Nissan Juke (2016 year). Service Repair Manual — part 529
PG-94
< WIRING DIAGRAM >
HARNESS LAYOUT
REAR DOOR HARNESS (RH SIDE)
JRMIC6923GB
Revision: November 2015
2016 JUKE
PG
HARNESS LAYOUT
PG-95
< WIRING DIAGRAM >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
BACK DOOR HARNESS
JRMIC6924GB
Revision: November 2015
2016 JUKE
PG-96
< WIRING DIAGRAM >
HARNESS LAYOUT
Room Lamp Harness
INFOID:0000000012199811
JRMIC6925GB
Revision: November 2015
2016 JUKE
PG
BATTERY INSPECTION
PG-97
< BASIC INSPECTION >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
BASIC INSPECTION
BATTERY INSPECTION
How to Handle Battery
INFOID:0000000012199812
CAUTION:
• If it becomes necessary to start the engine with a booster battery and jumper cables, use a 12-volt
booster battery.
• After connecting battery cables, ensure that they are tightly clamped to battery terminals for good
contact.
• Never add distilled water through the hole used to check specific gravity.
METHODS OF PREVENTING OVER-DISCHARGE
The following precautions must be taken to prevent over-discharging a battery.
• The battery surface (particularly its top) should always be kept
clean and dry.
• The terminal connections should be clean and tight.
• At every routine maintenance, check the electrolyte level.
This also applies to batteries designated as “low maintenance” and
“maintenance-free”.
• When the vehicle is not going to be used over a long period of
time, disconnect the battery cable from the negative terminal. (If
the vehicle has an extended storage fuse switch, turn it off.)
Work Flow
INFOID:0000000012199813
BATTERY DIAGNOSIS WITH EXP-800 NI OR GR8-1200 NI
To diagnose and confirm the condition of the battery, use the following special service tools:
• EXP-800 NI Battery and electrical diagnostic analyzer
• GR8-1200 NI Multitasking battery and electrical diagnostic station
NOTE:
Refer to the applicable instruction manual for proper battery diagnosis procedures.
BATTERY DIAGNOSIS WITHOUT EXP-800 NI OR GR8-1200 NI
Check Electrolyte Level
WARNING:
Never allow battery fluid to come in contact with skin, eyes, fabrics, or painted surfaces. After touch-
ing a battery, never touch or rub your eyes until you have thoroughly washed your hands. If acid con-
tacts eyes, skin or clothing, immediately flush with water for 15 minutes and seek medical attention.
Failure to do this may cause personal injury or damage to clothing or the painted surfaces.
MEL040F
ELA0349D
Revision: November 2015
2016 JUKE
PG-98
< BASIC INSPECTION >
BATTERY INSPECTION
• Remove the cell plug using a suitable tool.
• Add distilled water up to the MAX level.
SULPHATION
•
A battery will be completely discharged if it is left unattended
for a long time and the specific gravity will become less than
1.100. This may result in sulphation on the cell plates.
•
To determine if a battery has been “sulphated”, note its volt-
age and current when charging it. As shown in the figure, less
current and higher voltage are observed in the initial stage of
charging sulphated batteries.
•
A sulphated battery may sometimes be brought back into ser-
vice by means of a long, slow charge, 12 hours or more, fol-
lowed by a battery capacity test.
Specific Gravity Check
NOTE:
Check the charge condition of the battery.
Periodically check the specific gravity of the electrolyte. Keep a close check on charge condition to prevent
over-discharge.
1. Read hydrometer and thermometer indications at eye level.
2. Use the chart below to correct your hydrometer reading accord-
ing to electrolyte temperature.
Hydrometer Temperature Correction
MEL043F
PKIA2353E
MEL042FA
Battery electrolyte temperature [
°
C (
°
F)]
Add to specific gravity reading
71 (160)
0.032
66 (150)
0.028
60 (140)
0.024
54 (130)
0.020
49 (120)
0.016
43 (110)
0.012
38 (100)
0.008
32 (90)
0.004
27 (80)
0
21 (70)
−
0.004
16 (60)
−
0.008
10 (50)
−
0.012
Revision: November 2015
2016 JUKE
PG
BATTERY INSPECTION
PG-99
< BASIC INSPECTION >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
Charging The Battery
CAUTION:
• Never “quick charge” a fully discharged battery.
