Temperature Setting Trimmer
INFOID:0000000009950967
DESCRIPTION
If the temperature felt by the customer is different than the air flow temperature controlled by the temperature
setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting.
OPERATING PROCEDURES
1.
Begin self-diagnosis STEP 5 mode. Refer to
HAC-26, "Diagnosis Description"
.
2.
Press fan control switch (up: +) to enter the set temperature setting trimmer mode from STEP 5, and then
display shows “0
°
C (0
°
F)”.
3.
The indication temperature will be changed by 1
°
C (1
°
F) in range of
−
3
°
C (
−
6
°
F) to +3
°
C (+6
°
F) by press-
ing the temperature control switch each time.
USA models
Canada models
NOTE:
• When
−
3
°
C (
−
6
°
F) is corrected on the temperature setting set as 25
°
C (75
°
F), the temperature controlled by
A/C auto amp. is 25
°
C (75
°
F)
−
3
°
C (6
°
F) = 22.0
°
C (69
°
F) and the temperature becomes lower than the tem-
perature setting.
• When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10
V or less, the setting of the difference between the set temperature and control temperature may be can-
celled.
Temperature control switch operation
Display
Correction (
°
F)
6 time pressing
6
+6
5 time pressing
5
+5
4 time pressing
4
+4
3 time pressing
3
+3
2 time pressing
2
+2
1 time pressing
1
+1
Initial status
0
0
1 time pressing
AUTO 1
−
1
2 time pressing
AUTO 2
−
2
3 time pressing
AUTO 3
−
3
4 time pressing
AUTO 4
−
4
5 time pressing
AUTO 5
−
5
6 time pressing
AUTO 6
−
6
Temperature control switch operation
Display
Correction (
°
C)
3 time pressing
3
+3
2 time pressing
2
+2
1 time pressing
1
+1
Initial status
0
0
1 time pressing
AUTO 1
−
1
2 time pressing
AUTO 2
−
2
3 time pressing
AUTO 3
−
3
AUXILIARY MECHANISM
HAC-11
< BASIC INSPECTION >
[AUTOMATIC AIR CONDITIONING]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
Inlet Port Memory Function
INFOID:0000000009950968
DESCRIPTION
• Inlet port setting can be memorized when ignition switch is turned OFF.
• Inlet port setting can be selected from FRE (fresh air intake), REC (recirculation), or “Do not perform the
memory” when ignition switch is turned ON.
OPERATING PROCEDURES
1.
Begin self-diagnosis STEP 5 mode. Refer to
HAC-26, "Diagnosis Description"
2.
Press fan control switch (up: +) two times to change the mode to the temperature setting trimmer from
self-diagnosis STEP 5, and then the display shows “70”.
3.
The setting of inlet port memory function can be selected from “70” to “73” by pressing the FRE switch.
*: Initial status
NOTE:
• When FRE switch is pressed four times, display shows "70" again.
• When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting
of the inlet port memory function may be cancelled.
FRE switch operation
Display
Memory function
Manual REC
Manual FRE
—
70
*
Shall be memorized
Shall not be memorized
1 time pressing
71
Shall not be memorized
Shall not be memorized
2 time pressing
72
Shall be memorized
Shall be memorized
3 time pressing
73
Shall not be memorized
Shall be memorized
HAC-12
< SYSTEM DESCRIPTION >
[AUTOMATIC AIR CONDITIONING]
COMPRESSOR CONTROL FUNCTION
SYSTEM DESCRIPTION
COMPRESSOR CONTROL FUNCTION
Description
INFOID:0000000009950969
PRINCIPLE OF OPERATION
Functional Circuit Diagram
Functional Initial Inspection Chart
×
: Applicable
L (1)
: Fan ON signal
CAN (1)
: A/C ON switch signal
: Blower fan ON signal
L (2)
: A/C switch signal
CAN (2)
: A/C compressor request signal
JPIIA1651GB
Control unit
Diagnosis item
Location
A
B
C
D
E
F
A/C auto amp.
On board self-diagnosis
×
—
—
—
—
—
BCM
“BCM-AIR COND”
Self-diagnosis
—
—
×
—
—
—
Data monitor
—
×
—
—
—
—
ECM
“ENGINE”
Self-diagnosis
(CAN communication line)
—
—
—
—
×
—
Data monitor
—
—
×
×
—
—
IPDM E/R
“IPDM E/R”
Self-diagnosis
(CAN communication line)
—
—
—
—
—
×
Data monitor
—
—
—
—
×
—
Auto active test
—
—
—
—
—
×
COMPRESSOR CONTROL FUNCTION
HAC-13
< SYSTEM DESCRIPTION >
[AUTOMATIC AIR CONDITIONING]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
Component Parts Location
INFOID:0000000009950970
Component Description
INFOID:0000000009950971
1.
Sunload sensor
2.
Ambient sensor
3.
Magnet clutch
4.
Refrigerant pressure sensor
5.
A/C control (A/C auto amp.)
6.
In-vehicle sensor
7.
Blower motor
8.
Mode door motor
9.
Power transistor
10.
Intake door motor
11.
Air mix door motor
12.
Intake sensor
A.
Located in the right side of A/C
unit assembly
B.
Located in the back of A/C unit
assembly
C.
Located in left side of A/C unit
assembly
D.
Located on the evaporator
JPIIA1719ZZ
Component
Description
Sunload sensor
Ambient sensor