Nissan Juke F15. Manual — part 853
DIAGNOSIS AND REPAIR WORK FLOW
HAC-47
< BASIC INSPECTION >
[AUTOMATIC AIR CONDITIONING]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
Inspect according to Diagnosis Procedure of the system.
Is malfunctioning part detected?
YES
>> GO TO 8.
NO
>> Check according to
GI-45, "Intermittent Incident"
.
8.
REPAIR OR REPLACE THE MALFUNCTIONING PART
1. Repair or replace the malfunctioning part.
2. Reconnect parts or connectors disconnected during Diagnosis Procedure again after repair and replace-
ment.
3. Check DTC. If DTC is detected, erase it.
>> GO TO 9.
9.
FINAL CHECK
When DTC is detected in step 2, perform DTC CONFIRMATION PROCEDURE again, and then check that the
malfunction is repaired securely.
When symptom is described by the customer, refer to confirmed symptom in step 3 or 4, and check that the
symptom is not detected.
Is DTC detected and does symptom remain?
YES-1 >> DTC is detected: GO TO 7.
YES-2 >> Symptom remains: GO TO 4.
NO
>> Before returning the vehicle to the customer, always erase DTC.
HAC-48
< BASIC INSPECTION >
[AUTOMATIC AIR CONDITIONING]
OPERATION INSPECTION
OPERATION INSPECTION
Work Procedure
INFOID:0000000012200029
The purpose of the operational check is to check that the individual system operates normally.
1.
CHECK MEMORY FUNCTION
1. Set temperature to 32
°C (90°F) by operating the temperature control dial.
2. Press OFF switch.
3. Turn ignition switch OFF.
4. Turn ignition switch ON.
5. Press AUTO switch.
6. Check that set temperature is maintained.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> GO TO 10.
2.
CHECK AIR FLOW
1. Start engine.
2. Operate fan control dial.
3. Check that air flow changes. Check operation for all fan speeds.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 10.
3.
CHECK AIR OUTLET
1. Operate fan control dial to set the fan speed to maximum speed.
2. Operate MODE switch and DEF switch.
3. Check that air outlets change according to each indicated air outlet by placing a hand in front of the air
outlets. Refer to
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> GO TO 10.
4.
CHECK AIR INLET
1. Press intake switch to set the air inlet to recirculation. [Intake switch indicator (
side) turns ON.]
2. Listen to intake sound and confirm air inlets change.
3. Press intake switch again to set the air inlet to fresh air intake. [Intake switch indicator (
side) turns
OFF and (
side) turns ON.]
4. Listen to intake sound and confirm air inlets change.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> GO TO 10.
5.
CHECK COMPRESSOR
1. Press A/C switch. The A/C switch indicator is turns ON.
2. Check visually and by sound that the compressor operates.
3. Press A/C switch again The A/C switch indicator is turns OFF.
4. Check that compressor stops.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> GO TO 10.
6.
CHECK DISCHARGE AIR TEMPERATURE
1. Operate temperature control dial.
2. Check that discharge air temperature changes.
Check condition : Engine running at normal operating temperature.
OPERATION INSPECTION
HAC-49
< BASIC INSPECTION >
[AUTOMATIC AIR CONDITIONING]
C
D
E
F
G
H
J
K
L
M
A
B
HAC
N
O
P
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> GO TO 10.
7.
CHECK TEMPERATURE DECREASE
1. Operate compressor.
2. Operate temperature control dial and lower the set temperature to 18
°C (60°F).
3. Check that cool air blows from the air outlets.
Is the inspection result normal?
YES
>> GO TO 8.
NO
>> GO TO 10.
8.
CHECK TEMPERATURE INCREASE
1. Operate temperature control dial and raise the set temperature to 32
°C (90°F).
2. Check that warm air blows from the air outlets.
Is the inspection result normal?
YES
>> GO TO 9.
NO
>> GO TO 10.
9.
CHECK AUTO MODE
1. Press AUTO switch to confirm that “AUTO” is indicated on the display.
2. Operate temperature control dial to check that air outlet or air flow changes (the air outlet or air flow varies
depending on the ambient temperature, in-vehicle temperature, set temperature, and etc.).
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 10.
10.
CHECK SELF-DIAGNOSIS WITH CONSULT
1. Perform self-diagnosis with CONSULT.
2. Check that any DTC is detected.
Is any DTC detected?
YES
>> Refer to
and perform the appropriate diagnosis.
NO
>> GO TO 11.
11.
CHECK FAIL-SAFE ACTIVATION
Check that symptom is applied to the fail-safe activation. Refer to
.
>> Refer to
and perform the appropriate diagnosis.
HAC-50
< BASIC INSPECTION >
[AUTOMATIC AIR CONDITIONING]
SYSTEM SETTING
SYSTEM SETTING
Temperature Setting Trimmer
INFOID:0000000012200030
DESCRIPTION
If the temperature felt by the customer is different from the air flow temperature controlled by the temperature
setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting.
HOW TO SET
With CONSULT
Perform “TEMP SET CORRECT” of HVAC work support item.
NOTE:
• When
−3.0°C (−6°F) is corrected on the temperature setting set as 25.0°C (77°F) the temperature controlled
by A/C auto amp. is 25.0
°C (77°F) −3.0°C (−6°F) = 22.0°C (72°F) and the temperature becomes lower than
the temperature setting.
• When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10
V or less, the setting of the difference between the set temperature and control temperature may be can-
celled.
Inlet Port Memory Function (REC)
INFOID:0000000012200031
DESCRIPTION
• If the ignition switch is turned to the OFF position while the intake switch is set to ON (recirculation), “Per-
form the memory” or “Do not perform the memory” of intake switch ON (recirculation) condition can be
selected.
• If “Perform the memory” was set, the intake switch will be ON (recirculation) when turning the ignition switch
to the ON position again.
• If “Do not perform the memory” was set, the air inlets will be controlled automatically when turning the igni-
tion switch to the ON position again.
HOW TO SET
With CONSULT
Perform the “REC MEMORY SET” of HVAC work support item.
NOTE:
Work support items
Display (
°C)
Display (
°F)
TEMP SET CORRECT
3.0
6
2.5
5
2.0
4
1.5
3
1.0
2
0.5
1
0 (initial status)
0 (initial status)
−0.5
−1
−1.0
−2
−1.5
−3
−2.0
−4
−2.5
−5
−3.0
−6
Work support items
Display
Setting
REC MEMORY SET
WITHOUT (initial status)
Perform the memory of manual REC
WITH
Do not perform the memory of manual REC (auto control)