• Keep the battery away from open flame while it is being charged.
• When connecting the charger, connect the leads first, then turn on the charger. Never turn on the
charger first, as this may cause a spark.
• If battery electrolyte temperature rises above 55
°
C (131
°
F), stop charging. Always charge battery at
a temperature below 55
°
C (131
°
F).
Charging Rates (Standard Charge)
Charging Rates (Quick Charge)
NOTE:
The ammeter reading on your battery charger will automatically decrease as the battery charges. This indi-
cates that the voltage of the battery is increasing normally as the state of charge improves. The charging amps
indicated above refer to initial charge rate.
• If, after charging, the specific gravity of any two cells varies more than 0.050, the battery should be replaced.
4 (40)
−
0.016
−
1 (30)
−
0.020
−
7 (20)
−
0.024
−
12 (10)
−
0.028
−
18 (0)
−
0.032
Battery electrolyte temperature [
°
C (
°
F)]
Add to specific gravity reading
Corrected specific gravity
Approximate charge condition
1.260 - 1.280
Fully charged
1.230 - 1.250
3/4 charged
1.200 - 1.220
1/2 charged
1.170 - 1.190
1/4 charged
1.140 - 1.160
Almost discharged
1.110 - 1.130
Completely discharged
Approximate charge condi-
tion
Charge current (A)
Charge time (h)
Fully charged
5
2
3/4 charged
2.5
1/2 charged
5
1/4 charged
7.5
Almost discharged
9
Completely discharged
10
Approximate charge condi-
tion
Charge current (A)
Charge time (h)
Fully charged
—
—
3/4 charged
13
0.5
1/2 charged
26
1/4 charged
Almost discharged
Completely discharged
—
—
Revision: November 2015
2016 JUKE
PG-100
< BASIC INSPECTION >
FUSE INSPECTION
FUSE INSPECTION
How To Check
INFOID:0000000012199814
• If fuse is blown, be sure to eliminate cause of malfunction before
installing new fuse.
• Use fuse of specified rating. Never use fuse of more than specified
rating.
• Do not partially install fuse; always insert it into fuse holder prop-
erly.
• Remove fuse for “ELECTRICAL PARTS (BAT)” if vehicle is not
used for a long period of time.
EXTENDED STORAGE FUSE SWITCH (IF EQUIPPED)
The following switch may be mounted on the fuse block (Junction Box) for transportation and storage.
• Remove the extended storage fuse switch when replacing the fuse of extended storage fuse switch.
• Remove the extended storage fuse switch if it causes the interference when the fuse or the other fuses is
checked.
How To Extended Storage Fuse Switch ON/OFF
CAUTION:
• Turn the ignition switch OFF when operating the extended storage fuse switch.
• Under normal conditions, keep the extended storage fuse switch in ON state. Never operate the
extended storage fuse switch except when necessary.
CEL083
1.
Extended storage fuse switch
A.
Type A
B.
Type B
C.
Type C
JSMIA0793ZZ
Revision: November 2015
2016 JUKE
PG
FUSE INSPECTION
PG-101
< BASIC INSPECTION >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
• Type A
- To turn the extended storage fuse switch OFF, pull it up in (A) direction as shown in the figure.
- To turn the extended storage fuse switch ON, press it in (B) direction as shown in the figure.
• Type B
- To turn the extended storage fuse switch OFF, hold (A) of the switch and pull up in (B) direction as shown in
the figure.
- To turn the extended storage fuse switch ON, press it in (C) direction as shown in the figure.
• Type C
- To turn the extended storage fuse switch OFF, pull it up in (A) direction as shown in the figure.
- To turn the extended storage fuse switch ON, press it in (B) direction as shown in the figure.
How To Remove Extended Storage Fuse Switch
Type A
JSMIA0472ZZ
JSMIA0473ZZ
JSMIA0794ZZ
Revision: November 2015
2016 JUKE
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.