fitting size: Thread size
• 1/2
″
-16 ACME
Service hoses
• High-pressure side hose
(J-39501-72)
• Low-pressure side hose
(J-39502-72)
• Utility hose
(J-39476-72)
Hose color:
• Low-pressure side hose: Blue with black
stripe
• High-pressure side hose: Red with black
stripe
• Utility hose: Yellow with black stripe or
green with black stripe
Hose fitting to gauge:
• 1/2
″
-16 ACME
Service couplers
• High-pressure side coupler
(J-39500-20)
• Low-pressure side coupler
(J-39500-24)
Hose fitting to service hose:
M14 x 1.5 fitting is optional or permanently
attached.
(J-39650)
Refrigerant weight scale
For measuring of refrigerant
Fitting size: Thread size
1/2
″
-16 ACME
(J-39649)
Vacuum pump
(Including the isolator valve)
Capacity:
• Air displacement: 4 CFM
• Micron rating: 20 microns
• Oil capacity: 482 g (17 oz.)
Fitting size: Thread size
• 1/2
″
-16 ACME
Tool number
(Kent-Moore No.)
Tool name
Description
RJIA0196E
S-NT201
S-NT202
S-NT200
S-NT203
PREPARATION
HA-19
< PREPARATION >
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
Commercial Service Tool
INFOID:0000000009950335
Sealant or/and Lubricant
INFOID:0000000009950336
HFC-134a (R-134a) Service Tool and Equipment
• Never mix HFC-134a (R-134a) refrigerant and/or its specified lubricant with CFC-12 (R-12) refrigerant and/
or its lubricant.
• Separate and non-interchangeable service equipment must be used for handling each type of refrigerant/
lubricant.
• Refrigerant container fittings, service hose fittings and service equipment fittings (equipment that handles
refrigerant and/or lubricant) are different between CFC-12 (R-12) and HFC-134a (R-134a). This is to avoid
mixed use of the refrigerants/lubricant.
• Never use adapters that convert one size fitting to another. Refrigerant/lubricant contamination occurs and
compressor malfunction may result.
Tool name
Description
Refrigerant identifier equipment
Checking for refrigerant purity and
system contamination
Power tools
For loosening bolts and nuts
RJIA0197E
PBIC0190E
Tool name
Description
HFC-134a (R-134a) refrigerant
Container color: Light blue
Container marking: HFC-134a (R-
134a)
Fitting size: Thread size
• Large container 1/2
″
-16 ACME
A/C System Oil Type R (DH-PR)
Type: Polyalkylene glycol oil (PAG),
type S (DH-PR)
Application:
HFC-134a (R-134a) swash plate com-
pressors
Capacity: 40 m
(1.4 US fl oz., 1.4
Imp fl oz.)
S-NT196
S-NT197
HA-20
< PERIODIC MAINTENANCE >
DESCRIPTION
PERIODIC MAINTENANCE
DESCRIPTION
Service Equipment
INFOID:0000000009950337
RECOVERY/RECYCLING RECHARGING EQUIPMENT
Be certain to follow the manufacturer’s instructions for machine operation and machine maintenance. Never
introduce any refrigerant other than that specified into the machine.
ELECTRICAL LEAK DETECTOR
Be certain to follow the manufacturer’s instructions for tester operation and tester maintenance.
VACUUM PUMP
The lubricant contained inside the vacuum pump is not compatible
with the specified lubricant for HFC-134a (R-134a) A/C systems.
The vent side of the vacuum pump is exposed to atmospheric pres-
sure. So the vacuum pump lubricant may migrate out of the pump
into the service hose. This is possible when the pump is switched
OFF after evacuation (vacuuming) and hose is connected to it.
To prevent this migration, use a manual valve placed near the hose-
to-pump connection, as per the following.
• Vacuum pumps usually have a manual isolator valve as part of the
pump. Close this valve to isolate the service hose from the pump.
• Use a hose equipped with a manual shut-off valve near the pump
end for pumps without an isolator. Close the valve to isolate the
hose from the pump.
• Disconnect the hose from the pump if the hose has an automatic
shut-off valve. As long as the hose is connected, the valve is open
and lubricating oil may migrate.
Some one-way valves open when vacuum is applied and close
under no vacuum condition. Such valves may restrict the pump’s
ability to pull a deep vacuum and are not recommended.
MANIFOLD GAUGE SET
Be certain that the gauge face indicates HFC-134a or R-134a. Be
sure the gauge set has 1/2
″
-16 ACME threaded connections for ser-
vice hoses. Confirm the set has been used only with refrigerant
HFC-134a (R-134a) and specified lubricants.
SERVICE HOSES
RHA270DA
SHA533D