Nissan Juke F15. Manual — part 1010
MWI-62
< SYMPTOM DIAGNOSIS >
THE AMBIENT TEMPERATURE DISPLAY IS INCORRECT
THE AMBIENT TEMPERATURE DISPLAY IS INCORRECT
Description
INFOID:0000000012201347
• The displayed ambient air temperature is higher than the actual temperature.
• The displayed ambient air temperature is lower than the actual temperature.
Diagnosis Procedure
INFOID:0000000012201348
NOTE:
Check that the symptom is not applicable to the normal operating condition before starting diagnosis. Refer to
MWI-63, "INFORMATION DISPLAY : Description"
.
1.
CHECK AMBIENT SENSOR SIGNAL CIRCUIT
Check the ambient sensor signal circuit. Refer to
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair harness or connector.
2.
CHECK A/C AUTO AMP. CONNECTION RECOGNITION SIGNAL CIRCUIT
Check the A/C auto amp. connection recognition signal circuit. Refer to
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair harness or connector.
3.
CHECK AMBIENT SENSOR
Perform the part check for the ambient sensor. Refer to
HAC-59, "Component Inspection"
.
Is the inspection result normal?
YES
>> Replace combination meter. Refer to
MWI-64, "Removal and Installation"
NO
>> Replace ambient sensor. Refer to
HAC-94, "Removal and Installation"
.
MWI
NORMAL OPERATING CONDITION
MWI-63
< SYMPTOM DIAGNOSIS >
C
D
E
F
G
H
I
J
K
L
M
B
A
O
P
NORMAL OPERATING CONDITION
INFORMATION DISPLAY
INFORMATION DISPLAY : Description
INFOID:0000000012201349
AMBIENT TEMPERATURE
The displayed ambient temperature on the information display may differ from the actual temperature because
it is a corrected value calculated from the ambient sensor signal by the combination meter. Refer to
"INFORMATION DISPLAY : System Description"
for details on the correction process.
DISTANCE TO EMPTY
The calculated distance to empty may differ from the actual distance to empty if the refueling amount is
approximately 15 (4 US gal, 3-1/4 Imp gal) or less. This is because the refuel control (moves the fuel gauge
needle quicker than normal judging that the driver is refueling the vehicle) is not performing.
MWI-64
< REMOVAL AND INSTALLATION >
COMBINATION METER
REMOVAL AND INSTALLATION
COMBINATION METER
Exploded View
INFOID:0000000012201350
REMOVAL
.
DISASSEMBLY
Removal and Installation
INFOID:0000000012201351
REMOVAL
1. Remove cluster lid A. Refer to
IP-13, "Removal and Installation"
2. Remove the mounting screws of the combination meter.
3. Pull the combination meter straight to disengage resin clips.
(The figure shows the clip positions on the back of the combina-
tion meter.)
CAUTION:
Never damage the front cover.
1.
Front cover
2.
Unified meter control unit
JSNIA3219ZZ
JSNIA3208ZZ
MWI
COMBINATION METER
MWI-65
< REMOVAL AND INSTALLATION >
C
D
E
F
G
H
I
J
K
L
M
B
A
O
P
4. Turn the lower part of the combination meter in the direction of
the arrow to remove the combination meter from the instrument
panel assembly.
CAUTION:
Never damage the front cover.
5. Remove connector to remove the combination meter.
CAUTION:
Never damage the front cover.
INSTALLATION
Install in the reverse order of removal.
Disassembly and Assembly
INFOID:0000000012201352
DISASSEMBLY
1. Disengage the pawls (2 on the sides, 3 on the lower part) of the combination meter.
2. Insert the removal tool into the clearance (in the order of A, B)
between the front cover and the meter control unit. Remove 4
pawls on the upper side of the front cover by turning the tool
while increasing the clearance.
CAUTION:
Wrap the removal tools with protective tape to prevent
scratches.
3. Pull the front cover straight to remove it from the meter control unit assembly.
CAUTION:
Never damage the front cover.
Never touch the pointer and the crystalline liquid.
ASSEMBLY
Install the front cover straight to the meter control unit assembly and engage all the pawl.
CAUTION:
Never damage the front cover.
JSNIA3546ZZ
JSNIA3210ZZ
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.